E-TECH ET8 V4 CONTROL PANEL - USER MANUAL

21

* The Primary and Secondary telephone numbers are normally only

used for central station monitoring. These numbers can only be
programmed in Installer Program Mode.

** The Follow Me Telephone Number replaces the Primary AND

Secondary telephone numbers.

MONITORED PREMISES

AUDIBLE MONITORING

TELEPHONE LINE

MOBILE TELEPHONE

FIXED TELEPHONE

AUDIBLE MONITORING

The ET8 can also be programmed to send
audible messages to any telephone or mobile
phone.

When programmed for audible monitoring, the
ET8 calls a pre-programmed number (or
numbers) and sounds a series of beeps over
the phone. These beeps can identify the zone
or zones which caused the alarm and well as
several other alarm types.

FOLLOW ME TELEPHONE NUMBER

The Follow Me Telephone Number is the
telephone number to which the ET8 sends
alarm reports when Audible Monitoring is
enabled.

The Follow Me Telephone Number can be
changed by the user in User program Mode.

If the Follow Me Telephone Number is
programmed, the Primary and Secondary
telephone numbers are ignored, even if
programmed. (When Audible Monitoring is
enabled).

See page 19 for information on programming
the Follow Me Telephone Number.

AUDIBLE MONITORING SEQUENCE

When triggered by an alarm, the ET8 will dial
the programmed telephone number/s and
output the audible message for 45 seconds or
until it is acknowledged.

ACKNOWLEDGING THE ALARM

The person receiving the call can then
acknowledge the alarm by pressing the 

 key

on their telephone. Press the  

 key for at least

2 seconds during pauses in the audible
message.

If the alarm is not acknowledged, the keypad’s
LINE light will flash continuously until the panel
is next Armed.

Содержание ET8

Страница 1: ...USER S MANUAL Versions commencing November 2001 A 12 00 INC GST E TECH ET8 CONTROL PANEL V4 USER S MANUAL REVISION 1 E TECH ET8 ALARM CONTROL PANEL AND DIALLER...

Страница 2: ...110 12 Security Close Safe Hills NSW 2147 Australia Ph 61 23 9988 7766 Fax 61 23 9988 7765 ET8 V4 INSTALLER MANUAL Revision 1 November 2001 Document Part Number 890 265 For product 100 191 ET8 LED Con...

Страница 3: ...Zones 14 Alarm Memory 15 OPERATION by RADIO KEY 16 PROGRAMMING 17 Programming Options Table 17 User Code programming 18 Entry Exit Timer programming 18 Telephone Number programming 19 Monitoring Cent...

Страница 4: ...True Dynamic Battery Test every time the Panel is armed disarmed and every hour Area Partitionable 2 Areas Any Zone can be programmed to any area as well as common areas Comes complete with an AC plu...

Страница 5: ...e it to detect intruders and generate an alarm After arming the panel will ignore detectors during the Exit Delay Time to enable you to depart without triggering an alarm Arming the system may be done...

Страница 6: ...i e a zone is unsealed there may still be movement in the premises or a door or window left open ARM button ARM button MONITOR button MONITOR button EXCLUDE button EXCLUDE button PROGRAM button ENTER...

Страница 7: ...alarm from a radio device Indicates that a Radio Key or other radio device has a low battery Phone line fault or failure to communicate User Program Mode Not ready to Arm Zone alarm Monitor Mode LED...

Страница 8: ...the alarm is activated requiring the correct code to silence the alarm This prevents anyone trying to guess your code by entering random numbers AREA OPERATION Area Partitioning allows the 8 zones to...

Страница 9: ...s should be Sealed If any are Unsealed the siren will sound for 2 seconds as a warning to indicate that those zones have been automatically excluded For maximum security you should return Disarm check...

Страница 10: ...re programmed on OPERATION Your panel can be reset and the alarm silenced by the same key sequence as Disarming the panel If you arrive at your premises and find the strobe light flashing if installed...

Страница 11: ...e the alarm This will also Disarm the panel so remember to enter monitor again if needed By using the optional Radio Keys you can enter Monitor Mode by pressing the OFF button twice within 4 seconds Y...

Страница 12: ...l To Disarm and send a DURESS alarm prefix your User Code with one of the digits 5 6 8 or 9 when Disarming DURESS alarms are only used if your system is monitored by a Central Station DURESS IS NORMAL...

Страница 13: ...ound Sounds the siren Fire Alarm siren sound Sends a Fire Alarm report by dialler Sends a Fire Alarm report by dialler Press Press LED KEYPAD KEYPAD FIRE ALARM LCD KEYPAD 2 If Medical Alarm Report has...

Страница 14: ...ence to turn OFF the zone lights to be Included The zone light of each Excluded zone will turn on The zone light of each Excluded zone will turn on or User Code Zone No Zone No Zone No Zone No ENTER E...

Страница 15: ...e panel is Armed MEMORY MODE EVENTS INDICATED BY KEYPAD LIGHTS LIGHT ALARM EVENT Zone lights 1 8 Zone alarm ARM Panel Armed no lights Panel Disarmed TAMPER Tamper alarm Siren cover panel etc EXCLUDE P...

Страница 16: ...nabled by your installer The strobe light will flash briefly ARMING MONITOR MODE Press the OFF button twice within 4 seconds The keypad will give 9 beeps The outside siren will NOT chirp The strobe li...

Страница 17: ...e of 6 is programmed the time is 60 seconds PROGRAMMING OPTIONS TABLE PROGRAMMING Various system options as listed below can be programmed by the user These options can only be accessed from Program M...

Страница 18: ...CODE NEW CODE NEW CODE ENTER ENTER ENTER ENTER ENTER Press Press Press Press Press To program User Code 1 The Master Code to be 1234 To program User Code 2 as an ARM ONLY code to be 5678 Press Press P...

Страница 19: ...Program Mode The panel must be in Program Mode Program light ON Master Code Option No NEW TELEPHONE NUMBER NEW TELEPHONE NUMBER ENTER ENTER ENTER ENTER Press Press Press Press Press Press To program t...

Страница 20: ...ne or zones which caused the alarm tamper alarms low battery or mains failure reports and it can also by user number identify the users who Arm and Disarm the system Central Station Monitoring is high...

Страница 21: ...E NUMBER The Follow Me Telephone Number is the telephone number to which the ET8 sends alarm reports when Audible Monitoring is enabled The Follow Me Telephone Number can be changed by the user in Use...

Страница 22: ...as a priority give a constant tone as a warning and then hang up When all remote control commands are finished press to force the ET8 to hang up SEQUENCE OF OPERATION 1 Phone the ET8 telephone number...

Страница 23: ...pare the ET8 3 beeps 4 PRESS User Code to authorise the next command 3 beeps 5 PRESS to Arm the panel 3 beeps 6 PRESS to finish and hang up SUMMARY OF TELEPHONE COMMANDS Prepare to receive commands Ar...

Страница 24: ...available QUANTUM PLUS 15m passive infra red detector with selectable pulse count temperature compensation and downward looking creep zones QUANTUM DUAL 15m combination microwave and passive infra red...

Страница 25: ...available the 100 663PET radio Pet Aware model which detects humans but is immune to household pets E TECH RADIO KEY PENDANT Fully waterproof pendant style transmitter can be used as a portable wirel...

Страница 26: ...Exit Delay time Disarm the panel and check all zones Strobe light is flashing There has been an alarm Reset the alarm by Disarming the panel and check the Alarm Memory Siren sounds while the panel is...

Страница 27: ...UT P57E SIREN OUTPUT P74E Report dialler 1 2 3 4 5 6 7 8 2001 E Tech Security Products P26E ENTRY DELAY TIME 1 Seconds Seconds Seconds Minutes P27E ENTRY DELAY TIME 2 P28E EXIT DELAY TIME P29E SIREN R...

Страница 28: ...D RADIO KEY PANIC PANIC PANIC PANIC ARM ARM MONITOR MONITOR EXCLUDE EXCLUDE MEMORY MEMORY MEMORY ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER To Disa...

Отзывы: