A131 High Level Audible Warning System / Battery backup 

European Safety Systems Ltd.

  

Impress House, Mansell Road, Acton, London W3 7QH    

 

 

[email protected]

     Tel: +44 (0)208 743 8880 

                                                                                                                                                        

www.e2s.com

    Fax: +44 (0)208 740 4200 

Document No. D5423-D5426-IS_Issue_B 12-02-13 
 
 Sheet 

of 

 
Fig 1-2 Battery Installation 
 
 
 
 
There is a set of contacts that change over on a 
system fault, this includes a battery fault or a 
charging fault. 
 
 

9) Wiring of Control Unit to Power and 
horn units 

 
For wiring schematics see figures 3. The control 
unit needs to be wired to a suitable power supply 
cable supplied by the customer. The power 
terminals on the control unit are clearly marked 
and will accept up to 2.5mm

2

 cable. See figure 2.  

 
The cable from the horn to the control unit is 10m 
in length. It should be fed through the cable gland 
in the control unit and then wired into the terminal 
block provided. 
 
To keep horns in-phase ensure that the red horn 
cable is connected to the brown and the blue to 
the blue. See figure 3. 
As all the sounder units are synchronized it does 
not matter which unit is cabled into which board. 
 

 

10) Tone Selection Table 

 
The A131 high level audible warning system has 
45 different tones that can be selected for the first 
stage alarm. The systems can then be switched 
to sound second and third stage alarm tones. The 
tones are selected by operation of a DIP switch in 
the control unit.  
 
The tone table below shows the switch positions 
for the 45 tones and which tones are available for 
the second and third stages.  
 
 
 
 
 
 
 
 
 

 

 
Table 2: Tone selection table 

 
 
 
 
 

 

 
 
 
 
 
 