background image

 

 

 

 

 

 

 

E2S

 

Telephone:

 

+44

 

(0)20

 

8743

 

8880

 

Fax:

 

+44

 

(0)20

 

8740

 

4200

 

Email:

 

[email protected]

 

www.e2s.com

 

DC

067_Issue_H

 

(D1x).docx

 ‐ 

Page

 

1

 

of

 

2

 ‐ 

QAF_252_Issue_5

 

EU

 

Declaration

 

of

 

Conformity

 

Manufacturer:

   

 

European

 

Safety

 

Systems

 

Ltd.

 

 

 

 

Impress

 

House,

 

Mansell

 

Road,

 

Acton

 

 

 

 

London,

 

W3

 

7QH

 

 

 

 

United

 

Kingdom

 

 

Authorised

 

Representative:

 

E2S

 

Warnsignaltechnik

 

UG

 

 

 

 

Charlottenstrasse

 

45

51

 

 

 

 

72764

 

Reutlingen

 

 

 

 

Germany

 

 

Equipment

 

Type:

  

 

D1xS1,

 

D1xS2

 

 

 

 

D1xL1,

 

D1xL2

 

 

 

 

D1xC1X05,

 

D1xC1X10,

 

D1xC2X05,

 

D1xC2X10

 

 

 

 

D1xB2XH1,

 

D1xB2XH2

 

 

Directive

 

2014/34/EU:

 

Equipment

 

and

 

Protective

 

Systems

 

for

 

use

 

in

 

Potentially

 

Explosive

 

Atmospheres

 

(ATEX)

 ‐ 

D1xS1,

 

D1xS2,

 

D1xL1,

 

D1xL2,

 

D1xC1X05,

 

D1xC1X10,

 

D1xC2X05

 

and

 

D1xC2X10

 

only

 

Notified

 

Body

 

for

 

EU

 

type

 

Examination

 

(Module

 

B):

 

UL

 

International

 

Demko

 

A/S

 

Borupvang

 

5A

 

2750

 

Ballerup

 

Denmark

 

EU

type

 

Examination

 

Certificate

 

(Module

 

B):

 

DEMKO

 

19

 

ATEX

 

2141X

 

Notified

 

Body

 

for

 

Quality

 

Assurance

 

Notification

 

/

 

Conformity

 

to

 

EU

type

 

based

 

on

 

quality

 

assurance

 

of

 

the

 

production

 

process

 

(Module

 

D):

 

Sira

 

Certification

 

Service

 

Notified

 

Body

 

No.:

 

2813

 

Unit

 

6,

 

Hawarden

 

Industrial

 

Park,

 

Hawarden,

 

Deeside,

 

CH5

 

3US,

 

UK

 

Quality

 

Assurance

 

Notification

 

(Module

 

D):

 

SIRA

 

05

 

ATEX

 

M342

 

Provisions

 

fulfilled

 

by

 

the

 

equipment:

 

II

 

2G

 

Ex

 

db

 

IIC

 

T6…T3

 

GB

 

II

 

2D

 

Ex

 

tb

 

IIIC

 

T82

  ̊

C…145

  ̊

C

 

Db

 

Standards

 

applied:

 

EN

 

60079

0:2018

 

EN

 

60079

1:2014

 

EN60079

31:2014

 

Directive

 

2014/30/EU:

 

Electromagnetic

 

Compatibility

 

Directive

 

(EMC)

  

Standards

 

applied:

 

EN

 

61000

6

1:2007

 

EN

 

61000

6

2:2005

 

EN

 

61000

6

3:2007

 

/

 

A1:2011

 

/

 

AC:

 

2012

 

EN

 

61000

6

4:2007

 

/

 

A1:

 

2011

 

Directive

 

2014/35/EU:

 

Low

 

Voltage

 

Directive

 

(LVD)

 

Standards

 

applied:

 

EN

 

60947

1:2007

 

+

 

A2:2014

 

Directive

 

2011/65/EU:

 

Restriction

 

of

 

the

 

use

 

of

 

certain

 

hazardous

 

substances

 

in

 

electrical

 

and

 

electronic

 

equipment

 

(RoHS)

 

The

 

product

 

and

 

all

 

the

 

components

 

contained

 

within

 

it

 

are

 

in

 

accordance

 

with

 

the

 

restriction

 

of

 

the

 

use

 

of

 

hazardous

 

substances

 

in

 

electrical

 

and

 

electronic

 

equipment,

 

including

 

amendment

 

by

 

Directive

 

2015/863/EU.

 

Regulation

 

(EC)

 

1907/2006:

 

Registration,

 

Evaluation,

 

Authorisation

 

and

 

Restriction

 

of

 

Chemicals

 

(REACH)

 

The

 

product

 

and

 

all

 

the

 

components

 

contained

 

within

 

it

 

are

 

free

 

from

 

substances

 

of

 

very

 

high

 

concern.

 

Other

 

Standards

 

and

 

Regulations

 

EN

 

60529:1992+A2:2013

 ‐ 

Degrees

 

of

 

protection

 

provided

 

by

 

enclosures

 

(IP

 

code)

 

 

enclosure

 

rated

 

IP66

 

 

 

Содержание D1xS1RDC024-S

Страница 1: ...G IN CONDUIT RUNS WITHIN 18 INCHES FROM ENCLOSURE EQUIPMENT MUST NOT BE INSTALLED WITH THE HORN FACING UPWARDS OF HORIZONTAL DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGI...

Страница 2: ...e for electrical ratings of each unit model Certificate No DEMKO 19ATEX2141X IECEx ULD 19 0008X UKEx UL UL21UKEX2132X Epsilon x Equipment Group and Category II 2G II 2D CE Marking and Notified Body No...

Страница 3: ...on where it may be subjected to external conditions that might cause a build up of electrostatic charges on non conducting surfaces Only the explosionproof cover is to be used for access to the enclos...

Страница 4: ...s on the line and the length of the cable runs The cable size selected must have the necessary capacity to provide the input current to all the sounders connected to the line DC 0 2 2 5mm2 AWG24 AWG12...

Страница 5: ...3 Tone Selection The D1x Alarm Horn Sounders have 64 different tones that can be selected independently for the first and second stage alarms The tones are selected by operation of the tone setting DI...

Страница 6: ...0 5W or a minimum resistance value of 500 ohms and a minimum wattage of 2W The resistor must be connected directly across the ve and ve terminals as shown in the following drawing The resistor leads s...

Страница 7: ...ing DC Only End of Line Devices may be fitted between the ve ve terminals of the PCBA Please ensure that the device legs meet the wire size range stated for the connection terminals and are fitted cor...

Страница 8: ...perates as part of a SIL 2 system The sounder will after commissioning remain powered in Standby mode reverse polarity until the sounder is required to operate When the signaling device is required to...

Страница 9: ...rity mode When Commissioning system the power must not be disrupted to the SIL 2 Unit within the unit s initialization cycle which is 5 seconds Once past this period the SIL 2 system is fully operatio...

Страница 10: ...under check on pattern generation and signal output checks Important Only tones use tones that are stated as SIL 2 approved for the SIL 2 application Ensure that the unit is set to one of these tones...

Страница 11: ...rom the circuit Note a cable short circuit will not be detectable in this configuration For one unit only Sounder power supply terminal block Current drawn mA Active Mode 190mA Standby Mode 25mA SIL2...

Страница 12: ...multiple SIL 2 alarm horn sounders are to be cabled in series the monitoring connections differ from that of a single alarm horn sounder For more information see manual D197 00 651 IS available from t...

Страница 13: ...ion B pins 2 3 linked Places power supply terminal Fault resistor RLY 1 2 in circuit As used in 2 Wire Configuration Figure 14 J2 Header pin positions Fault Resistor FR 16 4 SIL 2 Hard Reset Function...

Страница 14: ...o input D1xS1FDC024 S D1xS1RDC024 S Failure to Sound Integrity in respect of failure to release SIL 2 Total Failure rate 0 447 pmh hazardous failure rate revealed 0 443 pmh hazardous failure rate unre...

Страница 15: ...g The values of resistors available are shown in table 7 below Code Resistor Value Default resistor coding as follows D1xS1FDC024AB1S1R AFZ Example of a custom requirement resistor coding D1xS1FDC024A...

Страница 16: ...0 1 0 0 1 0 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 1 0 1 1 1 0 1 0 1 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 1 0 1 1 0 0 1 1 1 1 0 0 1 0 0 0 1...

Страница 17: ...OUT Common ve IN Common ve OUT Stage 2 ve Stage 1 ve IN Stage 1 ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 3 ve EOL EOL S2 EOL S2 S3 Stage 1 ve IN Stage 1 ve OUT Stage 1 ve IN Stage 1 ve OUT...

Страница 18: ...S NTS SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED Stage 2 ve Common ve IN Common ve OUT Stage 1 ve OUT Stage 3 ve Stage 1 ve IN H2 H1 OF 2 2 EOL S2 S3 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUP...

Страница 19: ...warden Industrial Park Hawarden Deeside CH5 3US UK Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 GB II 2D Ex tb IIIC T82 C 145 C...

Страница 20: ...e and Place of Issue London 10 02 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Страница 21: ...CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 GB II 2D Ex tb IIIC T82 C 145 C Db Standards applied EN 60079 0 2018 EN...

Страница 22: ...te and Place of Issue London 24 02 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on th...

Отзывы: