E+E Elektronik EE820 Скачать руководство пользователя страница 5

User Manual EE820

CO

2

 Sensor for Demanding Applications  |  5

 

WARNING

Non-compliance with the product documentation may cause accidents, personal injury or property damage.

▪ 

 Mounting, installation, commissioning, start-up, operation and maintenance of the device may be 

performed by qualified staff only. Such staff must be authorized by the operator of the facility to carry out 

the mentioned activities.

▪ 

The qualified staff must have read and understood this user manual and must follow the instructions 

contained within.

▪ 

All process and electrical connections shall be thoroughly checked by authorized staff before putting the 

device into operation.

▪ 

Do not install or start-up a device supposed to be faulty. Make sure that such devices are not accidentally 

used by marking them clearly as faulty.

▪ 

A faulty device shall be removed from the process.

▪ 

Service operations other than described in this user manual may only be performed by the manufacturer. 

1.3  Environmental Aspects

 

PLEASE NOTE

Products from E+E Elektronik Ges.m.b.H. are developed and manufactured in compliance with all relevant 

environmental protection requirements. Please observe local regulations for the disposal of the device.

For disposal, the individual components of the device must be separated according to local recycling 

regulations. The electronics shall be disposed of correctly as electronics waste.

2  Scope of Supply

▪ 

EE820 - CO

2

 Sensor for Demanding Applications according to ordering guide

▪ 

Mounting set (screws and rowl plugs / screw anchors)

▪ 

Cable gland (only for EE820-HVxxxE1xxx with cable gland)

▪ 

M12x1 cable connector for self assembly (for option AC2 only)

▪ 

Test report according to DIN EN 10204-2.2

3  Product Description

3.1  General

The EE820 CO2 sensor is optimized for use in demanding applications, such as hatchers, incubators, life stock 

barns or greenhouses.
The sensor is designed for indoors and outdoors application in non-explosive environment with atmospheric 

pressure and under all non-condensing humidity conditions.
The sensor enclosure is IP54 protected with a special filter for installation in even harsh environment.
Power supply and output are possible via cable gland or M12 connector (see chapter 4.2 Electrical Connection for 

details).
For a setup deviating from default, the EE820 can be configured manually . Please refer to chapter 5 Setup and 

Configuration for details.

Содержание EE820

Страница 1: ...User Manual CO2 Sensor for Demanding Applications EE820...

Страница 2: ...Mounting and Installation 6 4 1 General 6 4 2 Electrical Connection 6 4 2 1 EE820 with Cable Gland 7 4 2 2 EE820 with M12 Plug 7 4 2 3 EE820 with conduit connection 8 5 Setup and Configuration 8 5 1...

Страница 3: ...document and further product information on our website at www epluse com ee820 1 1 Explanation of Warning Notices and Symbols Safety precautions Precautionary statements warn of hazards in handling...

Страница 4: ...The device may not be manipulated with tools other than specifically described in this manual NOTICE Failing to follow the instructions in this user manual may lead to measurement inaccuracy and devic...

Страница 5: ...levant environmental protection requirements Please observe local regulations for the disposal of the device For disposal the individual components of the device must be separated according to local r...

Страница 6: ...results the EE820 must be installed in an environment where the medium to be measured flows sufficiently around the sensor shall not be placed near influencing objects such as heating radiators or fa...

Страница 7: ...ny wiring inside the device The external mounting holes allow the device to be mounted without opening the front cover The mating M12x1 cable plug for self assembly is included in the scope of supply...

Страница 8: ...If needed the user can change the factory setup by using the Product Configuration Software EE PCS available for free download at www epluse com configurator and the optional USB Configuration Adapte...

Страница 9: ...ng the USB configuration adapter 3 Start the EE PCS software 4 Follow the instructions on the EE PCS opening page for scanning the ports and identifying the connected device 5 Click on the desired set...

Страница 10: ...these might affect the enclosure and the labels Do not attempt to clean the filter on the front cover as it would only lead to its faster clogging Protection caps for M12 connector are available to pr...

Страница 11: ...2 000 0 5 000 0 10 000 ppm 0 10 V 1mA IL 1 mA IL load current 4 20 mA RL 500 RL load resistance General Power supply class III USA Canada Class 2 supply necessary max voltage 30 V DC 24 V DC 20 15 35...

Страница 12: ...adio frequency energy and if not installed and used in accordance with the installation manual may cause harmful interference to radio communications However there is no guarantee that interference wi...

Страница 13: ...User Manual EE820 CO2 Sensor for Demanding Applications 13...

Страница 14: ...ance SARL T 33 4 74 72 35 82 info fr epluse com E E Elektronik Deutschland GmbH T 49 6171 69411 0 info de epluse com E E Elektronik India Private Limited T 91 990 440 5400 info in epluse com E E Elekt...