Advanced Features

 

The  EZ-Base™ 

 

has  many  advanced  features  if  more  functionality  is 

desired.  To access the advanced features, click on  Advanced Web at 
the top of the menu tree. This will activate the advanced menu options.  

Since  documentation  for  these  advanced  modes  is  too  extensive  to 
cover  here  please  retrieve  the  documentation  online  at  http://ez-
bridge.com/support/support.htm 

TECH CORNER

  

Additional Information you may find useful 

1.

 

RAIN, SNOW, ICE 

 

The frequencies being used by the EZ-Base™ 

will  not  be  affected  by  heavy  rain  or  falling  snow.  You  should  not  see 
any performance degradation due to inclement weather. 

2.

LIGHTNING 

 

Lightning  is  the  single  worst  enemy  of  outdoor  elec-

tronics  equipment.  No  electronics  will  survive  a  direct  strike  but  there 
are  close  proximity  strikes  that  can  cause  huge  electrical  fields  to  be 
generated  which  can  damage  electronic  equipment.  We  have  taken 
special  care  in  the  design  of  the  EZ-Base™  unit  to  ensure  proper 
grounding  of  the  electronics  inside  the  enclosure  to  prevent  damage 
from electrical storms. Always use DC grounded antennas. Make sure 
that  the  POE  Power  Supply  is  plugged  into  a  surge  protected  outlet 
such  as  a  surge  protected  power  strip  or  UPS  inside  the  house. 
Shielded CAT5 cable is also recommended between the POE Inserter 
and the EZ-Base™. 

5.

 INTERFERENCE 

– The most common cause of poor performance is 

due to interference from other wireless devices in the area. Interference 
can cause poor throughput and in the worse case, a lockup.  It’s always 
good to do a site survey  using the EZ-Base control panel to see what 
other wireless devices are in the area and then choose a wireless chan-
nel  that  is  at  least  2  channels  away  from  any  strong  offending  signal. 
Keep in mind that even though alls well today somebody could setup a 
new system and create interference with your system at any time. If you 
suspect  interference,  change  channels.  There  is  also  a  Watchdog 
Timer built into the EZ-Base which you can set to ping a remote device. 
If  connection  is  lost  the  unit  will  automatically  reboot.  This  is  useful  if 
you experience frequent lockups. Lowering the Beacon Interval on the 
Wireless  Advanced  Settings  page  can  help  improve  performance  in 
areas of intense interference. 

Содержание EZ-Base

Страница 1: ...r battery backup Integrated battery backup for powerline filtering and 24 7 operation Achieve up to 15 Mbit sec speed 25Mbps for 5GHz version Includes TriBand omni antenna for up to 0 3miles range Add...

Страница 2: ...round or behind walls keeping safely clear of them with the antenna ladders or any tools See appendix for FCC RF exposure guidelines Recommended Tools Phillips Screwdriver 3mm Allen Wrench 14mm Open E...

Страница 3: ...to a wall or to an existing pole up to 2 diameter The EZ Base can also be mounted indoors if desired TECH TIP Microwaves travel in straight lines and they lose strength quickly when going thru buildin...

Страница 4: ...e controller and the battery volt age is 12V the LOAd LED should be on 2 When the POE power supply is plugged in and CAT5 cable con nected to POE IN the POE LED should be on 3 If LOAd LED is off becau...

Страница 5: ...rans parent bridging between several points Communicates on MAC layer To setup WDS you need the units to be on the same wireless channel they must have the same WDS security settings Enter unit A s MA...

Страница 6: ...DS or Point to Point ap plications Because most WiFi clients don t support WPA encryption use WEP if setting up a WiFi AP hotspot 6 SITE SURVEY The site survey is a very useful tool to determine what...

Страница 7: ...360 90 deg Polarization Vertical Vertical Battery Specification Backup Time 15 hours Recharge Time 4 Hours Typical Battery Life 5 Years POE Specification Power Over Ethernet Power Supply INPUT 100 24...

Страница 8: ...nt damage from electrical storms Always use DC grounded antennas Make sure that the POE Power Supply is plugged into a surge protected outlet such as a surge protected power strip or UPS inside the ho...

Страница 9: ...to open the enclosure and disconnect one of the battery wires from the controller The other way is to unplug the POE Power supply from the AC source and waiting 15 hours for the controller to turn of...

Страница 10: ...g video technologies used for remote conferencing like church meetings business meetings etc Appendix Federal Communication Commission Interference Statement This equipment has been tested and found t...

Страница 11: ...not cover the following Parts requiring replacement due to improper installation misuse poor site conditions faulty power etc Lightning damage Physical damage to the external internal parts Products t...

Страница 12: ...For products out of warranty the standard NFF charge is 200 This charge will be at the discretion of E ZY NET The RMA number is valid for 14 days from date of issue The product must be received by th...

Отзывы: