1.2  Safety Instructions

1.2.1.  General Safety Instructions

NOTICE

Improper handling of the device may result in its damage.

▪ 

The EE820 enclosure, the sensing probe and the sensing module shall not be exposed to unnecessary 

mechanical or thermal stress.

▪ 

Use the EE820 only as intended and observe all technical specifications.

1.2.2.  Intended Use

The EE820 is a CO

2

 sensor for harsh and demanding applications, such as hatchers, incubators, life stock barns 

or greenhouses. The sensor is designed for indoors and outdoors application in non-explosive environment with 

atmospheric pressure and under all non-condensing humidity conditions.

 

WARNING

Non-compliance with the product documentation may cause safety risk for people and the entire 

measurement installation.
The manufacturer cannot be held responsible for damages as a result of incorrect handling, installation, and 

maintenance of the device.

▪ 

Do not use EE820 in explosive atmosphere or for measurement of aggressive gases.

▪ 

The sensor shall not be exposed to extreme mechanical or thermal stress.

▪ 

For use in polluted, dirty environment is essential to close tightly the sensor cover as well as the cable 

gland or conduit adapter in order to avoid pollution ingress into the enclosure.

▪ 

This device is not appropriate for safety, emergency stop or other critical applications where device 

malfunction or failure could cause injury to human beings.

▪ 

The device may not be manipulated with tools other than specifically described in this manual.

NOTICE

Failing to follow the instructions in this user manual may lead to measurement inaccuracy and device 

failures.

▪ 

The EE820 may only be operated under the conditions described in this user manual and within the 

specification included in chapter 7 Technical Data.

▪ 

Unauthorized product modification leads to loss of all warranty claims. Modification may be accomplished 

only with an explicit permission of E+E Elektronik Ges.m.b.H.!

1.2.3.  Mounting, Start-up and Operation

The EE820 has been produced under state of the art manufacturing conditions, has been thoroughly tested and 

has left the factory after fulfilling all safety criteria. The manufacturer has taken all precautions to ensure safe 

operation of the device. The user must ensure that the device is set up and installed in a way that does not impair 

its safe use. The user is responsible for observing all applicable local and international safety guidelines for 

safe installation and operation of the device. This user manual contains information and warnings that must be 

observed by the user in order to ensure safe operation.

 

PLEASE NOTE

The manufacturer or his authorized agent can be only be held liable in case of willful or gross negligence. 

In any case, the scope of liability is limited to the corresponding amount of the order issued to the 

manufacturer. The manufacturer assumes no liability for damages incurred due to failure to comply with the 

applicable regulations, operating instructions or the specified operating conditions. Consequential damages 

are excluded from the liability.

Содержание EE820

Страница 1: ...User Manual CO2 Sensor for Demanding Applications EE820...

Страница 2: ...Mounting and Installation 6 4 1 General 6 4 2 Electrical Connection 6 4 2 1 EE820 with Cable Gland 7 4 2 2 EE820 with M12 Plug 7 4 2 3 EE820 with conduit connection 8 5 Setup and Configuration 8 5 1...

Страница 3: ...document and further product information on our website at www epluse com ee820 1 1 Explanation of Warning Notices and Symbols Safety precautions Precautionary statements warn of hazards in handling...

Страница 4: ...The device may not be manipulated with tools other than specifically described in this manual NOTICE Failing to follow the instructions in this user manual may lead to measurement inaccuracy and devic...

Страница 5: ...levant environmental protection requirements Please observe local regulations for the disposal of the device For disposal the individual components of the device must be separated according to local r...

Страница 6: ...results the EE820 must be installed in an environment where the medium to be measured flows sufficiently around the sensor shall not be placed near influencing objects such as heating radiators or fa...

Страница 7: ...ny wiring inside the device The external mounting holes allow the device to be mounted without opening the front cover The mating M12x1 cable plug for self assembly is included in the scope of supply...

Страница 8: ...If needed the user can change the factory setup by using the Product Configuration Software EE PCS available for free download at www epluse com configurator and the optional USB Configuration Adapte...

Страница 9: ...ng the USB configuration adapter 3 Start the EE PCS software 4 Follow the instructions on the EE PCS opening page for scanning the ports and identifying the connected device 5 Click on the desired set...

Страница 10: ...these might affect the enclosure and the labels Do not attempt to clean the filter on the front cover as it would only lead to its faster clogging Protection caps for M12 connector are available to pr...

Страница 11: ...2 000 0 5 000 0 10 000 ppm 0 10 V 1mA IL 1 mA IL load current 4 20 mA RL 500 RL load resistance General Power supply class III USA Canada Class 2 supply necessary max voltage 30 V DC 24 V DC 20 15 35...

Страница 12: ...adio frequency energy and if not installed and used in accordance with the installation manual may cause harmful interference to radio communications However there is no guarantee that interference wi...

Страница 13: ...User Manual EE820 CO2 Sensor for Demanding Applications 13...

Страница 14: ...ance SARL T 33 4 74 72 35 82 info fr epluse com E E Elektronik Deutschland GmbH T 49 6171 69411 0 info de epluse com E E Elektronik India Private Limited T 91 990 440 5400 info in epluse com E E Elekt...

Отзывы: