European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)208 743 8880 

                                                                                                                                                            www.e-2-s.com              Fax: +44 (0)208 740 4200 
Document No.D210-00-031-IS 

Issue 1        18-08-16                         Sheet 1 of 7

 

                                                           

INSTRUCTION MANUAL (ATEX / IECEx) 

BExH120D and BExH120D-R Hootronic Flameproof Sounders 

For use in Flammable Gas and Dust Atmospheres

 

 

 

 

 

 

 

 

1) Warnings 

 DO NOT OPEN WHEN AN EXPLOSIVE 

ATMOSPHERE IS PRESENT 

 DO NOT OPEN WHEN ENERGIZED 

 POTENTIAL ELECTROSTATIC CHARGING 

HAZARD 

 COVER BOLTS CLASS A4-80 

 USE HEAT RESISTING CABLES AND CABLE 

GLANDS (RATED 110°C) AT AMB. 
TEMPERATURES OVER 40°C 

 

2)  Rating & Marking Information 

 

All units have a rating label, which carries the following 
important information:- 

 

Model No.:

  

BExH120D or BExH120D-R 

 

Input Voltage:

     DC Units    24V 

              AC Units    115V or 230V 

 

BExH120D or BExH120D-R Codes:  

Ex d IIC T4 Gb Ta. -50°C to +55°C  
Ex d IIB T4 Gb Ta. -50°C to +70°C 
Ex tb IIIC T100°C Db Ta. -50°C to +55°C 
Ex tb IIIC T115°C Db Ta. -50°C to +70°C  

 

Certificate No.

    KEMA 99ATEX6312X 

  IECEx 

KEM 

10.0003X 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

The units can be installed in locations with the following 
conditions: 

 

Area Classification Gas: 

Zone 1 

Explosive gas air mixture likely to occur in 
normal operation. 

Zone 2 

Explosive gas atmosphere not likely to 
occur in normal operation but may be 
present for short periods. 

 

Gas Groupings: 

Group IIA 

Propane 

Group IIB 

Ethylene 

Group IIC 

Hydrogen and Acetylene (up to 55°C 
ambient)       

 

Temperature Classification: 

T1 450ºC 

 

T2 300ºC 
T3 200ºC 
T4 135ºC 

 

Area Classification Dust: 

Zone 21 

Explosive dust air mixture likely to occur in 
normal operation. 

Zone 22 

Explosive dust air mixture not likely to 
occur in normal operation, and if it does, it 
will only exist for a short time. 

 

Dust Groupings: 

Group IIIA 

Combustible Dusts 

Group IIIB 

Non-Conductive Dust 

Group IIIC 

Conductive Dust 

 

Maximum Surface Temperature for Dust Applications: 

100ºC at +55 ºC ambient 

115 ºC at +70 ºC ambient 

 

IP Rating:  

IP66/67 and IP6X to EN/IEC60079-0, 
EN/IEC60079-31 

 

Equipment Category:

 

2G / 2D 

 

Equipment Protection Level:

 

Gb / Db 

 

Ambient Temperature Range:

 

-50°C to +55°C Gas Groups IIA, IIB and IIC 

-50°C to +70°C Gas Groups IIA and IIB 

-50°C to +70°C Dust Groups IIIA, IIIB and IIIC 

0518 

II  2G 
II  2D 

Epsilon x 
Equipment Group and 
Category: 

CE Marking 
Notified Body No. 

BExH120D 

BExH120D-R 

Содержание BExH120D

Страница 1: ...ate No KEMA 99ATEX6312X IECEx KEM 10 0003X The units can be installed in locations with the following conditions Area Classification Gas Zone 1 Explosive gas air mixture likely to occur in normal oper...

Страница 2: ...The location of the hootronic sounder should be made with due regard to the area over which the warning signal must be visible They should only be fixed to services that can carry the weight of the un...

Страница 3: ...topping plugs cannot be fitted onto adapters only directly onto the M20 entries Any other adapters used must be suitably rated and ATEX IECEx certified adapters 10 Earthing Both AC and DC hootronic so...

Страница 4: ...nd N supply terminals see fig 4 12 2 2 AC Units Second and Third Stage Tone Selection To select the second and third stage tones on the BExH120 AC hootronic sounder Stage two S2 Operation Power L and...

Страница 5: ...Header Pins alters stage 2 tone Stage three S3 Operation Power ve and ve link a ve supply line to the S3 terminal Header pins alters stage 3 tone 2 3 S top 1 2 3 S2 S3 Stop ve ve Fig 7 DC Terminals 1...

Страница 6: ...The sounders can then be switched to sound second and third stage alarm sounds The sounds are selected by pin headers on the pcb for both DC and AC units The sound table below shows the pin header pos...

Страница 7: ...y suitably qualified personnel in accordance with the current relevant standards EN60079 19 IEC60079 19 Explosive atmospheres Equipment repair overhaul and reclamation EN 60079 17 IEC60079 17 Explosiv...

Отзывы: