background image

©

 e2v technologies (uk) limited 

103959 

DAS709758AA (UK) version 6, page 6 

1.3 Camera 

Features 

 

• 

Dynamic Scene Colourisation (DSC) 

 The 

Argus

TM

4 provides the end-user with a selection of colour palettes, which 

colourises the thermal image to allow the user to pinpoint the hottest areas 
within the fire scene. 

 

These colour palettes are: 

 

Grey Scale (White Hot) 

  Basic white-hot greyscale, expanded to cover the dynamic range of the 

scene with no colourisation. 

 

Grey Scale (Black Hot) 

  Basic black-hot grey scale, expanded to cover the dynamic range of the 

scene with no colourisation. 

 

Heat-Finder Red (White Hot) 

  Basic white-hot grey scale, expanded to cover the dynamic range of the 

scene with red colourisation of the hottest part of the scene.

 

 

Heat-Finder Red (Black Hot) 

  Basic black-hot grey scale, expanded to cover the dynamic range of the 

scene with red colourisation of the hottest part of the scene. 

 

Heat-Finder Soft Red (White Hot) 

  Basic white-hot grey scale, expanded to cover the dynamic range of the 

scene with yellow to red colourisation of the hottest part of the scene. 

 

Heat-Finder Soft Red (Black Hot) 

  Basic black-hot grey scale, expanded to cover the dynamic range of the 

scene with yellow to red colourisation of the hottest part of the scene. 

 

Heat Marker Red 

  Basic white-hot grey scale, expanded to cover the dynamic range of the 

scene with a gradient of red colourisation above 150 

°

C. 

 

Heat Marker Soft Red 

  Basic white-hot grey scale, expanded to cover the dynamic range of the 

scene with a gradient of yellow through to red colourisation above 150 

°

C.

 

 

Half Colour 
A limited colour scheme that expands to cover the dynamic range of the 
scene. 

 

Full Colour 1 
A full colour scheme that expands to cover the dynamic range of the scene.

 

Содержание Argus 4

Страница 1: ...User s Manual Manuel d Utilisation Benutzerhandbuch Manuale Utente Manual del Usuario Anv ndarhandbok...

Страница 2: ...maintenance section of this manual Neglecting the above may result in injury or death CAUTIONS Never point the camera at a source of extreme temperature e g the sun as this can damage the detector e2v...

Страница 3: ...ting Notes 10 2 Remote Control Functions 12 3 Rechargeable Battery Pack and Battery Charger 14 3 1 Rechargeable Battery Pack 14 3 2 Battery Charger 15 4 Cleaning Maintenance and Replaceable Parts 17 5...

Страница 4: ...ke and in darkness Detect and display the relative temperatures of objects within the scene Locate the seat and spread of the fire Move swiftly in search and rescue of casualties Have the ability to s...

Страница 5: ...Battery Release Button 2 Battery 6 Side Strap 3 USB Data Lead Socket 7 Ambient Temperature Sensor 4 Front Bumper 8 Removable Handle 1 2 3 4 5 6 7 8 9 10 11 1 Date 7 Time 2 Spot Temperature Target 8 Tr...

Страница 6: ...on and for approximately 5 seconds a start up screen will be displayed on the camera screen while the system performs a self test routine This start up screen is end user configurable The thermal imag...

Страница 7: ...ck hot grey scale expanded to cover the dynamic range of the scene with red colourisation of the hottest part of the scene o Heat Finder Soft Red White Hot Basic white hot grey scale expanded to cover...

Страница 8: ...g the software provided Note If the object in the scene does not fully fill the target marks then a false reading may be obtained Different materials have differing surface emissivities which will pro...

Страница 9: ...range for this mode is up to 400 C 750 F o Extended Low Sensitivity Mode M If the scene has extreme temperatures the ArgusTM 4 will automatically switch to Extended Low Sensitivity mode indicated by...

Страница 10: ...of the battery display The camera will continue to operate at this temperature but the user may see some degradation of the image quality If the user ignores this warning and continues to operate the...

Страница 11: ...be burning or smouldering behind doors in ducting or in wall or floor cavities In such circumstances the operator should look for areas that appear whiter when compared with the surroundings For exam...

Страница 12: ...must be taken to ensure that the image seen is not simply a reflection Experience will give the operator added confidence Control of Water Streams Jets When viewed through the camera water streams fro...

Страница 13: ...ain will set any changes required and exit the option list or pressing the menu or menu buttons another option can be selected The menu will disappear from the image after 8 seconds Time and Date Sett...

Страница 14: ...n be scrolled through until the image required to be deleted is selected Press the delete button twice to delete image LCD Brightness Adjustment By pressing the or buttons the LCD brightness is increa...

Страница 15: ...Battery Pack The ArgusTM 4 camera is supplied with two rechargeable battery packs The rechargeable packs are designed to power an ArgusTM 4 for 4 hours from a full charge and use Nickel Metal Hydride...

Страница 16: ...ng 3 2 Battery Charger Warnings The charger has been designed for indoor use only and should not be exposed to water or dust Do not cover the charger while in use The charger is turned on once connect...

Страница 17: ...will go into maintenance mode and the LED will show green It is recommended that the battery be removed from the charging shoe once charged Before fitting another battery into the charger allow at le...

Страница 18: ...idate the warranty THERE ARE NO OTHER USER SERVICEABLE PARTS Handle P7030HA To remove the handle spin the large thumbwheel anti clockwise until the handle detaches from the camera body Refitting is th...

Страница 19: ...EC Environmental Data Thermal conditions The camera has been designed to operate for 45 minutes at 80 C 176 F 15 minutes at 150 C 302 F 7 minutes at 260 C 500 F 5 minutes at 260 C 500 F Argus TM 4 HR...

Страница 20: ...130 Focal distance 1 m to infinity optimised at 4 m 3 feet to infinity optimised at 13 feet Horizontal aperture f 1 0 Field of view 50 horizontal Viewing Display type Transflective active matrix colou...

Страница 21: ...56 Charger Power requirements 100 240 VAC 50 60 Hz 1 A max Length 105 mm 4 inches nominal Width 65 mm 2 5 inches nominal Height 35 mm 1 4 inches nominal Net weight 220 g 0 1 pounds nominal Operating t...

Страница 22: ...is contract THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY AND IS STRICTLY LIMITED TO THE TERMS HEREOF e2v SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR OF F...

Страница 23: ...was encoded by a customer engaged in a personal and non commercial activity and or was obtained from a video provider licensed by MPEG LA to provide MPEG 4 video No license is granted or shall be imp...

Страница 24: ...4 Westchester Plaza Elmsford NY 10523 1482 USA Telephone 914 592 6050 Facsimile 914 592 5148 e2v technologies sas 16 Burospace F 91572 Bi vres Cedex France Telephone 0 16019 5500 Facsimile 0 16019 552...

Отзывы: