background image

 

 
 
 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

 

www.e2s.com

 

Tel: +44 (0)208 743 8880

 

Document No. D211-00-601-IS

 

Issue 1

 

20-08-22

 

 

Sheet 1 of 8

 

 

INSTRUCTION MANUAL 

D2xC2 Alarm Horn and Strobe 
For use in Hazardous Locations

 

 

 

D2XC2X05 
D2XC2X10 

 
1)  Product Table 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

2)  Warnings 
 

 DO NOT OPEN WHEN AN EXPLOSIVE 

ATMOSPHERE IS PRESENT 

 DO NOT OPEN WHEN ENERGISED 

 POTENTIAL ELECTROSTATIC CHARGING 

HAZARD - CLEAN ONLY WITH A DAMP 
CLOTH 

 HIGH VOLTAGE SHOCK HAZARD. WAIT 5 

MINUTES AFTER REMOVING POWER 
BEFORE OPENING THE ENCLOSURE 
 

Avertissement: 

 NE PAS OUVRIR UN PRESENCE 

D’ATMOSPHERE EXPLOSIVE 

 NE PAS OUVRIR ENERGIE 

 DANGER POTENTIEL CHARGE 

ÉLECTROSTATIQUE - NETTOYER 
UNIQUEMENT AVEC UN CHIFFON HUMIDE 

 HAUT TENSION, RISK DE CHOC. ATTENDEZ 

5 MINUTES APRES AVOIR DEBRANCHE 
L’ALIMENTATION AVANT D’OUVRIR LA 
BOITIER 

 

Model 

Nominal Voltage 

Beacon 
Current 

Sounder 

Current

 

D2xC2X05DC024 

20-28Vdc 

296mA

 

313mA 

D2xC2X05DC048 

48Vdc 

145mA

 

181mA 

D2xC2X05AC115 

115-120Vac 50/60Hz 

80mA 

 

89mA 

D2xC2X05AC230 

220-230Vac 50/60Hz 

30mA

 

52mA 

D2xC2X10DC024 

20-28Vdc 

609mA

 

313mA 

D2xC2X10DC048 

48Vdc 

260mA

 

181mA 

D2xC2X10AC115 

115-120Vac 50/60Hz 

185mA

 

89mA 

D2xC2X10AC230 

220-230Vac 50/60Hz 

107mA

 

52mA 

Table 1: Electrical Ratings 

Содержание D2xC2 Series

Страница 1: ...WER BEFORE OPENING THE ENCLOSURE Avertissement NE PAS OUVRIR UN PRESENCE D ATMOSPHERE EXPLOSIVE NE PAS OUVRIR ENERGIE DANGER POTENTIEL CHARGE ÉLECTROSTATIQUE NETTOYER UNIQUEMENT AVEC UN CHIFFON HUMIDE HAUT TENSION RISK DE CHOC ATTENDEZ 5 MINUTES APRES AVOIR DEBRANCHE L ALIMENTATION AVANT D OUVRIR LA BOITIER Model Nominal Voltage Beacon Current Sounder Current D2xC2X05DC024 20 28Vdc 296mA 313mA D2x...

Страница 2: ...a 40 C to 50 C Class III Div 1 2 Ta 40 C to 50 C D2xC2 X05DC048 X05AC115 X05AC230 Class I Div 2 ABCD T3 Ta 40 C to 50 C Class II Div 2 FG T5 Ta 40 C to 50 C Class II Div 2 FG T6 Ta 40 C to 40 C Class III Div 1 2 Ta 40 C to 50 C D2xC2 X10DC048 X10AC115 X10AC230 Class I Div 2 ABCD T2B Ta 40 C to 50 C Class II Div 2 FG T5 Ta 40 C to 50 C Class II Div 2 FG T6 Ta 40 C to 40 C Class III Div 1 2 Ta 40 C ...

Страница 3: ...test issue of the following standards EN60079 14 IEC60079 14 Explosive atmospheres Electrical installations design selection and erection EN60079 10 1 IEC60079 10 1 Explosive atmospheres Classification of areas Explosive gas atmospheres EN60079 10 2 IEC60079 10 2 Explosive atmospheres Classification of areas Explosive dust atmospheres 5 Special Conditions for Safe Use Special Condition for safe Us...

Страница 4: ...For use in explosive dust atmospheres a minimum ingress protection rating of IP6X must be maintained For use in explosive gas atmospheres a minimum ingress protection rating of IP54 must be maintained NPT stopping plugs should be greased before insertion 8 Cable Connections Electrical connections are to be made into the terminal blocks on the PCBA located in the enclosure See section 6 of this man...

Страница 5: ...End Of Line Monitoring DC Units Only On D2xC2 DC units dc reverse line monitoring can be used if required All DC units have a blocking diode fitted in their supply input lines An end of line monitoring resistor can be connected across the ve and ve terminals If an end of line resistor is used it must have the following values Min Resistance Min Power 24V DC 3 9KΩ 0 5W 1KΩ 2W 48V DC 15KΩ 0 5W 3 9KΩ...

Страница 6: ...fixing holes of the guard lens cover and housing Refit the fixings to hold into place the fixings MUST be fitted in the order shown above 15 DIP Switch Please note that the D2xC2X05DC024 D2xC2X10DC024 beacon PCBAs have a DIP Switch that is NOT customer configurable This should only ever be set to 00 Fig 12 DIP Switch setting 00 16 Maintenance Overhaul Repair Maintenance repair and overhaul of the ...

Страница 7: ... 0 5s off x3 1s gap ISO 8201 Temporal Pattern 0 1 0 1 0 0 44 1 8 12 1000Hz 0 5s on 0 5s off x3 1s gap ISO 8201 Temporal Pattern 1 1 0 1 0 0 44 1 8 13 422 775Hz 0 85 on 0 5 off x3 1s gap NFPA Temporal Coded 0 0 1 1 0 0 44 1 8 14 1000 2000Hz 1Hz Singapore 1 0 1 1 0 0 23 3 35 15 300Hz Continuous 0 1 1 1 0 0 44 24 35 16 440Hz Continuous 1 1 1 1 0 0 44 24 35 17 470Hz Continuous 0 0 0 0 1 0 44 24 35 18 ...

Страница 8: ...3Hz Sweeping 1 0 0 0 1 1 44 24 12 51 600 1250Hz 0 125Hz Sweeping 0 1 0 0 1 1 44 24 12 52 660 1200Hz 1Hz Sweeping 1 1 0 0 1 1 64 24 12 53 800 1000Hz 1Hz Sweeping 0 0 1 0 1 1 56 24 12 54 800 1000Hz 7Hz Sweeping 1 0 1 0 1 1 57 24 12 55 800 1000Hz 50Hz Sweeping 0 1 1 0 1 1 54 24 12 56 2400 2900Hz 7Hz Sweeping 1 1 1 0 1 1 57 24 12 57 2400 2900Hz 1Hz Sweeping 0 0 0 1 1 1 47 24 12 58 2400 2900Hz 50Hz Swe...

Страница 9: ...st setting see volume control section The sounder section produces a sound pressure level above 75dB A at 10 feet For fire alarm use the temporal pattern tone No 12 as per the tone table provided in these instructions must be selected This tone produces a minimum sound pressure level of CAN ULC S525 100 4dB A at 10 feet anechoic room UL464 92 2dB A at 10 feet reverberation room 3 Surge Current Rat...

Страница 10: ...2 and Stage 3 to ve AC D2XC2X05 D2XC2X10 UNITS Power Live Neutral Stage 1 Apply power to Sounder L N Stage 2 Apply power to Sounder L N Connect Stage 2 to Common Stage 3 Apply power to Sounder L N Connect Stage 3 to Common Stage 4 Apply power to Sounder L N Connect Stage 2 and Stage 3 to Common OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED REQUIRED MINIMUM VALUES R1 24VDC 1KΩ MIN 2W MIN OR 3...

Страница 11: ...therlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 3G Ex ec IIC T6 T4 T3 T2 T1 Gc II 3D Ex tc IIIC Ex tc IIIC T55 75 80 85 90 95 105 110 C Dc IP66 Ingress Dust Protection to EN60079 0 EN60079 31 Standards applied EN IEC 60079 0 2018 EN IEC 60079 7 2015 A1 2018 EN 60079 31 2014 Directive 2014 3...

Страница 12: ...te and Place of Issue London 22 08 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technical and regulatory requirements of the above listed directives regulations and standards This Declaration is issued under the sole responsibility of the ma...

Страница 13: ... Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 3G Ex ec IIC T6 T4 T3 T2 T1 Gc II 3D Ex tc IIIC Ex tc IIIC T55 75 80 85 90 95 105 110 C Dc IP66 Ingress Dust Protection to EN60079 0 EN60079 31 Standards applied EN IEC 60079 0 2018 EN IEC 60079 7 2015 A1 2018 EN 60079 31 2014 Directive 2014 30 EU Electromagnetic Com...

Страница 14: ... Place of Issue London 22 08 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technical and regulatory requirements of the above listed directives regulations and standards This Declaration is issued under the sole responsibility of the manufa...

Отзывы: