background image

 

 

23 

 

Figure 5-3 

 

Содержание ELI-SIP2-APTZ8-R30X

Страница 1: ...ss Setup 4 1 4 4 Baud Rate Parity Setup HD SD Video Mode Setup 5 1 4 5 Terminal Matched Resistance Setup 6 1 5 Reset and SD Card Installation network speed dome 6 1 6 Speed Dome Installation 7 Note 7...

Страница 2: ...allation 18 4 2 1 Installation Requirements 18 4 2 2 Installation Steps 18 5 CORNER MOUNT BRACKET INSTALLATION 21 5 1 Component Installation 21 5 2 Installation 21 5 2 1 Installation Requirements 21 5...

Страница 3: ...oblem in Practical Use 28 8 4 RS485 Bus FAQ 29 9 APPENDIX THE RELATIONSHIP BETWEEN THE 24V AC CABLE DIAMETER AND THE TRANSMISSION DISTANCE 30 10 APPENDIX THE RELATIONSHIP BETWEEN THE 12V DC CABLE DIAM...

Страница 4: ...iv Welcome Thank you for purchasing our speed dome Please read the following safeguards and warnings carefully before you install or use the product...

Страница 5: ...appliances shall have the enough capacity to reach the installation height The lifting appliances shall have safe performance The precaution measures include two types Warning and Note Warning It is t...

Страница 6: ...l injury or device damage resulting from opening the shell Please contact your local retailer if there is internal setup or maintenance requirement We are not liable for any problems caused by unautho...

Страница 7: ...Do not use gasoline dope thinner or other chemical material to clean the shell It may result in shell transfiguration or paint flake Do not allow the plastic or rubber material to touch the shell for...

Страница 8: ...upport the speed dome and its corresponding installation component It shall sustain the 8X weight of the speed dome Please notice that the installation height should be more than 6m if it is a laser s...

Страница 9: ...re shown in Figure 1 1 please refer to the actual object for details There is laser light and IR light on the laser speed dome the laser light is used for light compensation while the IR light can be...

Страница 10: ...d rate and parity Please refer to Figure 1 2 for the dial switch address Figure 1 2 1 4 1 2 HDCVI Speed Dome Open the cover of the speed dome you can see there are two dial switch buttons on the PTZ m...

Страница 11: ...is 1 when you set the button as ON For address setup dial switch 1 is the lowest bit 8 is the highest bit for the Baud rate and parity setup dial switch 1 is the lowest bit 4 is the highest bit Intel...

Страница 12: ...9600bps ON OFF 4800bps OFF ON 2400bps ON ON 1200bps Sheet 1 2 Please refer to the parity setup sheet 1 3 for detailed information 3 4 Parity OFF OFF NONE ON OFF EVEN OFF ON ODD ON ON NONE Sheet 1 3 1...

Страница 13: ...n 3 which means 120 resistance is not connected to the device Figure 1 8 If you want to connect the 120 resistance you have to pull the jumper out of pin 2 and pin 3 and connect to pin 1 and pin 2 the...

Страница 14: ...led information please refer to chapter 2 to chapter 6 Here we are going to install the analog speed dome with the analog speed dome wall mounted bracket 1 6 1 Quick Installation Connector Now you can...

Страница 15: ...d integration cable of the wall mount bracket to the corresponding power cable video audio cable RS485 control cable alarm port high frequency cable fiber cable if necessary of the multiple function c...

Страница 16: ...then push the speed dome to the bottom of the port slowly Step 3 Use your hands to turn the M6 14 stainless screw with spring washer to the 6 5 hole of the straight edge of the IR speed dome Turn othe...

Страница 17: ...10 Figure 1 14...

Страница 18: ...IMENSIONS 2 1 Wall Mount Bracket The wall mount bracket dimensions are shown as below See Figure 2 1 Figure 2 1 2 2 Hanging Mount Bracket Multiple Lengths The hanging mount bracket is shown as below S...

Страница 19: ...ure 2 2 Note The bracket length setup values are 200mm default 400mm optional You just need to replace the connection pole 2 3 Corner Mount Bracket The corner mount bracket is shown as below See Figur...

Страница 20: ...13 Figure 2 3 2 4 Pole Mount Bracket The pole mount bracket is shown as below See Figure 2 4...

Страница 21: ...14 Figure 2 4...

Страница 22: ...environments Before the installation please make sure The wall is thick enough to install the expansion bolt The wall can at least sustain the 8x weight of the speed dome 3 2 2 Installation Steps Ste...

Страница 23: ...16 Figure 3 2 Step 2 Install the IR speed dome in the bracket See Figure 3 3 Please refer to 1 6 Speed Dome Installation for more details...

Страница 24: ...17 Figure 3 3...

Страница 25: ...onments Before the installation please make sure The wall is thick enough to install the expansion bolt The wall can at least sustain the 8x weight of the speed dome 4 2 2 Installation Steps Step 1 Lo...

Страница 26: ...d to paste the silica gel on the surface of the connection plate and the ceiling and the cable exit Step 2 Pull the cable through the connection pole and then secure the connection pole to the connect...

Страница 27: ...ents you need to paste enough Teflon tape at the top screw thread of the connection pole and then turn the connection pole to the connection plate firmly Step 3 Please refer to chapter 1 6 for detaile...

Страница 28: ...olt The wall can at least sustain the 8x weight of the speed dome 5 2 2 Installation Steps Step 1 Please draw four holes position in the wall with a 90 degree angle according to the holes of the corne...

Страница 29: ...22 Figure 5 2 Step 2 Install speed dome according to Figure 5 3 please refer to 1 6 for more details about speed dome installation...

Страница 30: ...23 Figure 5 3...

Страница 31: ...comply with the installation dimension of the clamp Default factory clamp is 5 inches for the column of 80 130mm It can work with the pole installation bracket You can adjust the diameter and the val...

Страница 32: ...Note After the installation please make sure the clamp is firmly secure in case it may result in clamp broken Step 2 Please refer to chapter 1 6 for detailed information about speed dome installation...

Страница 33: ...26 Figure 6 3...

Страница 34: ...e point to the earth Open floor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additio...

Страница 35: ...transmission distance shall become longer 8 3 The Problem in Practical Use In practical usage we usually adopt star type connection The terminal resistance shall connect to the furthest two devices Su...

Страница 36: ...n cable is loose RS485 Bus connection are cut off Modify host or speed dome setup Switch RS485 positive end and negative end Fix connection cable firmly Replace RS485 Bus I can control the speed dome...

Страница 37: ...13 37 23 190 83 58 16 298 17 90 88 763 31 232 66 25 97 70 29 78 152 66 46 53 238 53 72 71 610 65 186 13 30 81 42 24 82 127 22 38 78 198 78 60 59 508 87 155 10 35 69 79 21 27 109 04 33 24 170 38 51 93...

Страница 38: ...31 mm Feet m w 0 8000 1 000 1 250 2 000 100 24 43 7 45 38 17 11 63 59 63 18 18 152 66 46 53...

Страница 39: ...20 30 53 9 31 47 71 14 54 74 54 22 72 190 83 58 16 25 24 43 7 45 38 17 11 63 59 63 18 18 152 66 46 53 30 20 35 6 20 31 80 9 69 49 69 15 15 127 22 38 78 35 17 45 5 32 27 26 8 31 42 60 12 98 109 04 33...

Страница 40: ...33 mm Feet m w 0 8000 1 000 1 250 2 000 100 6 11 1 86 9 54 2 91 14 91 4 54 38 17 11 63...

Страница 41: ...00950 0 130 36 39 0 01327 0 140 35 0 01539 0 160 34 37 0 02011 0 180 33 0 02545 0 200 32 35 0 03142 0 230 31 0 04115 0 250 30 33 0 04909 0 290 29 31 0 06605 0 330 28 30 0 08553 0 350 27 29 0 09621 0...

Страница 42: ...ware here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please re...

Отзывы: