EACON EC620 Скачать руководство пользователя страница 27

  F u n c t i o n C o d e T a b l e

EC620

 

8.Standard wiring diagram

External braking 

resistor

External 

DC reactor

Short

circuit 

plate

Note4

EC620

AC

 

POWER

INPUT

Circuit 

breaker

MCCB

Contactor

MC

Input 

reactor

Output 

re a c t o r

A

N

A

L

O

G

I

N

P

U

T

G r o u nd r e s istance < 1 0

Ω

Shield e d c ab l e

C lo s e to A C dr iv e 

gro un d term i nal )

D
I
G
I
T
A
L

I
N
P
U
T

Factory short circuit, 24V port 

maximum output

DC24V

/

100mA

Note2

Forward RUN

Reverse RUN

Forward JOG

Reverse JOG

Coast to stop

Fault reset

Frequency up(UP

))

Frequency down(DW

))

Note:1. The function 

in brackets 

descriptions 

        

the factory value of AC drive;

are 

     2. Opticalcoupler isolation, compatible 

        ambipolarity input;

     3. Input impedance: 2.4kΩ;

     4. Voltage range at electrical level input: 

        9V

30V

      Shielded twisted pair

Close to AC drive ground terminal

Note

1. Maximum output current of 10V port

10mA

         resistance range of potentiometer

1K

Ω~

5K

Ω;

      2. Input voltage range of AI1 port

DC 0V

10V

         input impedance

22K

Ω;

    

  3. A12/AI3 port determines voltage or current 

         input by P5-00 function parameter, input range

:

         (0V

10V

)/(

0/4mA

20mA

);

input impedance

22K

Ω

 

         for voltage input

500

Ω

 for current input.

      Shielded twisted pair

Close to AC drive ground terminal

Legend

1. Symbol   represents the main circuit terminal;

     

   2. Symbol   represents control circuit terminal.

High-speed 

pulse output

      Shielded twisted pair

Close to AC drive ground terminal

Coil

Coil

      Shielded twisted pair

Close to AC drive ground terminal

Coil

      Shielded twisted pair

Close to AC drive ground terminal

Coil

High-speed 

pulse input

Note3

Note

:

 The voltage or current output of AO1

/

AO2 

port is determined by P5

-

32 function parameters,

and the output range is (0V

10V

)/(

0mA

20mA

)

.

Note1

 

Note

:

Maximum output of Y1

/

Y2 port

:

 AC250V/3A,

      DC24V/5A

    

  Maximum output of Y3

/

Y4 port

:

 DC24V/50mA.

D
I
G
I
T
A
L

I
N
P
U
T

A
N
A
L
O
G

I

N

P

U

T

S t a n d a r d w i r i n g d i a g r a m

EC620

 

4 9

 -

50

 -

R

R

S

T

R

S

T

-

+

1

PR

+

2

U

V

W

U

V

W

M

24V

PLC

S1

S2

S3

S4

S5

S6

S7

S8

COM

10V

AI1

AI2

AI3

GND

AO1

A02

GND

GND

Y3

Y4

YC

PLC

AC200V

ACOV

ACOV

AC200V

Y1A

Y1B

Y1C

Y2A

Y2C

HDI

HDO

U

-

39

U

-

40

Auxiliary frequency 

Y value

-

-

-

-

2137H

2138H

U

-

41

U

-

42

U

-

43

U

-

44

U

-

45

Remaining 

running time

-

-

MPPT maximum power reference voltage

 

Q=QN*f/FN unit:m³/h

This function code shows the high level of 

the total flow of the water pump. 

Unit: 10000 cubic meters

-

-

-

-

-

2139H

213AH

213BH

213CH

213DH

U

-

46

This function code shows the low level of 

the total flow of the water pump. 

Unit: 0.1m³

-

213EH

Press PRG key for 2 seconds continuously to enter the U monitoring parameter group item.

*

VF separation V

VF separation F

PV reference 

voltage

Current flow 

of water pump

High level of total 

flow of water pump

Low level of total 
flow of water pump

U

-

38

Main frequency 

X value

-

-

2136H

U

-

35

U

-

36

Rated current 

Software version 

-

-

-

-

2133H

2134H

U

-

37

Communication 

frequency 

-

-

2135H

Содержание EC620

Страница 1: ...Drive Manufacturer EC620 Solar Pump AC Drive Electronic instruction Professional AC Drive Manufacturer ZHEJIANG EACN ELECTRONIC TECHNOLOGY CO LTD Address No 1 Jinhe Road Qinshan Street Haiyan County J...

Страница 2: ...arameters 7 5 P4 Input Terminals Function 7 6 P5 Analog Terminal Parameters 7 7 P6 Start Stop Control Parameters 7 8 P7 System Configuration Parameters 7 9 P8 Auxiliary Functions 7 10 P9 Fault and Pro...

Страница 3: ...pply is cut off but the indicator light of the mani pulator of AC drive is still on there is still high voltage in the AC drive which is very dangerous please do not touch the interior circuit and com...

Страница 4: ...ignal PLC needs to be connected to external power supply and be disconnected from 24V power supply terminal 1 Input voltage range DC 0V 10V 2 Impedance 22k 1 Input range DC 0V 10V 4mA 20mA decided by...

Страница 5: ...he startup operation is performed on the rotating motor 7 A sudden load is added during acceleration 8 The AC drive model is of too small power class 1 The output circuit is grounded or short circuite...

Страница 6: ...power input is abnormal 2 The drive board is faulty 3 The lightening board is faulty 4 The main control board is faulty 1 Eliminate external faults 2 Seek technical support 3 Seek technical support 4...

Страница 7: ...erform the motor autotuning 3 Set P9 40 and P9 41 correctly based on the actual situation 7 Function Code Table Function Code Table EC620 Faults and solutions EC620 P0 Standard Parameter group 0000H A...

Страница 8: ...Restore default setting 0017H 3 6 Undefined 7 Initialization setting User data reset 10 Back up current user parameters 210 Restore user backup parameters 0 210 P1 Motor parameters Setting Range Func...

Страница 9: ...eleration process of AC drive the overexcitation control can restrain the rise of bus voltage and avoid over voltage fault The larger the overexcitation gain the stronger the suppression effect 64 020...

Страница 10: ...the gain is the more obvious the suppression of the oscillation is When using the vibration suppression function the motor rated current and no load current parameters shall be accurate otherwise the...

Страница 11: ...rence ability is but the slower the response speed is the shorter the filtering time is the weaker the anti interference ability is but the faster the response speed is Filter time of terminal S1 S4 0...

Страница 12: ...put signal selection AI1 input voltage minimum value BIT2 AI3 signal selection 0 0 10V 1 0 20 00ma BIT3 S8 enable HDI function 0 General switch function 1 HDI high speed pulse input function 0 00 10 0...

Страница 13: ...0 200 0 Used to adjust the value of analog output of AO1 terminal 10 0 10 0 Used to adjust the zero point of the AO1 terminal output signal 100 0 0 0 P5 35 P5 36 P5 37 0523H 0524H 0525H 100 0 0 0 0 20...

Страница 14: ...vibration when the machine starts stops After setting the S word characteristic time the accelera tion and deceleration time will only extend 1 2 of the S word characteristic time at the beginning and...

Страница 15: ...nly BIT0 0 Stop 1 Run BIT1 0 Forward RUN 1 Reverse RUN BIT2 Reserved BIT3 Reserved AC drive status before power off P7 18 0712H Read only P8 Auxiliary Functions Function Code Parameter Name Setting Ra...

Страница 16: ...of the AC drive The start up of the timer is completed by the external timer trigger terminal of the timer The timing starts from the reception to the external trigger signal After the timing time arr...

Страница 17: ...HASE_INPUT 13 ERROR_LOSE_PHASE_OUTPUT 14 ERROR_OH_MODULE 15 ERROR_EXTERNAL EQUIPMENT 16 ERROR_COMMUNICATE 17 ERROR_CONTACTOR 18 ERROR_CURRENT_DETECTION 19 ERROR_AUTO TUNING 20 ERROR_ENCODER 21 ERROR_E...

Страница 18: ...at instantaneous rise action 0 50s 0924H returns to normal the AC drive will acce lerate to the set frequency The basis for judging whether the bus voltage returns to normal is that the bus voltage is...

Страница 19: ...the specification of no hardware detec tion input phase failure the input phase failure is detected by the change amplitude of bus voltage When the change amplitude of bus voltage is greater than P9...

Страница 20: ...tial output PA 13 PID differential limit 0 10 0A0DH 0 00 650 00s PID given change time refers to the time required for PID given value to change from 0 0 to 100 0 PA 14 PID setting change time 0 00s 0...

Страница 21: ...tion proportion setting Communication response delay 3 N 8 2 No check data format 8 stop bit 2 4 E 8 2 Even parity check data format 8 stop BIT 2 5 0 8 2 Odd Parity check data format 8 stop BIT 2 0 00...

Страница 22: ...Multi frequency 9 0D09H PD 09 Multi frequency 10 0D0AH PD 10 Multi frequency 11 0D0BH 0 0 PD 11 Multi frequency 12 0D0CH 0 0 PD 12 Multi frequency 13 0D0DH 0 0 PD 13 Multi frequency 14 0D0EH 0 0 PD 14...

Страница 23: ...ence 8 0D27H 0000 PD 39 Running direction and acceleration deceleration time of PLC reference 9 0D28H 0000 PD 40 Running direction and acceleration deceleration time of PLC reference 10 0D29H 0000 PD...

Страница 24: ...12 100 00 2 00 100DH A0 13 Reserved 1009H A0 09 Minimum Error KP1 It determines the regulation intensity of the whole PID regulator The greater the P value is the greater the regulation intensity is...

Страница 25: ...will be cleared and restored to the operation state 75 0 101AH A0 26 Full water level detection delay code is still valid when the switch value is full of water 5s 101BH A0 27 Wake up delay at full w...

Страница 26: ...ers read only U Setting Range U Monitoring Parameters Function Code Parameter Name Default Address U 00 2110H Set frequency 1E00H AE 00 Timing time 1 AE Scheduled operation Parameters The three sets o...

Страница 27: ...put Shielded twisted pair Close to AC drive ground terminal Coil Coil Shielded twisted pair Close to AC drive ground terminal Coil Shielded twisted pair Close to AC drive ground terminal Coil High spe...

Страница 28: ...bias voltage and the factory value 24V port and PLC port are short circuited 3 Port S8 is restricted by function parameter P5 00 which can be used as high speed pulse input channel with maximum input...

Страница 29: ...ication Number Distributor Contacts Date of delivery Address No 1 Jinhe Road Qinshan Street Haiyan County Jiaxing City Zhejiang Province Website www eacon cn E mail overseas eacon cc Warranty Service...

Отзывы: