1.  Introduction

The optional Ethernet interface provides a network connection in form of a standard RJ45 Ethernet port, plus a stan-

dard RS232 port. They can only be used alternatively, whereas the data transmission speed of the RS232 is much 

slower compared to the Ethernet port, because the RS232 is working at 9600 baud. Time-critical measurements are 

thus only advised to be performed using the Ethernet port. The Ethernet option offers a set of features which are, 

caused by the different designs of our PS series, not identical with every model. The table gives an overview, which 

series can provide which functionality in combination with the Ethernet interface.

 PS series

Uset Iset Pset Umon Imon CC/CV/CP OVP OT

Output

on/off

 PS 9000 Mod. 2004

 1,5...9kW

x

x

x

x

x

x x

x

 HV 9000

x

x

x

x

x

(1

x

 

x = feature present

(1 = only CC/CV

Meaning of the abbreviations:

Uset       - Set the set value for voltage

Iset       - Set the set value for current

Umon     - Read out (=measure) the actual voltage

Imon      - Read out (=measure) the actual current

CC/CV/CP  - Operation mode CC (Constant Current) or CV (Constant Voltage), as well as CP (Constant Power)

 

 

 

 

   Note: these modes exclude each other, that means only one can be active 

 

 

 

 

   A logical 1 (=high) means that it is active (in combined modes a 1 means CC active and a 0 that CV is active)

OVP      - Query alarms, in this case overvoltage protection (is logical 1, as long as OVP is present)

OT       - Query alarms, in this case overtemperature protection (is logical 1, as long as OT is present)

1.1 Basic items to know for operation

Important! Read this before first use!

• 

When sending a command the first time after the device has been powered, the power supply will automatically 

switch to external control and the set values for current and voltage are set to zero.

• 

Current and voltage have to be set both during remote control. It means, you can’t set voltage externally via the 

Ethernet interface and current on the front of the device with the potentiometer, for example.

• 

Activating the „Local“ switch on front panel (where present) interrupts remote control as long as the switch is acti-

vated. The device switches to manual control and it does not reset the interface card.

Attention!

Activating switch „Local“ while the DC output is on can result in unwanted voltage leaps, because the 

device switches to manual control and thus the voltage/current settings from the potentiometers on the 

front become instantly effective.

• 

The Output On/Off switch for the DC power output can not be overridden by the command OUTP, that means if the 

switch is pressed, i.e. output = off, and external control is active, the unit will not put out voltage (does not apply to 

PS 9000 models from 2004 or later).

• 

Models with power adjustment, like a PS 9000 from 2004 or later, definitely require a power set value which is not 

provided by the interface. It it thus required to define the power set value via the analogue interface on the rear, 

either by a potentiometer resp. external voltage (pin 1, with reference to pin 14) or by a bridge between pin 1 and 

pin 18 (which will define the power to 100%).

• 

All SCPI commands can also be set via the RS232 port. In order to use the RS232 for remote control, the IP 

programming procedure has to be canceled by denying the question „Program IP address?“. After this, all SCPI 

commands can be used as normal via RS232.

Attention!

The RS232 port is not galvanically isolated to the PC! Before connecting this port, either for IP program-

ming or normal remote control, make sure that the PC and the power supply are on the same potential.

Description

Содержание HV 9000

Страница 1: ...Bedienungsanleitung Operation manual Ethernet Interface PS 9000 HV 9000 Art Nr 61100104...

Страница 2: ......

Страница 3: ...steuerung verlassen 7 5 SCPI Programmierung 8 5 1 SCPI Befehle 8 5 2 Standard IEEE Befehle 8 5 3 Zuweisung der Meldesignale bei Abfrage mit STAT QUES 9 English Page 1 Introduction 11 1 1 Basic items t...

Страница 4: ...e Abweichung vom vorgegebenen Wert Sollwert und tats chlichem Wert Istwert Dieser Fehler ist bedingt durch Toleranzen aller Bauteile die an der Erzeugung von Sollwerten bzw der Messung von Istwerten b...

Страница 5: ...den auf Null gesetzt Die Leistung kann von der Schnittstelle nicht gestellt werden und mu daher an der analogen Schnittstelle vorgegeben werden Siehe unten Strom und Spannung m ssen bei Fernsteuerung...

Страница 6: ...sse zu bernehmen Hinweis Solange das Ger t ber serielles Kabel am RS232 Port zum PC verbunden ist zum Programmieren der IP Adresse oder zur Fernsteuerung ist der Ethernetport inaktiv 3 1 1 Programmier...

Страница 7: ...4 1 Fernsteuerung aktivieren Die Fernsteuerung mu nicht explizit mit einem bestimmten Befehl aktiviert werden Jeder beliebige erste Befehl au er RST nach dem Einschalten des Ger tes oder nach einem R...

Страница 8: ...Netzger tes in Volt VOLTage Meldet den zuletzt programmierten Wert der Spannungswert zur ck kein Istwert Beispiel VOLT 5 5 Setzt 5 5V Ausgangsspannung am Netzger t Beispiel VOLT Fragt den zuletzt gese...

Страница 9: ...senes Bit ist 1 Signal inaktiv oder nicht verdrahtet zugewiesenes Bit ist 0 Folgende Zuordnung f r PS9000 neu 1 5 9kW HV9000 Bit 0 1 2 CP 3 4 OT 5 Mains OK 6 OVP 7 CC CV CC CV Die Bedeutung der Signal...

Страница 10: ...et value and the true value actual value on the output This is error comes from the sum of tolerances of any component that is involved in the output value generation or actual value measuring The err...

Страница 11: ...ered the power supply will automatically switch to external control and the set values for current and voltage are set to zero Current and voltage have to be set both during remote control It means yo...

Страница 12: ...is serial cable connection between the RS232 port of the device and a PC either for IP program ming or normal remote control the Ethernet port remains deactivated 3 1 1 Programming the IP address via...

Страница 13: ...he new IP address can be accessed now 4 Remote control Remote control of the power supply is basically dedicated to the Ethernet port and via network connection 4 1 Activating remote control Remote co...

Страница 14: ...e of the programmed voltage this is not an actual value Example VOLT 5 5 Sets 5 5V output voltage at the power supply Example VOLT Queries the most recent set value CURRent value Programs the output c...

Страница 15: ...als can be queried at which model Following generally applies Signal active assigned bit is 1 Signal inactive or not wired assigned bit is 0 Following assignment applies for PS9000 1 5 9kW HV9000 Bit...

Страница 16: ...EA Elektro Automatik GmbH Co KG Entwicklung Produktion Vertrieb Helmholtzstra e 31 33 41747 Viersen Telefon 02162 37 85 0 Telefax 02162 16 230 ea1974 elektroautomatik de www elektroautomatik de...

Отзывы: