General

 

 

 

Standards

 

802.11b/g (WLAN), 802.3/802.3u (LAN)

 

Modulation

 

(b) DSSS (DBPSK, DQPSK, CCK) 
(g) OFDM (64QAM, 16QAM, QPSK, BPSK)

 

Certifications

 

FCC / CE

 

Radio Specifications

 

 

 

Operating Frequency

 

2400 to 2497MHz

 

Channels

 

USA/Canada 11; Japan 14; France 4; 
Europe 13

 

Available Transmit Power  
(software selectable)

 

802.11b 100, 150, 200, 250mW 
802.11g  50, 100mW 

 

Receive Sensitivity @ 11Mbps

 

802.11g  -73 +2dBm @ 54Mbps 
802.11b  -84 +2dBm @ 11Mbps

 

Security

 

64/128bit WEP, WPA, WPA2

 

Remote Config (Web Based)

 

By IP Address; thru Wireless or Ethernet

 

Antenna Specifications

 

 

 

Antenna Gain

 

15 dBi

 

Antenna Beamwidth (V & H)

 

35 deg

 

Antenna Front to Back

 

>18dB

 

Polarization

 

Horizontal or Vertical

 

POE Specification

 

 

 

Power Over Ethernet Injector 

 

INPUT: 100 – 240VAC @ 50 – 60Hz OUT-
PUT: 18VDC @ 0.8A

 

Mechanical Specifications

 

 

 

Color

 

White 

 

Dimensions (L x W x H)

 

10.8” x 10.8” x 3”  (273 x 273 x 76mm)

 

System Weight

 

4.4 lb (2 kg) 

 

Ethernet Connector

 

Field Replaceable Waterproof RJ45

 

Mount

 

Pole (up to 2” dia) Mount

 

Environmental Specifications

 

 

 

Operating Temperature

 

-22 to 122 Deg F (-30 to +50 Deg C)

 

Humidity

 

0 to 100% RH

 

Wind Loading (125MPH survivability)

 

100MPH / 28lbs; 125MPH / 43lbs

 

Technical Specifications      

Note: Subject to Change Without Notice

 

Содержание EZ2R15B

Страница 1: ...5 30 45 60 75 90 105 120 135 150 165 180 165 150 90 75 60 45 30 15 h v 1 3 6 10 25 2400 0 MHz Antenna Pattern Achieve up to 15 Mbit sec data thruput Long Distance operation with good line of sight Bes...

Страница 2: ...wy day or if there is ice or snow accumulation at the install site or if the site is wet Make sure there are no people pets etc below when you are working on a roof or ladder Watch out for any power l...

Страница 3: ...the feedthru cable clamp STEP 5 Route a CAT5 cable from the EZ2 into the building Always create a drip loop near the antenna so the cable is not pulling on the antenna and any water running down the c...

Страница 4: ...efault is no user name or pass word for ease of system setup b ENCRYPTION Set an encryption type and key We recom mend WPA2 because it is most secure but if this install is as a client the encryption...

Страница 5: ...some reduced per formance assuming you are shooting a long distance 3miles and the ice or snow buildup is greater than 1 thick on the surface of the an tenna For this reason we suggest mounting under...

Страница 6: ...energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a part...

Страница 7: ...able 802 11b 100 150 200 250mW 802 11g 50 100mW Receive Sensitivity 11Mbps 802 11g 73 2dBm 54Mbps 802 11b 84 2dBm 11Mbps Security 64 128bit WEP WPA WPA2 Remote Config Web Based By IP Address thru Wire...

Страница 8: ...nada customer pays all shipping charges incurred to ship the product to E ZY NET E ZY NET pays shipping charges to return the product to the original pur chaser For all other countries the original pu...

Отзывы: