background image

1

TABLE OF CONTENTS

SWING GATE OPERATOR SPECIFICATIONS

SAFETY

METHODS OF INSTALLATION

DIAMOND BOARD ADJUSTMENTS AND WIRING

DIAMOND BO

ARD ONL

Y

DIAMOND DC BO

ARD ONL

Y

Standard Installation
Compact Installation
Easy Release Alignment
Gate Arm Installation
Reverse, Phantom (Shadow) and Exit In-Ground Loop Installation
Secondary Entrapment Protection

Requirements for UL 325 Compliant Installation
UL 325 Model Classifications
UL 325 Required Entrapment Protection
Important Safety Information
General Safety Information

Diamond Board
Features Selector Switches #1 - #8
120 VAC Input Power Connection
Setting the Limit Switches
Emergency Release
Adjusting the Clutch
Reset the Motor
Close Timer for a Single or Master Operator
Two-Way Adjustable Reverse Sensor / ERD
Output Connection Descriptions
Global Inputs Descriptions
Radio Receiver Connection
Connecting the Accessories
Diamond Board Master / Slave Setup
Diamond Board Troubleshooting
Eagle-100 / Eagle-200 Models Wiring Diagram
Eagle-100 / Eagle-200 Series Replacement Parts

Pre-Installation Battery Charging
Diamond DC Board
Power Save Mode
Power Fail Operation Switches #1 - #4
Features Selector Switches #1 - #8
P/O Adjust Switches #1 - #4
Power ON/OFF Switch and 5-Pin Primary Plug for Diamond DC Board
Battery Replacement When Necessary
120/240 VAC Input Power Connection
Setting the Limit Switches
Emergency Release
Adjusting the Clutch
Close Timer for a Single or Master Operator
Two-Way Adjustable Reverse Sensor / ERD
Output Connection Descriptions
Global Inputs Descriptions
Radio Receiver Connection
Connecting the Accessories
Diamond DC Board Master / Slave Setup
Diamond DC Board Troubleshooting
Eagle-100-DC / Eagle-200-DC 120 VAC Input Models Wiring Diagram
Eagle-100-DC / Eagle-200-DC 240 VAC Input Models Wiring Diagram
Eagle-100-DC / Eagle-200-DC Series Replacement Parts

6
6
7
7
8
8

9
9

10
10
11
11
11
12
12
12
13
13
14
15
16
17
18

3
4
4
5
5

2

3

6

9

DIAMOND DC BOARD ADJUSTMENTS AND WIRING

19

© 2013 Eagle Access Control Systems, Inc.

All rights reserved. No part of this manual may be reproduced in any means: graphics, electronics or mechanical. Including photocopying 
without the expressed written permission of the publisher. Materials components and specifications are subject to change without notice.

19
19
19
20
20
21
21
21
22
22
23
23
24
24
24
25
25
26
27
28
29
30
31

Содержание 100 Series

Страница 1: ...erators Eagle 100 Series Eagle 100 Series Eagle 200 Series Eagle 200 Series TM ACCESS CONTROL SYSTEMS INC Made in the USA UL 325 Compliant UL 991 Compliant BY EAGLE ACCESS CONTROL SYSTEMS INC Diamond Control Board or Diamond DC Control Board ...

Страница 2: ......

Страница 3: ...amond DC Board Power Save Mode Power Fail Operation Switches 1 4 Features Selector Switches 1 8 P O Adjust Switches 1 4 Power ON OFF Switch and 5 Pin Primary Plug for Diamond DC Board Battery Replacement When Necessary 120 240 VAC Input Power Connection Setting the Limit Switches Emergency Release Adjusting the Clutch Close Timer for a Single or Master Operator Two Way Adjustable Reverse Sensor ER...

Страница 4: ...t 20 ft Model Motor s Power Max Length Max Weight Control Board Operation Battery Back Up Cycles Model Motor Power Max Length Max Weight Control Board Operation Battery Back Up Cycles BY EAGLE ACCESS CONTROL SYSTEMS INC 18 5 16 28 BY EAGLE ACCESS CONTROL SYSTEMS INC 22 17 5 29 25 NOTE The number of gate cycles when using ONLY battery back up power are approximate and WILL vary depending on length ...

Страница 5: ...er under around or through the gate to operate the controls Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use 7 The Stop and or Reset button must be located in the line of sight of the gate Activation of the reset control shall not cause the operator to start 8 A minimum of two 2 WARNING SIGNS shall be installed one on each side of the gate where easil...

Страница 6: ...gs such as airport security area or other restricted access locations not servicing the general public in which unauthorized access is prevented via supervision by security personnel Entrapment Protection Requirements for Each UL 325 Classification Proper installation must satisfy the entrapment protection chart as shown The installation must have one PRIMARY means and a SECONDARY means of entrapm...

Страница 7: ...th local building codes Install warning signs on BOTH sides of the gate Eagle swing gate operators are for vehicular use only They are NOT for pedestrian use Be sure to mount ALL gate operating devices at least ten feet 10 away from any moving part of the gate They must NOT be able to be operated reaching through the gate Regarding Ornamental Grill Styled Gates Injuries may be avoided if a mesh sc...

Страница 8: ...han 35 inches then compact installation is necessary Hinge Center Hinge Center Hinge Center Hinge Center Concrete Pad Concrete Pad Closed Gate Closed Gate Open Gate Wall Open Gate A E I F G H 24 B J C D 2 Eagle 100 19 5 Eagle 200 21 75 28 30 32 35 Option 1 Option 2 Option 3 Option 4 27 5 29 5 25 5 29 34 5 36 39 36 42 43 44 45 B C D E 12 12 12 12 A 35 36 Eagle 100 Eagle 200 22 32 11 12 28 25 F G I ...

Страница 9: ...nded and in the locked position when the gate is fully closed Failure to do this could result in serious injury DO NOT allow arms to scissor when the gate is fully open This will put too much stress on the arms and operator when the gate is cycling Gate Attachment Bracket Weld completely around gate attachment bracket AFTER arm measurements have been determined These two gaps should remain even fo...

Страница 10: ...of Groove Loop Feed Eagle Plug In Loop Detector External Loop Detector Loop Feed Drawing NOT to scale 4 4 4 4 Reverse Loop Exit Loop Phantom Loop Shadow Loop Open Gate Entrapment Area 1 1 2 1 4 Backer Rod Sealant Twisted Loop Wire Inside PVC Conduit Separate Power Loop Detector Options Loop Dete cto r EG167 Sensitivity Indicators Pu sh ho ld Res et Sen bu tto n LE D will blink from 1 to 4 tim es R...

Страница 11: ...6 Stop Reverse ON OFF The radio feature allows the transmitter to work as a three button station and is useful for a partial opening If selected the first command will open the gate the second command will stop the gate and the third command will close the gate Switch 7 Alarm Reset ON OFF If the ON position is selected after the five minute Shutdown time period the operator will reset and any inpu...

Страница 12: ...ut power White Neutral input Green Ground input from an approved grounding method 250 ft 14 AWG 400 ft 12 AWG 650 ft 10 AWG 1000 ft 8 AWG 2000 ft 4 AWG CAUTION MASTER OPEN RIGHT BRAKE ON REVERSE LOOP NC ONE PASS STOP REVERSE ALM RST CLOSE TIMER OFF ON SLAVE OPEN LEFT BRAKE OFF REVERSE LOOP NO OPN DLY S OPN DLY M OPN DLY S OPN DLY M ACTIVE OVERLOAD OPENING LIGHT HEAVY ERD STATUS GATE STATUS Eagle D...

Страница 13: ...ver Depending on the weight of the gate clutch slippage may occur Typical clutch slippage is about 1 4 turn If it does not slip re adjust the clutch accordingly There is a red reset button on top of the 115 VAC motor If the motor ceases to function TURN THE POWER OFF AND ALLOW THE MOTOR TO COOL DOWN then press the reset button These two gaps should remain even for proper fit Diamond Board ONLY ...

Страница 14: ... force beyond normal range Turn Counter Clockwise for LESS force than normal range The Diamond Control Board has a sensitivity adjustment for the OPENING direction and CLOSING direction of the gate Both MUST be adjusted Adjustment must be made so that the gate stops and reverses when meeting an obstruction equal to approximately 20 lbs of stopping force NOTE See page 15 for master slave close time...

Страница 15: ...sition 7 CLOSE Momentary or continuous signal Once activated the gate will fully close Activation while the gate is opening will cause the gate to stop Activating the gate again will close the gate 8 EDGE SENSOR Momentary or continuous signal This signal is active when the gate is opening and or closing If activated when the gate is OPENING The gate will stop pause and reverse in the close directi...

Страница 16: ...ctor 3 Button Station 4 Wire Connection Dry Contact 24 VDC Max Open Close Stop External Reverse Loop Detector Key Switch Lock Box Dry Contact Fire Dept Lock Box Dry Contact Maglock Edge Sensor Photocell Sensor Phone Entry System Separate Power In Ground Reverse Loop In Ground Reverse Loop Separate Power Separate Power In Ground Phantom Loop Shadow Loop Separate Power In Ground Exit Loop Transmitte...

Страница 17: ...y to set the gates closing time 1 60 seconds Use the feature selector to choose 2 3 options for the slave operator Switch 1 MUST be OFF Switch 4 is not used Refer to page 9 for more information about each of the features If NO gate delay is needed Switches 5 8 MUST be OFF Setting the OPEN Delay Feature 5 OPEN DELAY S Turning 5 ON delays opening the SLAVE gate by 1 5 seconds 6 must be turned OFF Th...

Страница 18: ...ion A Motor Overload LED is on B Radio receiver is not ON when the remote control button is activated C The green Power LED is off D The Fuse is blown Feature selector Switch 1 MUST be set to the MASTER ON position unless the operator is being used as a slave operator Safety external loop detector must be connected to the REVERSE LOOP input see pages 13 14 If the CLOSE TIMER feature is desired swi...

Страница 19: ...100 Eagle 200 Models Wiring Diagram Radio ReceiverTerminal Dual Motors Limit Switches Power Switch 115 VAC Outlet 115 VAC Input Eagle 100 Eagle 200 Eagle 200 DM Eagle 200 1HP Orange N O Top Switch Ground Black White Green Red White Black Red Orange Black Gray Gray Gray 2 1 2 Pulley 2 1 2 Pulley 2 Pulley 2 Pulley Red Red Red Blue Green Green Com Black Hot Black 12 Pin Plug 12 Pin Plug 12 Pin Plug 1...

Страница 20: ...e E153 Eagle 200 Sprocket SGR E173 1 2 HP V Belt Single Motor E174 1 HP Dual Motor V Belt E175 Limit Switch Activator E180 Eagle 200 Primary Gear Reducer PGR E182 Eagle 100 Primary Gear Reducer PGR E185 1 2 HP Motor E186 Secondary Gear Reducer SGR E190 Eagle 200 Chassis E191 Control Board Box E192A Eagle 200 Right Chassis Leg E192B Eagle 200 Left Chassis Leg E193 Eagle 200 Leg Bracket E195 Eagle 1...

Страница 21: ... Very Low 2 Low 3 Normal 4 High To change from inductive loop to mini loop see instructions Green Steady indicates power Fast blink Shorted loop Slow blink Open loop Red Detect Indicator EG167 Power Detect Reset Vehicle Detector EG167 Power Detect Reset Vehicle Detector Eagle Plug In Loop Detector Automatically adjusts for proper sensitivity Eagle brand are designed for Fail Safe operation 24 VDC ...

Страница 22: ...escriptions NOTE The power MUST be turned OFF before changing the features selector switches Switch 1 Slave Master Sets the operator to work as Master or Slave Single operator MUST be set to MASTER Switch 2 Gate Opening designates left or right opening direction Switch 3 Motor Brake This switch MUST remain OFF for DC operator The brake feature CANNOT be used for a DC motor Switch 4 Reverse Loop Se...

Страница 23: ... 4 P O ADJUST AC POWER 24VAC SOLAR POWER LOW BATTERY CHARGER ON MH4 DIAMOND DC M S PHASE 0 1 MASTER OPEN RIGHT BRAKE ON REVERSE LOOP NC ONE PASS ON STOP REVERSE ON ALARM RESET ON CLOSE TIMER ON OFF ON 1 ON 2 3 4 5 6 7 8 SELECT ACTIVE OVERLOAD OPENING LIGHT HEAVY ERD STATUS GATE STATUS TIMER MIN MAX CLOSING OPEN LIMIT OPENING CLOSING CLOSE LIMIT CLOSE STOP OPEN SLAVE MASTER 14 13 MAGLOCK 24 VDC 10 ...

Страница 24: ... set so the gate stops at the correct open and close positions the control board MUST have power for the limit LEDs when setting the limit switches Adjust the close limit switch FIRST when the gate is in the closed position Open and Close Limit LEDs will light up on control board for top or bottom limit switches as indicated Indicates the direction the gate is cycling IMPORTANT DO NOT cycle the op...

Страница 25: ... These two gaps should remain even for proper fit 3 Wire 24V RADIO POWER RELAY RELAY RET 3 2 1 4 24V COMMON GROUND 4 Wire 24V RADIO POWER RELAY 24V RET Adjusting the Clutch Depending on the weight of the gate clutch slippage may occur Typical clutch slippage is about 1 4 turn If it does not slip re adjust the clutch accordingly Diamond DC Board ONLY ...

Страница 26: ...ition of the installation A heavier gate will require LESS sensitivity and a lighter gate will require MORE sensitivity Only a qualified service technician must make all adjustments to these sensors Proper function of reverse sensor ERD When meeting an obstruction in the CLOSING direction the gate will STOP reverse direction and return to the FULL OPEN position When meeting an obstruction in the O...

Страница 27: ...signal will cause the gate to begin opening The second signal will close the gate only when the gate is in the fully open position 7 CLOSE Momentary or continuous signal Once activated the gate will fully close Activation while the gate is opening will cause the gate to stop Activating the gate again will close the gate 8 EDGE SENSOR Momentary or continuous signal This signal is active when the ga...

Страница 28: ...r External Exit Loop Detector 3 Button Station 4 Wire Connection Dry Contact 24 VDC Max Open Close Stop External Reverse Loop Detector Key Switch Lock Box Dry Contact Fire Dept Lock Box Dry Contact Maglock Edge Sensor Photocell Sensor Phone Entry System Separate Power In Ground Reverse Loop In Ground Reverse Loop Separate Power Separate Power In Ground Shadow Loop Separate Power In Ground Exit Loo...

Страница 29: ...OT function properly if not wired correctly Use the feature selector to choose 2 8 options for the master operator Switch 1 MUST be ON Refer to page 20 for more information about each of the features Use the Close Timer 8 ON to set the gates closing time 1 60 seconds Use the feature selector to choose 2 3 options for the slave operator Switch 1 MUST be OFF Switch 4 is not used Refer to page 20 for...

Страница 30: ... Motor Overload LED is on B Radio receiver is not ON when the remote control button is activated C The green Power LED is off D The Fuse is blown Feature selector Switch 1 MUST be set to the MASTER ON position unless the operator is being used as a slave operator Feature selector Switch 3 Brake MUST be set to the OFF position Safety external loop detector must be connected to the REVERSE LOOP inpu...

Страница 31: ...8 STOP 5 CLOSE 7 LOOP WIRE INPUT EXIT OPEN SHADOW LOOP REVERSE LOOP COMM PORT OUTPUTS GLOBAL INPUTS RECEIVER RELAY 24VDC RELAY 24VDC 1 REVERSE LOOP SHADOW LOOP EXIT LOOP REVERSE SHADOW EXIT RESET 24 VDC GND CLK GND CLK AC POWER 24VAC SOLAR POWER LOW BATTERY CHARGER ON FUSE MAX 20A FUSE MAX 35A 20 FUSE MAX 20A MOTOR BATTERY 24VAC H N G LEFT RIGHT GND GND LEFT RIGHT 20 SOLAR 1 2 3 OFF OFF OFF 1 ON 2...

Страница 32: ... STOP 5 CLOSE 7 LOOP WIRE INPUT EXIT OPEN SHADOW LOOP REVERSE LOOP COMM PORT OUTPUTS GLOBAL INPUTS RECEIVER RELAY 24VDC RELAY 24VDC 1 REVERSE LOOP SHADOW LOOP EXIT LOOP REVERSE SHADOW EXIT RESET 24 VDC GND CLK GND CLK AC POWER 24VAC SOLAR POWER LOW BATTERY CHARGER ON FUSE MAX 20A FUSE MAX 35A 20 FUSE MAX 20A MOTOR BATTERY 24VAC H N G LEFT RIGHT GND GND LEFT RIGHT 20 SOLAR 1 2 3 OFF OFF OFF 1 ON 2 ...

Страница 33: ...130 Electrical Outlet E131 Power Switch E146 Pulley SGR E147 2 1 2 Motor Pulley E151 Eagle 200 DC Drive Chain Top Position E152 Clutch Kit Complete E153 Eagle 200 DC Sprocket SGR E173 V Belt E175 Limit Switch Activator E180 Eagle 200 DC Primary Gear Reducer PGR E182 Eagle 100 DC Primary Gear Reducer PGR E186 Secondary Gear Reducer SGR E190 Eagle 200 DC Chassis E191 Control Board Box E192A Eagle 20...

Страница 34: ...32 NOTES ...

Страница 35: ...33 NOTES ...

Страница 36: ... 91342 Copyright 2013 Eagle Access Control systems Inc All rights reserved Toll Free 1 800 708 8848 Phone 818 837 7900 Fax 818 837 7911 www eagleoperators com Swing Gate Operators Eagle 100 Series Eagle 100 Series Eagle 200 Series Eagle 200 Series Made in the USA Eagle 100 200 Swing Revision E ...

Отзывы: