European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)208 743 8880 

                                                                                                                                                             www.e2s.com             Fax: +44 (0)208 740 4200 
Document No. D190-00-301-IS-SC     Issue:  8                        24-04-19               Sheet 2 of 8 

 

3.3 Fire Alarm Rating 

 
The  following  models  are  approved  for  use  as  audible  signal 
appliances  for  fire  alarm  use 

–  public  mode  and  produce  a 

sound pressure level above 75dB(A) at 10 feet: 
 
D1xC1X05-DC024 / D1xC1X10-DC024 
D1xC2X05-DC024 / D1xC2X10-DC024 
 
For  public  mode  fire  alarm  use  the  temporal  pattern  tone  No. 
12 as per the tone table provided in these instructions must be 
selected. Only units with clear lens may be used. 
 

3.4 Ambient Temperature Range: 

 
For D1xC1X05-DC024 / D1xC1X05-AC115 
-40ºC to +70ºC (D1xC1X05-DC024 / D1xC1X05-AC115 only) 
 
For D1xC1X05AC230 / D1xC1X10 / D1xC2X05 / D1xC2X10 
-40ºC to +55ºC  
 

3.5 Ingress Protection Ratings 

 
The product is rated for ingress protection as follows: 
 

IP rating per EN60529: 

 

IP66 

 

Type rating per UL50E / NEMA250: 

4 / 4X / 3R / 13  

 
D1xC1 has been tested and found suitable for use in 
atmospheres containing the following chemicals in accordance 
with UL1203: 
 
Acetone 
Ammonium Hydroxide 
Diethyl Ether 
Ethyl Acetate 
Ehylene Dichloride 
Furfural 
n-Hexane 
Methyl Ethyl Ketone 
Methanol 
2-Nitropropane 
Toluene 

 
3.6 

ATEX / IECEx certification 

 

The  D1xC1  Combined  Alarm  Horns  comply  with  the  following 
standards for hazardous locations:  
 
EN60079-0:2018/ IEC60079-0: ed. 7.0 (2017) 
EN60079-1:2014 / IEC60079-1: ed. 7.0 (2014) 
 
The  D1xC1X05DC024  Combined  Alarm  Horns  are  rated  as 
follows: 

 
Ex db IIC T4 Gb Ta -40°C to +75°C 
Ex db IIC T5 Gb Ta -40°C to +60°C 
Ex db IIC T6 Gb Ta -40°C to +45°C 
 

The  D1xC1X05AC115  Combined  Alarm  Horns  are  rated  as 
follows: 

 
Ex db IIC T4 Gb Ta -40°C to +75°C 
Ex db IIC T5 Gb Ta -40°C to +55°C 
Ex db IIC T6 Gb Ta -40°C to +40°C 
 

The  D1xC1X05AC230  Combined  Alarm  Horns  are  rated  as 
follows: 

 
Ex db IIC T4 Gb Ta -40°C to +75°C 
Ex db IIC T5 Gb Ta -40°C to +45°C 

 
Model No.:  

D1xC1 

 

 

 

 

Input Voltage:      DC Units    24V 

              AC Units    115V or 230V 

 
 
 

Certificate No.

     DEMKO 19 ATEX 2141X 

 

 

IECEx ULD 19.0008X 

 

 

 

       

 

 

 

 

 
The units can be installed in locations with the following 
conditions: 

Area Classification Gas: 

Zone 1 

Explosive  gas  air  mixture  likely  to  occur  in 
normal operation. 

Zone 2 

Explosive gas air mixture not likely to occur 
in  normal  operation,  and  if  it  does,  it  will 
only exist for a short time. 

 

Gas Groupings: 

Group IIA 

Propane 

Group IIB 

Ethylene 

Group IIC 

Hydrogen and Acetylene 

 

Temperature Classification: 

T1 

450ºC  

T2 

300ºC 

T3 

200ºC 

T4 

135ºC 

T5 

100ºC  

T6 

85ºC   

 

Equipment Category:

 

2G 

 

Equipment Protection Level:

  

Gb, Gc 

 

Ambient Temperature Range:

      -40

°

C to +75

°

C    

 

Installation must be carried out in compliance with the latest 
issue of the following standards: 
 
EN60079-14 / IEC60079-14: Explosive atmospheres - 
Electrical installations design, selection and erection 
EN60079-10-1 / IEC60079-10-1: Explosive atmospheres - 
Classification of areas. Explosive gas atmospheres 

 
 
 
 
 
 
 
 
 
 
 
 
 

0518 

II  2G 

Epsilon x 
Equipment Group and 
Category: 

CE Marking 
Notified Body No. 

Содержание D1xC1 Series

Страница 1: ...S DE 18 POUCES ÉQUIPEMENT NE DOIT PAS ÊTRE INSTALLÉ AVEC LE KLAXON TOURNÉE VERS LE HAUT DE HORIZONTAL NE PAS OUVRIR UN PRESENCE D ATMOSPHERE EXPLOSIVE NE PAS OUVRIR ENERGIE DANGER POTENTIEL CHARGE ÉLECTROSTATIQUE NETTOYER UNIQUEMENT AVEC UN CHIFFON HUMIDE 3 Ratings and Markings The D1xC1 and D1xC2 combined alarm horns and strobes comply with the following standards for hazardous locations UL 1203 ...

Страница 2: ...th the following standards for hazardous locations EN60079 0 2018 IEC60079 0 ed 7 0 2017 EN60079 1 2014 IEC60079 1 ed 7 0 2014 The D1xC1X05DC024 Combined Alarm Horns are rated as follows Ex db IIC T4 Gb Ta 40 C to 75 C Ex db IIC T5 Gb Ta 40 C to 60 C Ex db IIC T6 Gb Ta 40 C to 45 C The D1xC1X05AC115 Combined Alarm Horns are rated as follows Ex db IIC T4 Gb Ta 40 C to 75 C Ex db IIC T5 Gb Ta 40 C t...

Страница 3: ...40Vac 60Hz D1xC2X05 DC024 24Vdc 924 mA 323 mA 1247 mA 20 28Vdc 1477 mA 20Vdc D1xC2X05 AC115 115Vac 60Hz 268 mA 130 mA 398 mA 110 120Vac 50 60Hz 446 mA 110Vac 60Hz D1xC2X05 AC230 230Vac 50Hz 159 mA 79 mA 238 mA 220 240Vac 50 60Hz 255 mA 220Vac 60Hz D1xC2X10 DC024 24Vdc 924 mA 673 mA 1597 mA 20 28Vdc 1984 mA 20Vdc D1xC2X10 AC115 115Vac 60Hz 268 mA 247 mA 515 mA 110 120Vac 50 60Hz 604 mA 120Vac 60Hz ...

Страница 4: ...ree 7mm fixing holes The enclosure provides IP66 protection and is suitable for installation in exterior locations providing it is positioned so that water cannot collect in the horn and the cable entry is sealed 4 4 Installation procedure a Secure the D1x alarm horn to a flat surface via the three 7mm fixing holes in the mounting bracket b Remove the explosionproof cover of the alarm horn by unsc...

Страница 5: ...es on first and second stages and which tones are available for the third and fourth stages dependent on the Stage 1 DIP switch setting 8 Stage Switching Polarity DC Units Only The D1xC2 and D1xC1 DC alarm horns have the facility to use either ve or ve switching to change the tone to the second third and fourth stages For ve switching connect the two headers on the pcb to the left hand marked ve a...

Страница 6: ...witch 1 alters stage 4 tone Fig 8 DC Terminals 11 Earthing The unit has both a primary internal and secondary external earth fixing point Internal earth connections should be made to the internal Earth terminal see Fig 3 and 4 It should be fitted to the internal earth point using a ring crimp terminal to secure the earth conductor In addition external earth connections can be made to the M5 earth ...

Страница 7: ... 9 34 1 10 1000Hz 1s on 1s off x7 7s on 1s off IMO Code 1a 1 0 0 1 0 0 10 34 1 11 420Hz 0 5s on 0 5s off x3 1s gap ISO 8201 Temporal Pattern 0 1 0 1 0 0 11 1 8 12 1000Hz 0 5s on 0 5s off x3 1s gap ISO 8201 Temporal Pattern 1 1 0 1 0 0 12 1 8 13 422 775Hz 0 85 on 0 5 off x3 1s gap NFPA Temporal Coded 0 0 1 1 0 0 13 1 8 14 1000 2000Hz 1Hz Singapore 1 0 1 1 0 0 14 3 35 15 300Hz Continuous 0 1 1 1 0 0...

Страница 8: ... 0 1 48 24 12 49 560 1055Hz 0 18Hz Sweeping 0 0 0 0 1 1 49 24 12 50 560 1055Hz 3 3Hz Sweeping 1 0 0 0 1 1 50 24 12 51 600 1250Hz 0 125Hz Sweeping 0 1 0 0 1 1 51 24 12 52 660 1200Hz 1Hz Sweeping 1 1 0 0 1 1 52 24 12 53 800 1000Hz 1Hz Sweeping 0 0 1 0 1 1 53 24 12 54 800 1000Hz 7Hz Sweeping 1 0 1 0 1 1 54 24 12 55 800 1000Hz 50Hz Sweeping 0 1 1 0 1 1 55 24 12 56 2400 2900Hz 7Hz Sweeping 1 1 1 0 1 1 ...

Отзывы: