![E.T. Systems E PAD Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/e-t-systems/e-pad/e-pad_user-manual_519277006.webp)
6
Ver.201105.007
ADVANCED PROGRAMMING OPTIONS AND QUICK REFERENCE TABLE.
Need
Action
Factory
Default
Response
Buzzer
Enter programming mode
Master code + Master code
1234
Chime tone up
M
as
te
r
an
d
u
se
r
co
d
e
s
Change master code
*
00 + new master code (4-8 digits) Note the number of digits the
master is set to will be the number of digits all user codes, lock, aux and
bypass.
No chime tone
Set user codes 01 ~ 19 (Lock relay
output only)
*
01~ 19 + new unique user code (Same length as master code)
User 01 =
3333
Chime tone up
Set user codes 20 ~ 39 and 41 ~ 99
(Lock relay output only)
*
6 + 2 digit user new unique user code (Same length as
master code)
Chime tone up
Set user code 40 (Aux relay output
only)
*
40 + new unique aux user code (Same length as master code)
9999
Chime tone up
Keypad lockout on multiple incorrect
code attempts.
*
51 to change status on or off.
De-
activated
Chime tone up
Delete a user code or all user codes. (If
deleting all user 01 defaults to 3333)
*
50 + 00 for all, 01 for user 1, 02 for user 2………………….99 for user 99.
Chime tone up
R
e
la
ys
Select Lock relay type or pulse length.
*
20 + 00 = latch mode or 01 for 1 sec, 02 for 2 sec………99 for 99 sec
1 sec.
Chime tone up
Select Aux relay type or pulse length
*
58 + 000 = latch mode or 001 for 1 sec, 002 for 2 sec………..999 for 999
sec.
Latch
Chime tone up
B
yp
as
s
m
o
d
e
Enable bypass mode.
*
52 + 1
Disabled
Chime tone up
Disable bypass mode.
*
52 + 0
Default
Chime tone up
Setup bypass code
*
54 + new unique bypass code
None
Chime tone up
A
la
rm
m
o
d
es
Disable alarm output mode
*
55 + 0
Disabled
Chime tone up
Select alarm output to activate on
door forced open condition
*
55 + 1 (Door open time limited to equal Lock relay on time)
Not
selected
Chime tone up
Select alarm output to activate on
tamper switch
*
55 + 2
Not
selected
Chime tone up
Select alarm output to activate on
both door forced and tamper switch
*
55 + 3
Not
selected
Chime tone up
Select Alarm output active time
*
56 + 001 for 1 sec, 002 for 2 sec………..999 for 999 sec.
Chime tone up
A
u
xi
lia
ry
m
o
d
es
Disable Aux output
*
57 + 0
Enabled
Chime tone up
Allocate door monitor to work with
Aux output
*
57 + 1
Not
Allocated
Chime tone up
Activate Aux output when multiple
incorrect codes have been entered
*
57 + 2 (Not operational if Aux relay has been set to latch)
Not
Selected
Chime tone up
Activate Aux output when
*
key is
pressed (Doorbell function)
*
57 + 3
Not
Selected
Chime tone up
Activate Aux output when tamper is
activated
*
57 + 4
Not
Selected
Chime tone up
Activate Aux output when door is
forced open
*
57 + 5
Not
Selected
Chime tone up
Activate Aux output together with lock
output
*
57 + 6
Not
Selected
Chime tone up
Aux output only activates when Aux
code is entered
*
57 + 7
Default
Chime tone up
Fa
ct
o
ry
d
e
fa
u
lt
Factory default
Power down
Place jumper across the system restore pins
Power up
Continuous chime
On continuous chime remove jumper and replace it in normal operation
position.
Содержание E PAD