E-matic PMFMC Скачать руководство пользователя страница 4

EMatic_PMFMC_Instructions_Rev01

 

 

The sensitivity is poor: 

o

 

Please check if there is any metallic obstructions in front of the sensor   

o

 

Check that the sensor is mounted with in the recommended mounting height 

o

 

Please check if the moving orientation is correct 

 

 

The sensor cannot turn off the load automatically: 

o

 

Please check if there is a lot of metal in the area i.e. metal containers, walls etc. 

o

 

Please check the TIME and SENS adjustments 

o

 

Please  check  if  the  connections  and  that  a  permanent  Live  is  not  connected  directly  to  the 

load 

 

Specification 

Power Source:   

230v AC 50/60Hz 

Power Consumption:   

approx. 0.9W 

Frequency: 

5.8GHz - 0.2mW 

Ambient Light:   

<3 to 2000LUX (adjustable)                   

Detection Range:   

360° 

Detection Distance:   

1 - 8m Radius 

Installation Height:   

1.5 - 3.5m 

Detection Moving Speed:   

0.6-1.5m/s 

Time Delay:   

Min.10sec ±3sec                                     

 

                       

Max.12min ±1min 

Working Humidity:   

<93%RH 

Working Temperature:   

-20~+40C 

Dimensions: 

75mmx76mm 

Hole Cut Out Size: 

62-65mm 

Weight: 

120g (net) 

IP Rating: 

IP20                                   

 

 

Rated Load:   

 

 

 

Fluorescent: 

Max.1200W                                               

Energy Saving: 

Max. 300W     

LED: 

Max. 300w or maximum 6 number of LED drivers         

 

Environment: 

Please DO NOT dispose of electrical items or packaging as unsorted waste, use the recycling facilities provided by 

your local authorities. 

 

Due to our policy of continuous improvement we reserve the right to change specification without prior notice.    Errors and 

omissions excepted. These instructions have been carefully checked prior to publication. However, no responsibility can be 

accepted by Challenger for any misinterpretation of these instructions. 

 

E-Matic Energy Management Solutions   

Distributed by: Challenger Security Products 

10 Sandersons Way, 

Blackpool, FY4 4NB 

Email: [email protected] 

Web: www.e-matic.co.uk

 

Содержание PMFMC

Страница 1: ...EMatic_PMFMC_Instructions_Rev01 PMFMC Flush Microwave Sensor Instruction Manual Please read the instruction manual before installing and retain for the user maintenance engineer for future reference ...

Страница 2: ... the transmission power of a mobile phone or the output of a microwave oven IMPORTANT NOTE Installation must be performed by a skilled electrician who is familiar with the appropriate standards and technical requirements of the appliance and its proper installation The person carrying out the installation is to check and verify that the total load including in rush current on the circuit the ratin...

Страница 3: ...al valid trigger signal then the timer will re start and the light will remain on Adjusting SENS adjuster for desired the detection range Walk test immediately outside the area to ensure no detection or activation through walls and floors to minimize unwanted activations After testing the sensor ensuring the required area can be detected Turn the LUX adjuster to the required light operational leve...

Страница 4: ...1 5 3 5m Detection Moving Speed 0 6 1 5m s Time Delay Min 10sec 3sec Max 12min 1min Working Humidity 93 RH Working Temperature 20 40C Dimensions 75mmx76mm Hole Cut Out Size 62 65mm Weight 120g net IP Rating IP20 Rated Load Fluorescent Max 1200W Energy Saving Max 300W LED Max 300w or maximum 6 number of LED drivers Environment Please DO NOT dispose of electrical items or packaging as unsorted waste...