E15h SPRAYER- Sprayer Setup Operation
3.1
SET THE PRESET RATE 1
Note: This sets the “Main Target” Rate for the sprayer, and activated by the
RATE 1 button on the console.
• Press MENU
• Press ENTER to select SETUP
• Press ENTER to select SPRAYER SETUP.
The focus window will be on
TARGET RATE
• Press ‘RATE 1’ button.
The LED next to the ‘RATE 1’ button will light up.
The current TARGET RATE will be displayed in the window.
• Press ENTER to edit TARGET RATE.
An asterisk (*) should appear after
“TARGET RATE”
• Use Inc/Dec (Up and down arrows) to set the TARGET RATE 1
• Press ENTER to accept the changes
3.2
SET THE PRESET RATE 2
Note: This sets the “2nd Target” Rate for the sprayer, and is activated by the
RATE 2 button on the console.
• Press MENU
• Press ENTER to select SETUP
• Press ENTER to select SPRAYER SETUP.
The focus window will be on
TARGET RATE
• Press RATE 2 button.
The LED next to the RATE 2 button will light up.
The current TARGET RATE will de displayed in the window.
• Press ENTER to edit TARGET RATE.
An asterisk( *) should appear after
“TARGET RATE”
• Use INC/DEC buttons to set the TARGET RATE
• Press ENTER to accept the changes
3.3. MINIMUM FLOW HOLD VALUE
NOTE: This feature alarms the operator when the flow of liquid going through
the flowmeter drops below the value set in the MINIMUM FLOW VALUE.To
switch the MINIMUM FLOW HOLD alarm ON or OFF, go to Section 4.1.1
If this feature is not required, then set the MINIMUM FLOW to ‘0’
• Press MENU
• Press ENTER to select SETUP
• Press ENTER to select SPRAYER SETUP
• Press LINE 1 button to move the focus to MINIMUM FLOW (1)
The current value
is displayed in the window.
• Press ENTER.
An asterisk (*) will be displayed after MINIMUM
• Press INC/DEC buttons, to set the MINIMUM FLOW value.
20
V 1.0 11/05
Содержание KEE E15
Страница 1: ...E15 SPRAYER Operators Manual KEE E15 Horticultural Sprayer Console W117 V1 0 ...
Страница 9: ...Major Topic Heading V 1 2 Personal Notes 9 ...
Страница 10: ...Major Topic Heading V 1 2 Major Topic Heading V 1 2 Personal Notes 10 ...
Страница 38: ...E15h SPRAYER Sprayer Setup Operation 3 32 PRESSURE SENSOR 1 CALIBRATION Pressure Cal Screen 38 V 1 0 11 05 ...
Страница 44: ...E15h SPRAYER Alarm Setup 4 2 SHAFT ALARMS Shaft Alarms Screen 44 V 1 0 11 05 ...
Страница 66: ...E15h SPRAYER Operations Sprayer 7 0 OPERATIONS SPRAYER Working Screen 66 66 V 1 0 11 05 ...
Страница 100: ...E15h SPRAYER Wiring Diagrams Console Pin outs Economy 100 12 1 ECONOMY LOOMS V 1 0 11 05 ...
Страница 101: ...E15h SPRAYER Wiring Diagrams Tractor Loom Economy Looms 101 V 1 0 11 05 ...
Страница 102: ...E15h SPRAYER Wiring Diagrams Sprayer Loom Economy Looms 102 V 1 0 11 05 ...
Страница 103: ...E15h SPRAYER Wiring Diagrams Sprayer Loom Economy Looms 103 V 1 0 11 05 ...
Страница 104: ...E15h SPRAYER Wiring Diagrams Sprayer Loom Economy Looms 104 V 1 0 11 05 ...
Страница 105: ...Personal Notes 105 ...
Страница 106: ...Major Topic Heading V 1 2 Personal Notes 106 ...
Страница 107: ...Major Topic Heading V 1 2 Personal Notes 107 ...
Страница 108: ......