GENERAL FEATURES
29
When enabled, the horn alert pulses on and off for 1-8 cycles and
then goes back to the disabled state. To change the currently selected horn
alert mode, the HORN option switch or HRN ALRT menu parameter can
be used if available (see page 32).
The horn alert is programmed to operate in the manual or automatic
mode (see descriptions which follow). If the ignition switch does not
control transceiver power, only the front panel power switch affects oper-
ation when applicable. Refer to “Power Turn-Off Delay” on page 30 for
more information.
Manual Off/On Mode
The horn alert mode does not change when power is turned on and
off by either the ignition switch or power switch. Therefore, the horn alert
is entirely controlled by either the HORN option switch or menu
parameter.
Auto Off/On Mode
Ignition Switch
-
The horn alert always turns off when the ignition switch
is turned on, and always turns on when the ignition switch is turned off (if
there is a turn-off delay).
Power Switch - The horn alert always reverts to the off condition when
power is turned on by the power switch.
NOTE: The preceding automatic operation overrides any mode that may
have been selected by the HORN option switch or HRN ALRT menu
parameter.
Option Select
The AUX switch or OPTION menu parameter can be used to control
an accessory that may have been installed by your system operator. If the
switch is used, the enabled condition is indicated by
in the display.