Document No. IS 5001      Issue D                     11-09-07                      

Sheet 2 of 6

 

3) 

The  equipment  is  only  certified  for  use  in  ambient 

temperatures  in  the  range  -40

o

C  to  +60

o

C  and 

should not be used outside this range. 

4) 

The  certificate  number  has  an 

X

  suffix,  which 

indicates  that  the  certificate  contains  one  of  more 

special  conditions  for  safe  use.  Those  installing  or 

inspecting the equipment should refer to this section 

of the certificate. 

5) 

The equipment has not been assessed as a safety-

related  device  (as  referred  to  by  Directive  94/9/EC 

Annex II, clause 1.5). 

6) 

Installation of this equipment shall be carried out by 

suitably-trained personnel in accordance with the 

applicable code of practice. 

7) 

Repair of this equipment shall only be carried out by 

the manufacturer or in accordance with the 

applicable code of practice. 

8) 

The certification of this equipment relies on the 

following materials used in its construction: 

 

 

 

Enclosure:

 

ABS Plastic

 

 

 

 

If the equipment is likely to come into contact with 

aggressive substances, then it is the responsibility of 

the user to take suitable precautions that prevent it 

from being adversely affected, thus ensuring that the 

type of protection is not compromised. 

 

Aggressive substances

 - e.g. acidic liquids or 

gases that may attack metals, or solvents that may 

affect polymeric materials. 

 

Suitable precautions

 - e.g. regular checks as part 

of routine inspections or establishing from the 

material

s data sheet that it is resistant to specific 

chemicals. 

 

 

SPECIAL CONDITIONS FOR SAFE USE (as stated in the 

EC Type Examination Certificate SIRA 05ATEX2084X)

 

Conditions for IS-mAl Sounder 

 

The  equipment  has  an  ingress  protection  rating  of  IP65. 

However, if it has been supplied without cable entry devices, 

then the user shall ensure that the devices that are fitted will 

provide  an  ingress  protection  that  is  appropriate  to  the 

environment in which it is installed i.e. IP20 or better. If only 

one of the two cable entries are used, then the unused entry 

'knockout' shall be left intact or fitted with a blanking device 

that  ensures  ingress  protection  appropriate  to  the 

environment in which it is installed i.e. IP20 or better. 

 

The total capacitance connected to ter wrt - (i.e. the 

capacitance of the cable plus any other capacitance) shall 

not exceed 83nF. 

 

The  equipment shall not be directly installed in any process 

where its enclosure might be electro-statically charged by the 

rapid flow of a non-conductive media. 

 

The  equipment  shall  only  be  supplied  via  Terminals  +  w.r.t. 

Terminals  -  from  a  barrier  having  a  maximum  open  circuit 

voltage Uo that is < 28V and a maximum short circuit current 

Io that is < 93mA, where Io is resistively limited. The barrier 

shall be ATEX certified by a notified body. 

 

 

4.2  Zones, Gas Groups and Temperature Classification 

The IS-mA1 minialarm sounder has been certified EEx ia IIC 

T4.  When  connected  to  an  approved  system  it  may  be 

installed in: 

 

 

 

Zone 0  explosive gas air mixture 

 

continuously present. 

 

Zone 1  explosive  gas  air  mixture  likely  to  occur  in 

normal operation. 

 

Zone 2  explosive gas air mixture not likely to occur, 

and if it does, it will only exist for a short time. 

 

Be used with gases in groups: 

 

 

 

Group A 

propane 

 

Group B 

ethylene 

 

Group C 

hydrogen 

 

Having a temperature classification of: 

 

T1 

450

º

T2 

300

º

T3 

200

º

T4 

135

º

 

4.3  Ter and - 

Power  is  supplied  to the  sounder  via the  +  and 

  terminals 

which have the following input safety parameters: 

 

 

Ui 

28V 

 

Ii 

93mA 

 

Pi 

  660mW 

 

 

Ci = 0  Li = 0 

 

The IS-mA1 sounder may be powered from an ATEX certified 

Zener  barrier  or  galvanic  isolator  which  have  output 

parameters  equal  to  or  less  than  28V,  93mA  and  660mW,

 

where  Io  is  resistively  limited.  The  cable  parameters  stated 

on  the  selected  Zener  barrier  or  galvanic  isolator  certificate 

must be observed. 

 

U

p  to  three  IS-mA1  sounders  can  be  connected  in  parallel 

and powered from a common barrier or isolator. Connecting 

two sounders in parallel will reduce the output from each by 

about  3dB.  Three  sounders  should  only  be  powered  from a 

common  supply  when  the  maximum  supply  voltage  is 

available. 

 

4.4  Terminals S2 and S3  

When terminals S2 or S3 are connected to 0V (- terminal) the 

sounder  output  tone  changes  to  the  second  or  third  stage 

alarm  respectively.    The  input  safety  parameters  for  these 

terminals are: 

 

 

Ui 

28V 

 

 

Ii 

0mA  

 

Because the permitted input current is zero, these terminals 

may  only  be  connected  to  a  diode  return  barrier,  an 

intrinsically safe relay or a galvanic isolator, all of which must 

have been certified by an EC Notified Body. Only diode return 

barriers with a voltage drop of less than 0.9V may be used. 

Alternatively, these terminals may be connected directly to a 

mechanically activated switch within the hazardous area. 

 

 

 

 

 

 