25

26

Steps to view the menu of the Detail Info.:

1) Enter the password:

Please contact your inverter supplier for the default password. When finishing

password entering, press ENT to verify the password. If the password is

correct, the sub-menu will be displayed, and if wrong, the LCD will display

‘Wrong Password’ and return to the previous menu. Press ESC to return to

the main menu.

2) Access the sub-menu:

After enter the correct password, the 6 sub-menus will be displayed:

1.

Operation Info, 2. Fault Info, 3. Warning Info, 4. SW Version, 5. Rated

Power, 6. Rated Voltage, 7. Daily Energy, 8. Monthly Energy, 9. Yearly Energy,

10. Export Total, 11. Export Today

Press UP/DOWN to scroll the screen, press ENT to go into the selected

sub-menu and press ESC to return to the main menu.

6.2.4.1 Operation Information

This information is for maintenance personnel to get the operation

information, and the information is as below:

No.

Display

Duration

Explanation

1

10 S

This menu indicates:
GFCI RMS:

Leakage current

protection

ISO:

Ground

fault

protection/Insulation Resistance

2

10 S

This menu indicates:
The temperature of heat sink of
inverters

3

10 S

This menu indicates:
Inverter inner temperature

4

10 S

This menu indicates:
Bus voltage
AC direct component

5

10 S

This menu indicates:
Power factor ratio
Output power limit

6

10 S

This menu indicates:

Residual current protection
Insulation

Resistance/Ground

fault protection

7

10 S

This menu indicates:
All PV in parallel mode
MPPT shadow mode

8

10 S

This menu indicates:
Self examination of AC relay
Output

direct

component

protection

9

10 S

This menu indicates the apparent
power

10

10 S

This menu indicates the active
power

11

10 S

This menu indicates the reactive
power

NEXT = ENT EXIT = ESC
Password: 0000

GFCI RMS:

10 mA

ISO

: 1.25 k

Ω

Heatsink

Temp

65.5

Inv

Inner

Temp

45.0

BusVol:

385.5V

DCI : 0 mA

PF:+1.00 ac
Pac Limit:

80%

RCD(GFCI):

ON

PVISOGuard:

ON

AllPVParal:

ON

MPPTShadow:

RelayCheck:OFF
DCI Prot : ON

Apparent

Power

2000 VA

Active

Power

2000 W

Reactive

Power

2000 Var

Содержание EES10K-M1

Страница 1: ...energy com Each Energy Technology Suzhou Co Ltd Address No 8 Building No 38 of Beiguandu Road Yuexi Street Wuzhong District Suzhou Jiangsu Province China Tel 8651266581088 Email service eachenergy com...

Страница 2: ...ontents 1 About the Manual 3 2 Product Overview 4 3 Safety 7 4 Mounting 8 4 1 Installation Location 8 4 2 Inverter Mounting 9 5 Electrical Connection 11 5 1 DC Side Connection of Inverters 11 5 2 AC S...

Страница 3: ...vities marked in this document under the guidance of safety instructions Please read this manual carefully before conducting any kind of work on the inverters Valid Region This manual applies to the o...

Страница 4: ...FF The inverter has not been connected to the Internet ALARM ON Alarm or fault has been detected OFF The inverter is operating normally 2 3 Scope of Delivery No Description Quantity 1 Inverter 1 2 Wal...

Страница 5: ...nverters must be performed by qualified technicians and be in compliance with applicable electrical standards regulations and the requirements of local power authorities Wear protective equipment for...

Страница 6: ...tilt is allowed If more than one inverter are installed in one location a minimum 150 mm clearance should be kept between two inverters and a minimum 300 mm clearance between inverters and the ground...

Страница 7: ...C switch OFF 3 Connect the DC connectors to the Inverter small click confirms connection Please guarantee the correct polarity of the connection DANGER ELECTRICAL SHOCK Lethal high voltage will be gen...

Страница 8: ...up screws on the connectors with socket head wrench and pull back wires to ensure firm connection 4 Connect the Cable Gland Seal Ring Housing and Terminal Block together a small click confirms secure...

Страница 9: ...s recommended to install a breaker over current protection device OCPD to protect the AC grid connection conductors The table below is the recommended parameter of an OCPD ratings for the Inverter 5 6...

Страница 10: ...and to realize export power management The suggested parameter Max input current for meter 120A Max measuring current for CT 100A Detail specifications of meter and CT can be found on Each Energy Web...

Страница 11: ...ording to the international conventional method 2 Plug the RJ45 connector to the DRM port of the inverter Power rate limit modes as required by AS NZS 4777 2 2020 is supported in this inverters When a...

Страница 12: ...Month total energy generated this month Last Month total energy generated last month 3 10 S This Day total energy generated today Previous Day total energy generated yesterday 4 10 S DC voltage1 the...

Страница 13: ...will display the screen as below Press ENT to move the cursor from left to right Press UP DOWN to select a number for a selected digit Press ESC to save the setting and return to the main menu 6 2 3...

Страница 14: ...below No Display Duration Explanation 1 10 S This menu indicates GFCI RMS Leakage current protection ISO Ground fault protection Insulation Resistance 2 10 S This menu indicates The temperature of hea...

Страница 15: ...The software version or firmware version of the inverter is displayed and is accessible for technicians only 6 2 4 5 Rated Power The rated power of the inverter is displayed here 6 2 4 6 Rated Voltage...

Страница 16: ...f AC output frequency 6 To set up the low limit of AC output frequency 7 To set up the max generation power 8 To set up the AC instant voltage limit 9 To set up the power control 10 To set up the incr...

Страница 17: ...to the previous menu 6 2 5 3 AC Output Voltage Limit This section is to set up the high and low limit of AC output voltage as permitted by local grid company if the grid voltage is beyond the range sp...

Страница 18: ...e to frequency disturbance is available in those inverters Procedures to set up the gradient of power rate limit Step1 Go to All Set Enable in the menu of TECHNICAL SET and turn the status to ON Step2...

Страница 19: ...shifting the frequency of the inverter away from nominal conditions in the absence of a reference frequency frequency shift It is enabled by default 6 2 5 8 2 Volt var Response Mode The QU Curve is e...

Страница 20: ...res to enable or disable the Volt var Response Mode Step1 go to All Set Enable in the menu of TECHNICAL SET and turn the status to ON Step2 go to Special Func and then go to QU Curve Step3 enable or d...

Страница 21: ...e power mode may be enabled in some situations by the electrical distributor to meet local grid requirements one of these modes shall be enabled if the volt var mode is disabled Procedures to set up t...

Страница 22: ...ess ENT to perform the selection and press ESC to return to the previous menu 6 2 5 14 Export Limit The inverter s export limit can be achieved together with external devices such as a CT or meter The...

Страница 23: ...t exceeds the hardware protection limit 1 Restart the inverter 2 Decrease solar panels quantity in parallel if it occurs repeatedly 4 Bus Over Voltage Soft Transient bus voltage exceeds the software p...

Страница 24: ...mpany 16 Over Temperatu re Export reduction due to over temperature 1 Check the ventilation of installation environment 2 Avoid direct sunlight 17 GFCI Device Fault Fault in current leakage testing de...

Страница 25: ...small replace it with a larger size cable 2 Adjust the protection value limit as permitted by the grid company 28 Grid Freq Out Range Grid frequency is out of range Adjust the protection value limit t...

Страница 26: ...49 50...

Отзывы: