TECHNICAL CHARACTERISTICS
Electrical data of model 36
STAGE
1
STAGE
2
TOTAL
POWER
TERMINALS
Tri phase 36 kW
(*)
Terminals 3 and 4 shunted
Terminal 2 L1 (
A
)
26 26 52
Terminals 5 and 6 shunted
Terminal 3 L2 (
A
)
26 26 52
Relay K5 activated
Terminal 5 L3 (
A
)
26 26 52
Terminal 1
N (
A
)
0 0 0
Power
(
kW
)
18 18 36
1
N
2
L1
3
L2
4
5
L3
6
Tri phase 34 kW
(***)
Terminals 3 and 4 shunted
Terminal 2 L1 (
A
)
26 26 52
Relay K5 activated
Terminal 3 L2 (
A
)
26 26 52
Terminal 5 L3 (
A
)
26 13 39
Terminal 1
N (
A
) 0
13
13
Power
(
kW
)
18 15 33
1
N
2
L1
3
L2
4
5
L3
6
Tri phase 32 kW
(***)
Relay K5 activated
Terminal 2 L1 (
A
)
26 26 52
Terminal 3 L2 (
A
)
26 13 43
Terminal 5 L3 (
A
)
26 13 43
Terminal 1
N (
A
) 0
13
13
Power
(
kW
)
18 14 30
1
N
2
L1
3
L2
4
5
L3
6
Tri phase 30 kW
Terminals 3 and 4 shunted
Terminal 2 L1 (
A
)
26 13 43
Terminals 5 and 6 shunted
Terminal 3 L2 (
A
)
26 13 43
Relay K5 disactivated (**)
Terminal 5 L3 (
A
)
26 13 43
Terminal 1
N (
A
)
0 0 0
Power
(
kW
)
18 9 27
1
N
2
L1
3
L2
4
5
L3
6
This values are based on standard supply voltage in Europe, that is 1 x 230V for single phase and 3 x 400V + N for tri phase.
(*) Factory configuration / (**) Remove the shunt 23 and 24 in order to deactivate the relay / (***) Current not balanced.
Содержание 9
Страница 27: ...EN 27 ENGLISH FRANCAIS NEDERLANDS ESPA OL ITALIANO DEUTSCH 664Y3400 REMOVAL THE HEATING ELEMENTS 2 1 3...
Страница 28: ...EN 28 ENGLISH FRANCAIS NEDERLANDS ESPA OL ITALIANO DEUTSCH 664Y3400...
Страница 29: ...1 664Y3400...
Страница 31: ...3 664Y3400 09 15 22 28 36...
Страница 33: ...5 664Y3400 09 15 22 28 36...
Страница 35: ...7 664Y3400 09 15 22 28 36 _ _ _ _ _ _ _ _ _ _ 24614143 24614144 24614145...