E+E Elektronik EE895 Скачать руководство пользователя страница 4

User Manual EE895

Miniature Sensor Module for CO

2

 , Temperature and Barometric Pressure  |  4

1.2  Safety Instructions

1.2.1.  General Safety Instructions

NOTICE

Improper handling of the device may result in its damage.

▪ 

The EE895 housing and the circuit board shall not be exposed to unneccessary mechanical stress during 

installation and operation. The forces exerted shall not exceed 50 N.

▪ 

The EE895 electronics is sensitive to electrostatic discharge (ESD), appropriate protective measures shall 

be taken when touching it.

▪ 

Use the EE895 only as intended and observe all technical specifications.

1.2.2.  Intended Use

The EE895 miniature sensor module measures the CO

2

 concentration, the temperature (T) and the absolute 

barometric pressure (p). It is intended to be used as sensor module in devices for diverse uses in non-condensing 

environments. Applications can be , e.g., in building automation, demand controlled ventilation and process 

control.

 

WARNING

Non-compliance with the product documentation may cause safety risk for people and the entire 

measurement installation.
The manufacturer cannot be held responsible for damages as a result of incorrect handling, installation and 

maintenance of the device.

▪ 

Do not use EE895 in explosive atmosphere or for measurement of aggressive gases.

▪ 

This device is not appropriate for safety, emergency stop or other critical applications where device 

malfunction or failure could cause injury to human beings.

NOTICE

Failing to follow the instructions in this user manual may lead to measurement inaccuracy and device 

failures.

▪ 

The EE895 may only be operated under the conditions described in this user manual and within the 

specification included in chapter 5 Technical Data.

▪ 

The device may only be powered with safety extra-low voltage (SELV).

▪ 

Unauthorized product modification leads to loss of all warranty claims. 

1.2.3.  Mounting, Start-up and Operation

The EE895 has been produced under state of the art manufacturing conditions, has been thoroughly tested and 

has left the factory after fulfilling all safety criteria. The manufacturer has taken all precautions to ensure safe 

operation of the device. The user must ensure that the device is set up and installed in a way that does not impair 

its safe use. The user is responsible for observing all applicable local and international safety guidelines for 

safe installation and operation of the device. This user manual contains information and warnings that must be 

observed by the user in order to ensure safe operation.

 

PLEASE NOTE

The manufacturer or his authorized agent can be only be held liable in case of willful or gross negligence. 

In any case, the scope of liability is limited to the corresponding amount of the order issued to the 

manufacturer. The manufacturer assumes no liability for damages incurred due to failure to comply with the 

applicable regulations, operating instructions or the specified operating conditions. Consequential damages 

are excluded from the liability.

Содержание EE895

Страница 1: ...User Manual Miniature Sensor Module for CO2 Temperature and Barometric Pressure EE895...

Страница 2: ...2 1 Mounting via Solder Pads 7 3 2 2 Mounting via Side Plated Contacts 7 3 3 EE895 Block Diagram 8 3 5 Pin Description 9 3 6 Electrical Characteristics 11 3 7 Typical Applications 12 3 7 1 EE895 Conne...

Страница 3: ...NOTE Find this document and further product information on our website at www epluse com ee895 1 1 Explanation of Warning Notices and Symbols Safety precautions Precautionary statements warn of hazar...

Страница 4: ...tion or failure could cause injury to human beings NOTICE Failing to follow the instructions in this user manual may lead to measurement inaccuracy and device failures The EE895 may only be operated u...

Страница 5: ...t be separated according to local recycling regulations The electronics shall be disposed of correctly as electronics waste 1 4 ESD Protection The sensing elements and the electronics board are ESD el...

Страница 6: ...the instructions in this user manual may lead to measurement inaccuracy and device failures The EE895 housing and the circuit board shall not be exposed to unneccessary mechanical stress during instal...

Страница 7: ...he EE895 module can be mounted onto a pluggable female header or directly onto the electronics board by using a pin header with 2 54 mm 0 1 inch pitch The minimum clearance of 2 mm 0 08 inch shall be...

Страница 8: ...ter infra red lamp IR L 2 VCC_IO Power supply Power supply for the microcontroller 3 EN Input Enable the module Tie to Vcc_IO for normal operation 4 GND Power supply Ground1 5 GND Power supply Ground1...

Страница 9: ...s of the EN pin by an external host controller When the EN pin is pulled down to the logic Low 0 0 4 V the internal voltage regulator of EE895 is switched off and the current consumption is typically...

Страница 10: ...on the interface selected with pin 7 ISEL Pin 7 ISEL connected to ground EE895 features I2 C interface Pin no Mode Comment 8 SCL serial clock External pull up resistor to V bus high voltage level is r...

Страница 11: ...nd maximum current values in each individual state during the sampling interval which is shown in the current profile in Fig 8 Power Supply VCC_IO VCC_EM Status 3 3 V 5 V Idle measurement 6 2 9 9 mA 0...

Страница 12: ...ltage regulator The host can read the values at any time pin 6 RDY is not used 3 7 2 EE895 in Battery Powered Devices Fig 10 Example battery powerd devices Pin 7 ISEL is connected to the ground the EE...

Страница 13: ...described in detail in the Modbus Application Note AN0103 available at www epluse com ee895 4 1 I2 C Interface The EE895 supports the standard I2 C specification For detailed information about the I2...

Страница 14: ...value Lo CRC Stop S BF 03 04 00 00 41 DC 74 3F P For decoding of float values stored according standard IEEE 754 please refer also to the Modbus Application Note AN0103 Example of Decoding Modbus res...

Страница 15: ...130 means 1 013 mbar Tab 7 Data availability from the EE895 Miniature Sensor Module Example for reading all measurands 7 bit address shifted EE895 Request Hex S BC 00 P Start Slave address 7 bit shif...

Страница 16: ...e p 0x2670 9840 984 0 mbar Tab 9 Interpretation of data from the response 4 2 UART Interface 4 2 1 Modbus Protocol Over UART Interface Modbus slave address 0x5F The interface settings are Baud rate 96...

Страница 17: ...Register number1 DEC Protocol address2 HEX Read register function code 0x03 Temperature T C 100 4002 0xFA1 Temperature T F 50 4003 0xFA2 Temperature T K 50 4005 0xFA4 CO2 average pc4 ppm 1 4031 0xFBE...

Страница 18: ...s 0 terminated 1 Register address starts from 0 Tab 13 Available commands for I2 C and UART PLEASE NOTE When reading the serial number or the sensor name it is always necessary to read all 8 registers...

Страница 19: ...ble Measuring trigger command for the single shot measurement For accurate measurement results there are recommended six single shot measurements under stable temperature conditions Function code Regi...

Страница 20: ...fault 4 0x1452 CO2 customer offset ppm 16 bit integer signed Range 32 786 32 785 Default 0 ppm 1 Register address starts from 0 Tab 18 CO2 parameter settings The EE895 features an exponential moving a...

Страница 21: ...Residual pressure dependency2 typ 0 014 of the measured value mbar ref to 1 013 mbar Initialisation time power on 1 s Response time t63 140 s with measured data averaging smooth output 75 s without m...

Страница 22: ...ltage 3 3 5 V DC 5 Average current consumption typ for supply voltage 5 V 1 6 mA at 15 s sampling interval 196 A at 1 h sampling interval with standby between measurements 8 A at 1h sampling interval...

Страница 23: ...ance SARL T 33 4 74 72 35 82 info fr epluse com E E Elektronik Deutschland GmbH T 49 6171 69411 0 info de epluse com E E Elektronik India Private Limited T 91 990 440 5400 info in epluse com E E Elekt...