background image

PC BOARD CONNECTIONS

SELECT

EI-2000

ZERO

ZERO

SELECT

GROSS

TARE

REMAIN

LO LEV

CHLORINE

J6

C20

C21

R12

R11

T1

1

2

3

4

CH1

CH2

J4

CH1

LEFT SCALE

CH2

RIGHT SCALE

J5

+E

+S

–S

–E

SH

+E

+S

–S

–E

SH

A

B

C

R

T

IN

RS485

RS232

+L

–L

+R

–R

J3

4-20mA OUT

L

+

R

+

J2

CH1

CH2

RELAYS

G

N

H

J1 POWER

U6

U5

EI-2000

REV 0042

300476

+

1

2

3

4

5

6

7

8

RED

GREEN

WHITE

BLACK

YELLOW

Load Cell Connector

Mating Half P5

(Use for single scale)

LEFT

LEFT

RIGHT

RIGHT

Alarm Contacts

P2

NEUTRAL

HOT

GROUND

AC Power

P1

RED

GREEN

WHITE

BLACK

YELLOW

Load Cell Connector

Mating Half P4

A

B

C

R

T

IN

RS485

RS232

 Com.

Mating Half P6

Analog 4 - 20 mA

Output P3

RIGHT POS.

LEFT POS.

LEFT NEG.

RIGHT NEG.

CONNECTOR PLUGS

EI2000 TRANSMITTER

15' CABLE

AC

CONNECTOR FUNCTION

 J1

POWER IN

120 VAC, 50-60Hz

 J4

LEFT SCALE INPUT

 J5

RIGHT SCALE INPUT

 J3

4-20 mA ANALOG

OUTPUT

 J2

ALARM RELAY OPTION

 J6

SERIAL PORT OPTION

PIN

G

N

H

+E

+S

–S

–E

SH

+E

+S

-S

–E

SH

L+

L–

R+

R–

L

R

A

B

G

R

T

DESCRIPTION

GROUND

NEUTRAL

HOT

+EXCITATION

+ SIGNAL

– SIGNAL

–EXCITATION

SHIELD

+EXCITATION

+ SIGNAL

– SIGNAL

–EXCITATION

SHIELD

LEFT+

LEFT–

RIGHT +

RIGHT –

LEFT ALARM RLY

RT ALARM RLY

RS485 "A"

RS485 "B"

GROUND

RS232 RCV

RS232 XMT

COLOR

RED

WHITE

GREEN

BLACK

YEL

RED

WHITE

GREEN

BLACK

YEL

Содержание DCS302

Страница 1: ...DCS302 DUAL CYLINDER SCALE INSTALLATION OPERATION MANUAL Eagle Microsystems Inc 366 Circle of Progress Pottstown PA 19464 www eaglemicrosystems com phone 610 323 2250 fax 610 323 0114...

Страница 2: ...ndependently and displays the net weight on separate digital indicators Wall mounting bracket and safety chains are optionally available These can adapt to different cylinder sizes All scales are fact...

Страница 3: ...lay Instrument to a suitable and convenient wall surface Remove instrument cover and mount instrument to the wall with 10 screws or suitably sized masonry or hollow wall anchors as applicable The inst...

Страница 4: ...SCALE INSTALLATION 16 30 DCS302 FOOT PRINT 2 1 2 15FT 6 CONDUCTOR CABLE WALL MINIMUM WALL CLEARANCE C L 1 5 8 RECOMMENDED ELEVATION 40 5 5 8 CHLORINE 30 1 2 CLR HOLE 4 PLCS 31 1 2 16 18 30...

Страница 5: ...EI2000 INDICATOR Wall Mounting Dimensions Enclosure conforms to NEMA 4X 7 5 8 5 3 8 ctr to ctr mounting holes 5 5 8 ctr to ctr mounting holes 6 5 8 3 3 16 EI 2000...

Страница 6: ...TE BLACK YELLOW Load Cell Connector Mating Half P4 A B C R T IN RS485 RS232 Com Mating Half P6 Analog 4 20 mA Output P3 RIGHT POS LEFT POS LEFT NEG RIGHT NEG CONNECTOR PLUGS EI2000 TRANSMITTER 15 CABL...

Страница 7: ...Down arrow keys Once the Gross Weight display is set to the known 250 lbs the SEL PB is pressed and the display will change to Weight Remaining and show 150 lbs The weights are removed Readout should...

Страница 8: ...DCS302 DUAL CYLINDER SCALE BASE SPIDER DRAWING 12 15 14 13 48 49 Not Shown 10 1 4 5 2 3 6 7 8 9...

Страница 9: ...SPIDER DRAWING DMS DCS SPIDER ASSEMBLY BASE DISK 36 37 13 41 38 37 39 41 41 42 37 40 38 45 46 44 43 44...

Страница 10: ...closure FG Part of Item 6 above 11 Not used 12 Screw 10B x 5 8 Self tap ss 611060 13 Pivot screw 400229 14 Disc 400178 15 Deck 400178 16 35 Not used 36 Disc washer 400154 37 Perimeter flexure 400143 3...

Страница 11: ...be replaced from the terminal block Loosen the strain relief on the bottom of the divider plate and pull the wire through Load cells and adjustment bolt pictured below for reference Note how high the...

Страница 12: ...o make sure the chain is not twisted Straighten it if needed or the weight readings will not track properly as gas is drained from the cylinder Recalibrate the side with the new load cell This can be...

Отзывы: