background image

QUICK GUIDE

EE8915 - CO

2

 Sensor for Railway Applications

Find this document and further product information on our website at www.epluse.com/EE8915.

CONNECTION DIAGRAM

FIX INSTALLED CABLE 

 

M12 CONNECTOR 

Core number Function

1

10 - 35 V DC supply

2

GND supply

3

GND analogue output

4

Current output

5

Voltage output

  

mA

2

4

5

1
3

V

+

-

Voltage output

Current output

GND analogue output

Power supply 10 - 35 V DC*

GND

M12 device plug

front view

1

2

3

4

5

*The supply circuit must be fused with 

 8A

ERROR INDICATION ON THE ANALOGUE OUTPUT

The EE8915 features an error indication on the analogue output according to NAMUR recommendations (factory setting: disabled).

The feature can be enabled with the EE-PCS Product Configuration Software, see full user guide at 

www.epluse.com/EE8915

.

Output signal

NAMUR signal level

0-5 V

5.5 V

0-10 V

11 V

4-20 mA

21 mA

0-20 mA

21 mA

STATUS LEDs

Green LED

Red LED

 

Green LED

flashing  = Normal operation

Red LED 

off

= Normal operation

on

= Failure. Contact E+E after sales service.

flashing

= Failure. Also indicated on the analogue output (NAMUR indication  

  enabled). The failure might be temporary, caused for instance by  

  overheating. If the flashing persists, contact E+E after sales service.

Important note:

 

»  The manufacturer cannot be held responsible for personal injuries or damage to property as a result of incorrect  

  handling, installation, wiring, power supply and maintenance of the device.  

»  For failure-free operation and performance according to the specs, the GND supply and the GND analogue output  

  must be wired separately. Internally, the GNDs are connected to each other on the electronics board.

Отзывы: