64
Figure 5- 41
Please refer to the following sheet for detailed information.
Parameter
Function
Enable
After enabled, relay activation will work. Check it and enable the
PIR alarm.
Working
period
This function becomes activated in the specified periods.
There are six periods in one day. Please draw a circle to
enable corresponding period.
Select date. If you do not select, current setup applies to
today only. You can select all week column to apply to the
whole week.
Click OK button, system goes back to motion detection
interface; please click save button to exit.
Note: User can set via dragging mouse while not releasing left
mouse.
Anti-dither
System only memorizes one event during the anti-dither period.
The value ranges from 0s to 100s.
Flash
After enabling, the system will automatically turn on the flash
when alarm occurs.
Flash Delay
The flash will be off with a period of time delay when the
alarm linkage is over.
Time is calculated by unit of second and ranges from
10s~300s.
Record
System auto activates motion detection channel to record once
alarm occurs (working with motion detection function).
Record Delay System can delay the record for specified time after alarm ended.
The value ranges from 10s to 300s.
Relay out
Enable alarm activation function. You need to select alarm output
port so that system can activate corresponding alarm device when
alarm occurs.
Alarm delay
System can delay the alarm output for specified time after alarm
ended. The value ranges from 10s to 300s.
Send Email
After this function is enabled, system can send out email to alert
you when alarm occurs and ends.
Audio Linkage Check it and the system will play alarm audio file when alarm
occurs. Users can set recorded audio file in “Camera Setting
>
Audio
>
Alarm Audio”.
Snapshot
After you enabled snapshot, the system will automatically
snapshot if alarm occurs.