DIMENSIONS 

 

MODEL T1 (WALL MOUNT) 

MODEL T2 (DUCT MOUNT 0°) 

MODEL T27 (DUCT MOUNT 90°)

85 

(3.35")

98 

(3.86")

48 

(1.89")

35 

(1.38")

Ø4.5 

(0.18")

207.7 or 57.7 (8.18 or 2.27")

Ø12 

(0.47")

178.7 or 28.7

 

(7.04 or 1.30")

39.8 

(1.57")

INSTALLATION

WALL MOUNT

Choose a location which minimizes the dust deposits on the filter. 

DUCT MOUNT 

 

 

 

The arrows on the enclosure indicate the flow direction. 

When correctly installed, a small 

amount of air flows through the divided probe into the EE8915 enclosure, where the CO

2

 

sensing cell is located, and back into the duct.

Very important

For accurate measurement and response time according to specification:

 

»

Minimum air speed in the duct shall be 1 m/s (196 ft/m).

 

»

The air flow shall be perpendicular to the opening holes on the head of probe. 

Rubber gasket
Optional mounting flange

OR

Filter

CORRECT

INCORRECT

CORRECT

INCORRECT

 

MODEL T2 

MODEL T27

(0.31")

10 

(0.39")