User Manual HTP201 Humidity and Temperature Probe with Analogue Outputs

5.3  Protection during Site Cleaning Operations

During site cleaning or sterilization process, if the HTP201 remains on the measuring site the sensing 

head can be protected with the optional protection cap for 12 mm 

(0.47")

 probe (HA010783, see 

datasheet “Accessories”).

In case the probe is removed from the site, it is recommended to apply the protection cap for the M12 

cable socket (HA010781) and the one for the HTP201 M12 plug of (HA010782).

Fig. 6 

Protection cap for 

Ø12 mm 

(0.47")

 probe

  

(ordering code 

HA010783)

Fig. 7 

Protection cap for 

M12 socket (ordering 

code HA010781)

Fig. 8 

Protection cap for 

M12 plug (ordering 

code HA010782)

5.4  Repairs

Repairs may be carried out by the manufacturer only. The attempt of unauthorized repair excludes any 

warranty claims.

5.5  Spare Parts

Description

Order code

Filter caps for probes 

with Ø12 mm

Please refer to the  

datasheet “Accessories“

6  Accessories

For further information see datasheet 

Accessories

.

General

Order code

M12x1 connector, 4 pole socket, for self assembly

HA010707

Connection cable, 5 pole, M12x1 plug / socket, shielded, 

2 m (6.6 ft) / 5 m (16.4 ft) /10 m (32.8 ft)

HA010816/HA010817/

HA010818

Connection cable, 5 pole, M12x1 socket / free ends, shielded,

1.5 m (4.9 ft) / 5 m (16.4 ft) / 10 m (32.8 ft)

HA010819/HA010820/

HA010821

Plastic mounting flange Ø12 mm (0.47") black

HA010214

Stainless steel flange Ø12 mm

HA010201

Plastic wall mounting clip Ø12 mm (0.47")

HA010211

Stainless steel wall mounting clip Ø12 mm (0.47")

HA010225

Protection cap for Ø12 mm (0.47") probe

HA010783

Protection cap for M12 socket

HA010781

Protection cap for M12 plug

HA010782

Radiation shield with fixed clamping ring (M20x1.5)

HA010502

Содержание HTP201

Страница 1: ...BA_HTP201 v1 0 Modification rights reserved User Manual HTP201 Humidity and Temperature Probe with Analogue Outputs ...

Страница 2: ... equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the in...

Страница 3: ... 5 3 1 General 5 3 2 Dimensions 6 3 3 Electrical Connection 7 3 3 1 M1 Models RH T 7 3 3 2 M6 Models RH T passive 8 4 Installation 8 4 1 Wall and Ceiling Mount 8 4 2 Duct Mount 8 4 3 Recommendations for accurate Humidity and Temperature Measurement 8 5 Maintenance and Service 9 5 1 Cleaning 9 5 2 Filter Cap Replacement 9 5 3 Protection during Site Cleaning Operations 10 5 4 Repairs 10 5 5 Spare Pa...

Страница 4: ...ection maintenance and commissioning shall be performed by qualified personnel only Use the HTP201 only as intended and observe all technical specifications Do not use HTP201 in explosive atmosphere or for measurement of aggressive gases 1 2 2 Intended Use The HTP201 is intended for highly accurate and cost effective humidity RH and temperature T measurement in demanding process applications The R...

Страница 5: ...ocess Service operations other than described in this user manual may only be performed by the manufacturer Disclaimer of Liability The manufacturer or their delegated representative is only liable in case of intent or gross negligence The accountability is limited to the value of the order issued at the time to the manufacturer The manufacturer is not liable for damages originated from disregardi...

Страница 6: ... 4 M12x1 11 0 43 12 0 5 106 4 2 12 0 5 34 1 3 Current versions With connector Type E9 With cable Type E8 131 5 2 12 0 5 34 1 3 12 0 5 34 1 3 127 5 M12x1 11 0 43 Fig 1 Dimensions of HTP201 in mm inch 44 1 73 Ø5 Ø0 2 20 0 79 20 0 79 1 5 0 06 122 4 8 44 1 73 Ø105 Ø4 13 174 6 85 94 3 7 Fig 2 Dimensions of optional radiation shield ordering code HA010502 in mm inch ...

Страница 7: ... 3 1 M1 Models RH T Voltage versions A1 A2 A3 With connector HTP201 M1xE9x Pin number Function 1 Supply voltage V 2 RH 3 GND 4 T M12 device plug front view 1 2 3 4 With cable HTP201 M1xE8x Supply voltage according to technical data V white GND brown RH green T yellow V V Current version A6 With connector HTP201 M1A6xE9 Pin number Function 1 Supply voltage V 2 RH 3 not connected 4 T M12 device plug...

Страница 8: ...ng on the connection cable Fig 3 Optional wall and ceiling mount ordering code HA010211 4 2 Duct Mount The probe also can be installed into a duct using the plastic flange HA010214 or the stainless steel flange HA010201 not included in the scope of supply see data sheet Accessories Fig 4 Optional plastic flange ordering code HA010214 Fig 5 Optional stainless steel flange ordering code HA010201 4 3...

Страница 9: ...surements especially over wide RH and T ranges it is recommended to calibrate the probe every 12 months If needed the enclosure or the sensing element may be cleaned as described below 5 1 Cleaning Use a damp soft cloth to remove deposits of dust or dirt from the exterior of the probe Do not use any solvents or abrasive cleaning agents In case of dusty oily and polluted environment Use a damp soft...

Страница 10: ...cturer only The attempt of unauthorized repair excludes any warranty claims 5 5 Spare Parts Description Order code Filter caps for probes with Ø12 mm Please refer to the datasheet Accessories 6 Accessories For further information see datasheet Accessories General Order code M12x1 connector 4 pole socket for self assembly HA010707 Connection cable 5 pole M12x1 plug socket shielded 2 m 6 6 ft 5 m 16...

Страница 11: ...y of the factory calibration with an enhancement factor k 2 2 times standard deviation The accuracy was calculated in accordance with EA 4 02 and with regard to GUM Guide to the Expression of Uncertainty in Measurement Temperature T Measuring range 40 80 C 40 176 F Accuracy Incl hysteresis non linearity and repeatability 0 5 0 6 0 4 0 3 0 2 0 1 T C T C Outputs Analogue RH 0 100 T 40 60 80 C see or...

Страница 12: ...e 1 5 m 4 9 ft 3 m 9 8 ft 5 m 16 4 ft PVC Ø4 3 mm 4 x 0 25 mm2 for RH T with voltage output Ø4 3 mm 3 x 0 25 mm2 for RH T with current output Ø4 8 mm 6 x 0 14 mm2 for RH T passive with current output Storage conditions 40 80 C 40 176 F 0 95 RH non condensing Material Enclosure Probe cable cable versions Polycarbonate PC or stainless steel 1 4404 Polyvinyl chloride PVC Protection rating IP65 Electr...

Страница 13: ...epluse fr E E Elektronik Germany Obere Zeil 2 61440 Oberursel Tel 49 6171 69411 0 E mail info epluse de E E Elektronik India 801 Sakhi Vihar Road 400072 Mumbai Tel 91 990 440 5400 E mail info in epluse com E E Elektronik Italy Via Alghero 17 19 20128 Milano MI Tel 39 02 2707 86 36 E mail info epluse it E E Elektronik Korea Suite 2001 Heungdeok IT Valley Towerdong 13 Heungdeok 1 ro Giheung gu 16954...

Отзывы: