background image

The material contained in this document is the property of Electronics & Innovation Ltd., it is subject to 
change without notice.  
 
May 2019                                                                                                                             Revision C 
 

Chapter   1 Introduction 

 

 
The 1000S04 is a broadband solid state amplifier covering the frequency spectrum from 
20  to  400  KHz.  It  is  rated  at  1000  watts  of  RF  power  with  low  harmonic  and 
intermodulation distortion.  A Class D design, the 1000S04 will amplify inputs of AM, FM, 
SSB,  pulse  and  any  complex  modulation  signals  within  the  bandwidth  of  the  amplifier. 
The  amplifier has 60 dB gain, it is unconditionally stable  and will  not  oscillate even with 
combinations  of  mismatched  source  and  load  impedance.  It  is  protected  against  failure 
due to output load mismatch and/or overdrive. 
 
 
 

1.2     INSTRUMENTATION IDENTIFICATION 

 
Each amplifier is identified by a serial number tag on the back panel of the unit. Both the 
model number and the serial number should be quoted to identify specific unit.  
 

1.3      SPECIFICATIONS 

 
Physical and electrical specifications are listed in Table 1-1 below 
 

Содержание 1000S04

Страница 1: ...Ltd it is subject to change without notice May 2019 Revision C 1 1000S04 Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT All operating personnel should use extrem...

Страница 2: ...rts so as to render the unit fully operational such that it performs according to the original specifications free of charge to the original purchaser Should warranty service be required the unit must...

Страница 3: ...of AM FM SSB pulse and any complex modulation signals within the bandwidth of the amplifier The amplifier has 60 dB gain it is unconditionally stable and will not oscillate even with combinations of...

Страница 4: ...240 VAC 50 60 Hz SIZE 3 1 4 X 17 X 21 9 inches 8 27 X 43 4 x 55 7 cm WEIGHT 40 pounds 18 2 kg CONNECTORS N type power BNC sample ports OPERATING TEMPERATURE 0 40 C RACK MOUNTING 2 U Chassis Chapter 2...

Страница 5: ...ction between the supply and the rear of the unit 2 3 1 Proceed as follows i Ensure that there is at least 3 or 7 5 cm clearance at the rear of the unit for air flow ii Connect the output via a 50 ohm...

Страница 6: ...t the output There is a current limit protection circuit to protect the unit in addition to the input drive clamp Current and voltage samples are taken from the output and fed to the BNC connectors on...

Страница 7: ...he equipment being returned for servicing it should be packed in the original shipping carton and packing material If this is not available wrap the instrument in heavy paper or plastic and place in a...

Страница 8: ...ver heat and cause eventual failure if the unit is operated without the cover in place N B Removal of cover will void warranty Ensure that the load is connected to the output prior to connecting the R...

Отзывы: