WALL MOUNTING:

COLD WEATHER OPTION ONLY

WIRING DIAGRAMS:

Figure 5

Figure 4

CEILING MOUNTING WITH SURFACE 
MOUNTED CONDUIT

Transformer power Connector
        (male)

 

Black (for 120V)

 

Junction Box (Not Provided)

 

 

Page 3 of 4

Green (Ground wire)

 

Back plate

 

Screw (#8-32*0.875")

 

Heater power connector 
          (male)

 

White (Neutral)

 

Red or Orange (for 277V)

 

120VAC

 

0V NEUTRAL

 

277VAC

 

Transformer power 
Connector (female)

 

Frame

 

Battery
Connector

 

Heater connector 
     (female)

 

120VAC

 

0V NEUTRAL

 

277VAC

 

GROUND (GREEN)

 

    Green
(Ground wire)

 

Black (for 120V)

 

White (Neutral)

 

Red or Orange (for 277V)

 

Screw (#8-32*0.875")

 

Heater power connector 
          (male)

 

Transformer power 
Connector (male)

Back plate

 

JUMPER

 

Heater power
connector (female)

 

Printed
Circuit Board

 

*Note :
   1. 2pcs short circuit connector in the accessory bag.
   
  
 

 

   
  
 

 

   2. For 120Vac input connection, short circuit connector
       insert in female connector marked JUMPER in slots
       1 and 2.
  
 

 

3. For 277Vac input connection, short circuit connector 
    insert in female connector marked JUMPER in slots
    2 and 3.

 

1

 

1

 

2

 

2

 

3

 

3

 

Black(120Vac)

 

Red(277Vac)

 

PCBA

BAT

   Transformer
 Power Connector

   Transformer

 

   LED

 

   

Heater 

Power Connector

Jumper (See *Note)

Heater

 

Temperature Sensor

 

Front Cover

 

LED Module

 

LENS

 

Front Cover

LED Module

LENS

Содержание E-XML4 Series

Страница 1: ...wire nut 1 Separate front cover from back plate with a flat blade screwdriver Open from top slot first and then from side slots gently See Figure1 2 Remove knock out hole in the center of the back plate Remove knock out slots on the back plate that correspond to the size of the junction Box 3 Feed AC supply leads through the center hole in the back plate Then make the proper electrical connections...

Страница 2: ... female White Neutral Red or Orange for 277V Printed Circuit Board Transformer power Connector male Battery Connector Front cover assembly Frame Black for 120V White Neutral Red or Orange for 277V Screw 8 32 0 875 Transformer power Connector male Back plate 120VAC 0V NEUTRAL 277VAC GROUND GREEN Green Ground wire Page 2 of 4 PCBA BAT Transformer Power Connector Transformer LED Front Cover LED Modul...

Страница 3: ...k for 120V White Neutral Red or Orange for 277V Screw 8 32 0 875 Heater power connector male Transformer power Connector male Back plate JUMPER Heater power connector female Printed Circuit Board Note 1 2pcs short circuit connector in the accessory bag 2 For 120Vac input connection short circuit connector insert in female connector marked JUMPER in slots 1 and 2 3 For 277Vac input connection short...

Страница 4: ...lf testing and a 90 minute discharge once every 365 days after AC power has been supplied for a minimum of 24 hrs SERVICE INDICATION MANUAL TESTING WARNING The unit also provides for manual testing by pushing the test button in a specific pattern n o i t a c i d n I D E L n o i t c a e R n o i t c A Push test button Once within 2 seconds 30 second test FLASHING Green Push test button Twice within ...

Отзывы: