EMatic_PMFMC_Instructions_Rev01

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                 

 

 

 
 
 
 
 
 
 
 

Testing 

Turn  the  LUX  adjuster  fully  clockwise  (SUN);  turn  the  TIME  adjuster  fully  anti-clockwise  to  the 
minimum (10s). 

 

Switch on the AC supply and after a 30sec warm-up period 
the sensor will now be in test mode   

 

Walk  test  the  sensor,  when  the  sensor  receives  a  valid 
trigger  signal  within  its  detection  area  the  lamp  will  turn 
on.    If the sensor does not receive any other valid trigger 
signal then the light should switch off 10sec (±3sec). 

 

While the lamp is on and if the sensor receives additional 
valid trigger signal then the timer will re-start and the light will remain on. 

 

Adjusting SENS adjuster for desired the detection range.     

 

Walk  test  immediately  outside  the  area  to  ensure  no  detection  or  activation  through  walls  and 
floors to minimize unwanted activations. 

 

After  testing  the  sensor ensuring  the  required  area  can  be  detected, Turn  the  LUX  adjuster to the 
required light operational level, adjust the TIME adjuster clockwise to the required time for the light 
duration to be on. 

 
Troubleshooting 

 

The load does switch on: 

o

 

  Please check the connections, and the AC mains supply is on 

o

 

  Please check if the load is operational 

o

 

  Please check the adjustment settings and make the necessary adjustments if required 

 

Содержание PMFMC

Страница 1: ...EMatic_PMFMC_Instructions_Rev01 PMFMC Flush Microwave Sensor Instruction Manual Please read the instruction manual before installing and retain for the user maintenance engineer for future reference ...

Страница 2: ... the transmission power of a mobile phone or the output of a microwave oven IMPORTANT NOTE Installation must be performed by a skilled electrician who is familiar with the appropriate standards and technical requirements of the appliance and its proper installation The person carrying out the installation is to check and verify that the total load including in rush current on the circuit the ratin...

Страница 3: ...al valid trigger signal then the timer will re start and the light will remain on Adjusting SENS adjuster for desired the detection range Walk test immediately outside the area to ensure no detection or activation through walls and floors to minimize unwanted activations After testing the sensor ensuring the required area can be detected Turn the LUX adjuster to the required light operational leve...

Страница 4: ...1 5 3 5m Detection Moving Speed 0 6 1 5m s Time Delay Min 10sec 3sec Max 12min 1min Working Humidity 93 RH Working Temperature 20 40C Dimensions 75mmx76mm Hole Cut Out Size 62 65mm Weight 120g net IP Rating IP20 Rated Load Fluorescent Max 1200W Energy Saving Max 300W LED Max 300w or maximum 6 number of LED drivers Environment Please DO NOT dispose of electrical items or packaging as unsorted waste...

Отзывы: