E+E Elektronik EE870 Скачать руководство пользователя страница 2

2

For technical data, options and accessories please see EE870 data sheet at www.epluse.com/EE870

The modular CO

2

 transmitter EE870 consists of following components:

• 

EE871 interchangeable CO

2

 probe with E2 digital output. For technical data please see EE871 data sheet 

(www.epluse.com/EE871)  

For readjustment of EE871 please see data sheet and operation manual EE-PCS Product Configuration Software 

(www.epluse.com/EE-PCS)

• 

HA011014 converter board. The converter board supplies the EE871 CO

2

 probe and converts its 

digital output signal into analog outputs and Modbus RTU digital interface. The measured data is available  

simultaneously on the analogue outputs and on the Modbus interface.  Technical data, setup and operations 

instructions for HA011014 are detailed in this document.

• 

Connecting cable between EE871 CO

2

 probe and HA011014. EE870 scope of supply includes one of the following 

cables, as ordered:

• 

HA010810 ...........2m length

• 

HA010811 ...........5m length

• 

HA010812 .........10m length

GENERAL

General

 

Supply voltage 

10-35VDC  

  

10-28.8VAC

 

Supply current 

300mA at 10VDC 

 

 

120mA at 24VDC

 

Dimmensions of circuit board 

78 x 48 x 25.8mm 

 (0.26 x 0.16 x 1.02ft)

 

Pobe cable lenght 

max. 10m 

 (32.8ft)

 

Temperature working range 

-40...60°C

 (-40...140°F)

 

Protection class 

IP00

Analog Output 

 

Voltage-/ 

0-1V; 0-5V; 0-10V 

-1mA < I

L

 < 1mA 

 

Current outputs 

0-20mA; 4-20mA 

R

L

 < 500Ohm

 

Conversion rate 

Output value is updated every 200ms

 Resolution 

12bit

 

D/A Conversion accuracy 

Voltage output: 

+/- 10mV 

 

 

Current output: 

+/- 30μA 

 

Temperature dependence 

Voltage: 

typ. ±200ppm / °C 

 

 

Current: 

typ. ±1μA / °C

 

Long-term stability 

Drift < 0,2% / year

Modbus

 

Register 

see Modbus Map

Modbus connections

 

Connecting the supply voltage to the modubs terminals may destroy thedevice.

HA011014 converter board

  

is supplied as a component and must be installed in accordance with the valid ESD 

 

guidelines and properly protected against enviromental influences.

TECHNICAL DATA

IMPORTANT NOTES

66 

(2.6“)

3.2 

(1.13“)

(0.24“)

(0.24“)

39 

(1.54“)

4.5 

(0,18“)

4.5 

(0,18“)

25.8 

(1.02“)

13.8 

(0.55“)

78 

(3.08“)

+5V

white

SCL

black

SDA

blue

GND

brown

Shield grey

analog outputs

Jumper "Fast/Slow"

Jumper "Output Range"

Terminals for cable EE871

Modbus terminals

Modbus-Dipswitch

supply terminal

LED:

on 

= OK

fast flash 

= Error

Conversion Board

Digital CO

2

 Probe EE871

96 

(3.78“)

18.5 

(0.73“)

M12x1

Gewicht: 30g

Weight: 30g (1.06oz)

CONNECTIONS / MOUNTING

Отзывы: