E2S BExBG10D-P Скачать руководство пользователя страница 3

 

 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

www.e2s.com

 

Tel: +44 (0)208 743 8880

Document No. D210-00-211-IS

 

Issue 5

 

12-09-2022

Sheet 3 of 6

 

5.  Special Conditions for Safe Use 

 

Repair of the flamepath / flameproof joints is not permitted. 

 

The  enclosure  is  non-conducting  and  may  generate  an 
ignition-capable  level  of  electrostatic  charges  under  certain 
extreme conditions (such as high-pressure steam). The user 
should ensure that the equipment is not installed in a location 
where  it  may  be  subjected  to  external  conditions  that  might 
cause  a  build-up  of  electrostatic  charges  on  non-conducting 
surfaces. 

 

Additionally,  cleaning  of  the  equipment  should  be  done  only 
with a damp cloth. 

 

6.  Product Mounting and Access 

 

The location of the beacon should be made with due regard to 
the area over which the warning signal must be visible. They 
should only be fixed to services that can carry the weight of the 
unit. 

 

The BEx beacon should be secured to any flat surface using 
at least two of the three 7mm fixing holes on the stainless steel 
U shaped mounting bracket. See Figure 1. The required angle 
can be achieved by loosening the two large bracket screws in 
the side of the unit, which allow adjustment of the beacon in 
steps of 18°. On completion of the installation then two large 
bracket adjustment screws on the side of the unit must be fully 
tightened to ensure that the unit cannot move in service. 
 
The equipment should not be mounted with the dome facing 
downwards of horizontal. 

 

145,0

30,0

30,0

126,8

229,2

137,00

 

 

Fig. 1 Fixing Location for Beacon 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

7.  Access to the Flameproof Enclosure 

 

 

 

To  access  the  Ex  d  chamber,  remove  the  four  M6  hexagon 
socket head screws and withdraw the flameproof cover taking 
extreme  care  not  to  damage  the  flameproof  joints  in  the 
process. M6 cover screws are Class A4-80 stainless steel and 
only screws of this category can be used for the enclosure. 
 

 

Fig. 2 Accessing the Explosion proof Enclosure. 

 

On completion of the installation, the flameproof joints should 
be inspected to ensure that they are clean and that they have 
not been damaged during installation. 

 

On completion of the installation, the flameproof joints should 
be inspected to ensure that they are clean and that they have 
not been damaged during installation. 

 

Check that the earth bonding wire between the two castings is 
secure  and  the  ‘O’  ring  seal  is  in  place.  When  replacing  the 
flameproof  cover  casting  ensure  that  it  is  square  with  the 
flameproof  chamber  casting  before  inserting.  Carefully  push 
the cover in place allowing time for the air to be expelled. Only 
after  the  cover  is  fully  in  place  should  the  four  M6  Stainless 
Steel  A4-80  cover  bolts  and  their  spring  washer  be  inserted 
and tightened down. If the cover jams while it is being inserted, 
carefully remove it and try again. Never use the cover bolts to 
force the cover into position. 

 
 

 

Warning – High voltage may be present, 
risk of electric shock. DO NOT open when 
energised, disconnect power before 
opening. 

Warning – Hot surfaces. External surfaces 
and internal components may be hot after 
operation, take care when handling the 
equipment. 

(Appropriate cable glands 
to be customer supplied)

Flameproof cover  

M6 Cover 
Screws 

M6 Spring 
Washer 

90º 

Содержание BExBG10D-P

Страница 1: ...BExBG15DPDC048 48Vdc 480mA 54V BExBG15DPAC115 115Vac 360mA 126V BExBG15DPAC230 230Vac 170mA 253V It is important that a suitable power supply is used to run the equipment The power supply selected mu...

Страница 2: ...occur in normal operation and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Group IIC Hydrogen and Acetylene Temperature Classification for Gas Appl...

Страница 3: ...5 0 30 0 30 0 126 8 229 2 137 00 Fig 1 Fixing Location for Beacon 7 Access to the Flameproof Enclosure To access the Ex d chamber remove the four M6 hexagon socket head screws and withdraw the flamepr...

Страница 4: ...nit Fig 3 Internal View of Cover When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming earth wire and the enclosure Internal earthing connection...

Страница 5: ...lue of 3k3 ohms and a minimum wattage of 0 5 watts or a minimum resistance value of 500 ohms and a minimum wattage of 2 watts Fig 7 End of Line Resistor Placement 14 Settings 14 1 Synchronised Operati...

Страница 6: ...l Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN60079 19 IEC60079 19 Explosive...

Страница 7: ...NEAR DIMENSIONAL TOLS ANGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE...

Страница 8: ...OVE DRAWING TO BS8888 2000 GEOMETRIC TOLERANCES TO ISO1101 1983 LINEAR DIMENSIONAL TOLS ANGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT...

Страница 9: ...2813 CSA Group Netherlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment I 2G Ex db IIC T6 T3 Gb II 2G...

Страница 10: ...and Place of Issue London 20 04 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the mar...

Страница 11: ...Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 2G Ex db IIC T6 T3 Gb II 2G Ex db eb IIC T5 T4 Gb II 2D Ex tb IIIC T...

Страница 12: ...nd Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the ma...

Отзывы: