Description
This d
t and its contents are the property of CASSIDIAN
nd must not be copied or circul
1
2
3
4
5
2.4.5.4
Converters
2.4.5.4.1 Primary convertor
The primary convertor provides the power supplies necessary to the IDR IDO 3G
sub-assemblies (see Figure 2.13).
The convertor is powered on/off using the “I/O” switch on the front panel (see Plate 6.IV,
item 2 or 9).
2 types of convertor (at the choice of the command) to power the IDR IDO 3G:
• by the 100-240 V AC, 50-60 Hz mains,
• by an external 12-24 V DC direct power supply (limits 10.8 V to 31.2 V).
The AC/DC or DC/DC conversion circuit carries out the cutting, rectification, filtering and
regulation to provide a per 12 V direct voltage and + 48 V remote controlled by
the synchronisation board.
A 6.3 AT fuse (not accessible) located inside the convertor provides protection for the
primary convertor.
Additional protection mechanisms protect the convertor against overvoltages and
interfering pulses on input, short circuits and currents that are too high on output, as well as
in temperature.
2
Figure 2.13
PRIMARY CONVERTOR BLOCK DIAGRAM
T
°
"I/O"
Distribution and
protections
+ 48 V
+ 12 V
3G PA-TRX module,
SYNCHRO board
SYNCHRO
board
Supervision
Power supply
input
IDR-
IDO
_MC2
_CON
VER
T
IS
S
E
URS-
P
RIM_S
Y
NO
P_
01_0
2
OFF
Содержание CASSIDIAN IDR IDO 3G
Страница 5: ...DEFENDING WORLD SECURITY IDR IDO 3G Technical Manual TMO PS11209BENAB01 07 2012...
Страница 150: ...IDR IDO 3G_MC9_IDR IDO_FAV_PRES_01_01 3 1 2 4 5 7 6 8 9 10 11 15 14 13 12 18 17 16 Plate 6 II IDR IDO 3G FRONT PANEL...
Страница 152: ...1 7 2 3 4 5 IDR IDO 3G_MC9_IDR IDO_3 4 AR OUVERT_PRES_01_01 6 Plate 6 III IDR IDO 3G INTERNAL VIEW...
Страница 154: ...1 2 3 4 5 6 7 8 9 10 11 RIP IDO 3G_MC2_LED_ALIMENTATION_FAV_01_01 Plate 6 IV IDR IDO 3G PRIMARY MAINS OR DC CONVERTERS...
Страница 163: ......
Страница 164: ...MC2 RR APP 00033 02 02 EN...