Please keep speed dome package material well in case you need to send it back to your local
retailer or manufacturer for maintenance work.
Non-original package material may result in device damage during the transportation.
Check Accessories
Before the installation, please check the accessories one by one according to the packing list.
Please make sure all the components listed are includes.
1.2
Initial Setup
The default setup is:
Address: 1
Baud rate: 9600
Parity: None.
1.3
Dial Switch Setup (Analog Speed Dome)
1.3.1 Dial Switch Description
There are two dial switch buttons on the PCB of one side of the speed dome (There are labels.).
You can use them to set speed dome baud rate, address and etc. See Figure 1-1 . It is 1 when
you set the button as ON.
For the protocol dial switch, you can refer to the following sheet. 1 is the lowest bit and the 8 is
the highest bit. 1~3 is NC neutral bit, 4 is the setting bit for 120
Ω
matched resistance, ON is to
connect 120
Ω
matched resistance, 5, 6 are the setting bit for parity, 7, 8 are the setting bit for
baud rate. Only when you cut off the power or restart the system after dial switch setup, can the
setup be valid.
Note:
The IR speed dome can automatically recognize the PELCO-D. PELCO-P and industry
standard protocol, control protocol doesn
’t need to be set via dial.