10
problem
Possible cause
remedy
No power on
The plug on the power
cord is not connected or
is not fully inserted .
The mains fuse is blown
Securely connect the
plug or check the fuse on
the rear panel next to
the socket
No sound
Connecting signal Input
or output cables
incorrect
Check the RCA or XLR
cables and / or the
correct connection
sequence of sources
Distorted sound
The source has an output
signal too high and
preamplifier input is
saturated
Turn down the volume of
the source if it is
equipped with such
control
The signal is low
Switch XLR / RCA on
power amplifier
check the correct
position of the switch for
connecting balanced XLR
or unbalanced RCA
Main fuse is blow
Current overload
replace with identical
fuse. if the fuse blows
again contact service
center
Remote control do not
work
Batteries , objects in
front of receiver
replace batteries or
remove any obstacles in
front of the infrared
receiver
ILP led flashing
Output offset to much
high or power final stage
with problem
Turn off the machine. If
the problem persists,
contact an authorized
service center
Troubleshooting