background image

Series
Module [s]

EOL Module [e]

Product
Option [o]

GNEXCP6B-BG[s][t][l][e][m][d][v][o][x][u]-[v][e][s]

Product
Version [v]

LED Indicator [u]

Switch Type [s]

Terminals [t]

GNExCP6B/C/D/E CALL POINTS

2S

EUROPEAN SAFETY SYSTEMS LTD

IMPRESS HOUSE

MANSELL ROAD

ACTON

LONDON W3 7QH

WWW.E2S.COM

C

THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE 

MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND 

IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY 

SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY 

BE DISCLOSED, LOANED, COPIED OR USED FOR 

MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR 

WRITTEN CONSENT.

EUROPEAN SAFETY SYSTEMS LTD.

AS PER LATEST DATE OF ISSUE SHOWN ABOVE

DRAWING TO BS8888:2000

GEOMETRIC TOLERANCES TO ISO1101:1983

LINEAR DIMENSIONAL TOLS

ANGULAR DIMENSIONAL TOLS

STANDARDS

MOD No.

REASON - INITIAL - DATE

ISSUE

DATE

APPROVED

CHECKED

DATE

DATE

DRAWN

WEIGHT (Kg)

SURFACE FINISH

MATERIAL

ALTERNATIVE MATERIAL

SHEET

SCALE

TITLE

A3

IF IN DOUBT, ASK - 

DO NOT SCALE

ALL DIMENSIONS IN MM

DRAWING NUMBER

A

B

C

D

E

F

G

10

9

G

F

E

7

8

6

5

D

C

1

3

4

2

A

B

D154-06-051

D.HOWGILL

R.N.POTTS

R.N.POTTS

07-02-20

OF

GNExCP6B/C/D/E-BG/PB/PT MANUAL 

CALL POINT WIRING SCHEMATIC

NTS

6

6

07-02-20

07-02-20

SEE SHEET 1

D.A.H - 17-11-2022

4

SEE SHEET 1

D.A.H - 06-07-2021

3

ACN0077

2

SEE SHEET 1

D.A.H - 28-08-2020

warning signals

Module Device Codes

EOL

Series

Resistor

ExxxR

SxxxR

Diode

ED1

SD1

Zener Diode

ExxxZ

SxxxZ

LED

N/A

L or C

Circuit shown in Unoperated condition

Unoperated condition
(Glass Intact / Standby Condition)

Te (2,3) & -(4,5) M/S 1 & M/S 2 open
Ter(2,3) & (6) M/S 1 & M/S 2 closed

Operated condition
(Glass Broken / Button pushed in)

Te (2,3) & -(4,5) M/S 1 & M/S 2 closed
Ter(2,3) & (6) M/S 1 & M/S 2 open

Circuit shown in Unoperated condition

Unoperated condition
(Glass Intact / Standby Condition)

Ter(3,4) & -(5,6) M/S 1 & M/S 2 open
Ter(3,4) & (7) M/S 1 & M/S 2 closed

Operated condition
(Glass Broken / Button pushed in)

Ter(3,4) & -(5,6) M/S 1 & M/S 2 closed
Ter(3,4) & (7) M/S 1 & M/S 2 open

Circuit shown in Unoperated condition

Unoperated condition
(Glass Intact / Standby Condition)

Ter(3,4) & -(5,6) M/S 1 & M/S 2 open
Ter(3,4) & (7) M/S 1 & M/S 2 closed

Operated condition
(Glass Broken / Button pushed in)

Ter(3,4) & -(5,6) M/S 1 & M/S 2 closed
Ter(3,4) & (7) M/S 1 & M/S 2 open

DUAL MICROSWITCHES IN PARALLEL | LED

CONFIG. 24

CONFIG. 23 DUAL SWITCH WITH EOL & SERIES DEVICE

DUAL SWITCH WITH SERIES DEVICE

CONFIG. 22

DUAL SWITCH WITH EOL DEVICE

CONFIG. 21

DUAL SWITCH WITH LED

4
-

EOL

2
+

Y

M/S 2

R

B

M/S 1

M/S 1 & M/S 2

E

O

L

 1

-

8

7

6

5

4

3

2

1

R

Y

B

S

E

R

IE

S

 1

Y

Y B

8

7

6

5

4

3

2

1

R

B

-

+ +

-

-

+

+

S

E

R

IE

S

3
-

2
+

8

7

6

5

4

3

2

1

S

E

R

IE

S

3
-

EOL

2
+

-

-

+

+

+

2/3 4/5

-

2/3 4/5

-

+

DEVICE POLARITY

ZENER
DIODE

DIODE

3/4

2

3/4

2

DIODE

ZENER
DIODE

DEVICE POLARITY

+

+

DIODE

ZENER
DIODE

DEVICE POLARITY

+

-

5/6

3/4

-

-

5/6

3/4

-

+

3
+

5
-

3
+

5
-

3
+

5
-

-

-

M/S 1 & M/S 2

M/S 1 & M/S 2

SWITCH TYPE [s]

PRODUCT OPTION [o]

LED INDICATOR [u]

[D]

[P]

[L]

Dual

Parallel Wiring

LED

SWITCH TYPE [s]

PRODUCT OPTION [o]

LED INDICATOR [u]

EOL MODULE [e]

[D]

[P]

[L]

[Exxxx]

Dual

Parallel Wiring

LED

EOL Device

SWITCH TYPE [s]

TERMINALS [t]

PRODUCT OPTION [o]

LED INDICATOR [u]

SERIES MODULE [s]

[D]

[D]

[P]

[L]

[Sxxxx]

Dual

DIN Rail Only

Parallel Wiring

LED

Series Device

SWITCH TYPE [s]

TERMINALS [t]

PRODUCT OPTION [o]

LED INDICATOR [u]

MODULE [e][s]

[D]

[D]

[P]

[L]

[Exxxx][Sxxxx]

Dual

DIN Rail Only

Parallel Wiring

LED

EOL + Series

LED

R

L

1

Circuit shown in Unoperated condition

Unoperated condition
(Glass Intact / Standby Condition)

Te (2,3) & -(4,5) M/S 1 & M/S 2 open
Ter(2,3) & (6) M/S 1 & M/S 2 closed

Operated condition
(Glass Broken / Button pushed in)

Te (2,3) & -(4,5) M/S 1 & M/S 2 closed
Ter(2,3) & (6) M/S 1 & M/S 2 open

4
-

2
+

Y

M/S 2

B

M/S 1

M/S 1 & M/S 2

-

8

7

6

5

4

3

2

1

R

Y

B

-

+ +

3
+

5
-

LED

R

L

1

LED

LED

LED

M/S 2

M/S 1

R

L

1

R

S

E

R

IE

S

 1

Y

Y B

R

B

M/S 2

M/S 1

R

L

1

R

E

O

L

 1

LED

SHEET 6

R

Notes:
1. LED available only on GNExCP6B and GNExCP6C Units
2. GNExCP6C Units have the option to remove the LED current-limiting resistor RL1
using LED option 'C'. In all other cases, RL1 is included.  

Содержание GNExCP6C-PB

Страница 1: ...by SIRA and have been approved to the following standards EN60079 0 2018 IEC60079 0 2017 EN60079 1 2014 IEC60079 1 2014 EN60079 7 2015 IEC60079 7 2017 EN60079 18 2015 IEC60079 18 2014 EN60079 31 2014...

Страница 2: ...ent Limitations The maximum allowable current is determined as the smallest value from the following scenarios 1 When both module resistor values are the same as or above the minimum range of values s...

Страница 3: ...EC EN61508 which has been assessed and is considered suitable for use in low demand safety function Random Hardware Failures and Systematic Failures route 2H As an unvoted item i e hardware fault tole...

Страница 4: ...DED CONFIG 8 AND 12 ADDED LED ONLY CONFIG 13 REMOVED CONFIGS RE NUMBERED 1 TO 24 4 warning signals Circuit shown in Unoperated condition Unoperated condition Glass Intact Standby Condition Terminals 2...

Страница 5: ...cuit shown in Unoperated condition Unoperated condition Glass Intact Standby Condition Terminals 1 2 M S 1 and 4 5 M S 2 open Terminals 1 3 M S 1 and 4 6 M S 2 closed Operated condition Glass Broken B...

Страница 6: ...ng signals Circuit shown in Unoperated condition Unoperated condition Glass Intact Standby Condition Terminals 2 3 4 5 open Terminals 2 3 6 closed Operated condition Glass Broken Button pushed in Term...

Страница 7: ...he LED current limiting resistor RL1 using LED option C In all other cases RL1 is included Circuit shown in Unoperated condition Unoperated condition Glass Intact Standby Condition Terminals 2 3 M S 1...

Страница 8: ...S 1 M S 2 open Terminals 2 3 6 M S 1 M S 2 closed Operated condition Glass Broken Button pushed in Terminals 2 3 4 5 M S 1 M S 2 closed Terminals 2 3 6 M S 1 M S 2 open Circuit shown in Unoperated co...

Страница 9: ...rated condition Glass Broken Button pushed in Terminals 3 4 5 6 M S 1 M S 2 closed Terminals 3 4 7 M S 1 M S 2 open Circuit shown in Unoperated condition Unoperated condition Glass Intact Standby Cond...

Страница 10: ...surance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 2813 CSA Group Netherlands B V Utrechtseweg 310 681...

Страница 11: ...and electronic equipment including amendment by Directive 2015 863 EU Regulation EC 1907 2006 Registration Evaluation Authorisation and Restriction of Chemicals REACH The product and all the componen...

Страница 12: ...t GNExCP6A GNExCP6B GNExCP6C GNExCP6D GNExCP6E II 2G Ex db eb IIC T6 Gb 40 C Ta 70 C II 2D Ex tb IIIC T75 C Db 40 C Ta 70 C or II 2G Ex db eb mb IIC T4 Gb 40 C Ta 50 C II 2D Ex tb IIIC T80 C Db 40 C T...

Страница 13: ...ity Other Standards and Regulations EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP code enclosure rated IP66 On behalf of European Safety Systems Ltd I declare that on the date...

Отзывы: