background image

CONTENTS

Page

1 Thank You For Buying Stellar

. . . . . . . . . . . . . . . . . . . . . . . .

5

2 Care of the Control Unit

. . . . . . . . . . . . . . . . . . . . . . . . . .

5

2.1 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

2.2 Handling

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

2.3 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

2.4 Cleaning

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

3 Installation Considerations

. . . . . . . . . . . . . . . . . . . . . . . . .

6

3.1 Mounting

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

3.2 RF Connections

. . . . . . . . . . . . . . . . . . . . . . . . . . .

6

3.3 Cooling Considerations . . . . . . . . . . . . . . . . . . . . . . . . .

6

3.4 Interface Connections

. . . . . . . . . . . . . . . . . . . . . . . . .

6

4 Operation of the Control Unit

. . . . . . . . . . . . . . . . . . . . . . . .

6

4.1 Applying The Voltage Supply

. . . . . . . . . . . . . . . . . . . . . .

6

4.2 The Amplifier Search Process

. . . . . . . . . . . . . . . . . . . . . .

6

4.3 Warm-up

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

4.4 Standby

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

4.5 Transmit

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

4.6 Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

4.7 Fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

5 Measurement and Monitor Functions

. . . . . . . . . . . . . . . . . . . . .

8

5.1 Power (watts)

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

5.2 Power (dBW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

5.3 Helix Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

6 Gain Setting (Only available on the N6081D)

. . . . . . . . . . . . . . . . . .

8

6.1 Set Gain (result in watts)

. . . . . . . . . . . . . . . . . . . . . . . .

8

6.2 Set Gain (result in dBW)

. . . . . . . . . . . . . . . . . . . . . . . .

8

7 Amplifier Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

7.1 Introduction

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

7.2 Interconnections (see also Appendix A)

. . . . . . . . . . . . . . . . . .

9

7.3 Interconnections for -01 variant (see also Appendix B) . . . . . . . . . . . . .

9

7.4 Termination Resistors

. . . . . . . . . . . . . . . . . . . . . . . . .

9

8 Fault Finding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

9 Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

9.1 Electrical

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

9.2 Mechanical

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

9.3 Environmental

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

10 Related Document

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

page 4

HBN6081-1

Содержание N6081 series

Страница 1: ...N6081 Series Operation Manual...

Страница 2: ......

Страница 3: ...e2v technologies N6081 Series Operation Manual e2v technologies 2004 HBN6081 1 Issue 5 January 2004 186 3591...

Страница 4: ...RF connectors must be correctly fitted before operation so that there is no leakage of RF energy The control unit must not be operated unless the RF output connection is correctly terminated It is par...

Страница 5: ...2v technologies quality management system is certificated to the requirements of ISO 9001 CUSTOMER CARE Stellar 24 Hour Hotline In the event of a Stellar product fault or urgent application enquiry di...

Страница 6: ...Warm up 7 4 4 Standby 7 4 5 Transmit 7 4 6 Off 7 4 7 Fault 7 5 Measurement and Monitor Functions 8 5 1 Power watts 8 5 2 Power dBW 8 5 3 Helix Current 8 6 Gain Setting Only available on the N6081D 8...

Страница 7: ...n Storage temperature range is from 740 to 70 8C Do not use control unit boxes to support the weight of any other item Retain the control unit boxes for future use Avoid severe shocks 2 2 Handling The...

Страница 8: ...The N6081 is used to control an amplifier from the following product series N61xx e g N6132D N6150D N63xx e g N6312 N6318D N64xx e g N6440 4 1 Applying The Voltage Supply The N6081 requires no externa...

Страница 9: ...r 180 seconds the XMIT LED will light and the WARM UP LED will go out The amplifier will operate Amplifier fan will rotate at full speed Display will now show the output power in watts If the XMIT key...

Страница 10: ...et Gain result in watts This feature can be selected by pressing the function select button once more This will allow the digital attenuator to be set on the amplifier This is achieved by turning the...

Страница 11: ...ions see also Appendix A 41 way amplifier 15 way D type connector connector A 2 B 4 C 3 D 5 E 6 H P R p 14 J 7 K 8 L 9 U 1 b 10 c 11 d 13 e 12 Notes Cable for b and c must be a twisted pair Cable for...

Страница 12: ...voltage 15 V current 100 mA 9 2 Mechanical Dimensions 19 inch rack width 483 mm 19 inches height 1U 44 mm 1 73 inches depth 50 mm 2 inches depth with allowance for connectors and bend radius of cable...

Страница 13: ...120R 1 4W 120R 1 4W 120R 1 4W Appendix A 41 way Stellar 15 way D type Amplifier connector Controller connector A 2 B 4 C 3 D 5 E 6 H 14 J 7 K 8 L 9 P R U 1 b 10 c twisted pairs 11 d 13 e 12 p...

Страница 14: ...7 5 4 19 2 25 9 24 23 21 22 20 1 3 10 11 12 13 14 15 16 17 18 26 9 WAY D SOCKET SK1 1 2 3 4 5 6 7 8 9 OFF S O WARM UP LED STDBY LED XMIT LED FAULT S O OFF SWITCH STDBY SWITCH XMIT SWITCH Vin 15 V RX R...

Страница 15: ...transmit mode 18 Other see comments 24 RF load too hot 9 No output power 25 LV PSU fault 10 Other see comments 26 Bad HV rail Difficulties With Control Panel Or Remote Interface 27 Set up 31 Hour cou...

Страница 16: ......

Страница 17: ...F 91572 BIE VRES Cedex Telephone 331 6019 5500 Facsimile 331 6019 5529 USA e2v technologies inc 4 Westchester Plaza Elmsford NY 10523 1482 Telephone 914 592 6050 Facsimile 914 592 5148 Canada e2v tech...

Отзывы: