SERVICING THE FILTER
SERVICING THE VAC MOTOR
PERIODIC MAINTENANCE
(Every six to twelve months):
1. Check filter for wear, replace dirt saturated filters that
do not respond to normal cleaning.
2. Inspect gasket seals and replace those which have
begun to leak.
Examine carbon motor bruhes and commutator.
The filter is accessed by lifting the head assembly off the tank.
Cartridge filters - Remove the filter retainer by turning the black knob 90 degrees counter-clockwise.
Cartridge filter will then slide off.
NOTE
:
Be sure to frequently clean the filter
Worn filters can affect vacuum performance. Replace the filter when it becomes worn out and
norman cleaning will not restore vac performance.
1. Disconnect power cord from power source.
2. To access the vac motor, remove the screws that attach the main cover to the head
assembly and set the cover to one side.
3. Disconnect the motor’s 2 red lead wires from the main switch.
4. Disconnect green/yellow wire by removing screws from motor core.
5. Remove the four motor mounting screws.
6. Remove motor plate and set aside.
7. Take out the motor and remove the upper and lower gaskets.
8. Inspect gaskets. If they show any wear or tear in the material, replace.
9. Install gaskets onto new motor. Make sure gaskets are properly seated.
10. Install the new motor. Make sure foam mufflers are positioned properly.
11. Attach motor plate to motor.
12. Connect green/yellow wire to motor core.
13. Connect motor’s 2 red lead wires to main switch.
14. Re-assemble vac cover.
15. Test for proper operation
Page 6
Содержание Hospital S6101HQ-S
Страница 5: ...Page 3...