INSTALLATION INSTRUCTIONS

LED Wall Pack & Floodlight 

E-WF Series

2014-12-18

www.e-conolight.com      |     888.243.9445     |     FAX: 262.504.5409

CAUTIONS

DIRECT MOUNTING TO JUNCTION BOX

1.  Remove the rear mounting plate by loosening the two 

Allen head set screws from bottom of the plate using the 

provided wrench.

2.  Fasten the mounting plate to a recessed outlet box or other 

mounting surface.  Use the integrated bubble leveler to 

ensure that the plate is level.

3. 

Splice the power leads from the back of the fixture to the 

branch circuit leads from the junction box.  Attach black 

to black (hot), white to white (neutral), and green to green 

(ground).  Push the splices into the junction box.

4. 

Align the fixture against the mounting plate and retighten 

the set screws to secure the fixture in place.  

5.  For wet locations, caulk between the rear housing and the 

mounting surface to prevent water from entering the fixture 

from behind.

1.  Remove the rear mounting plate by loosening the two 

Allen head set screws from bottom of the plate using the 

provided wrench. Discard the mounting plate.

2.  Attach the wiring box to the desired location using the bolt 

holes provided.

3.  Remove the threaded plug(s) and route electrical conduit to 

the holes desired.  Feed the branch circuit wires through the 

conduit into the wiring box.

4. 

Splice the fixture power leads to the power leads inside the 

wiring compartment box – black to black (hot), white to white 

(neutral), and green to green (ground).

5. 

Align the fixture against the wiring box and tighten the set 

screws to secure the fixture in place. Take care to not pinch 

the wires.

1.  Remove the rear mounting plate by loosening the two 

Allen head set screws from bottom of the plate using the 

provided wrench. Discard the mounting plate. 

2. 

Splice the fixture power leads to the power leads inside the 

wiring compartment box – black to black (hot), white to white 

(neutral), and green to green (ground).

3. 

Align the wiring box against the back of the fixture and 

tighten the set screws to secure it in place.

Using 2" Slip Fitter:

4. 

Splice the fixture power leads to the branch circuit power 

leads and push the splices inside the pole.

5. 

Slide the slip fitter onto the end of the pole, rotate to the 

desired position, and tighten the  two Allen head set screws 

with 3/16” Allen wrench to 10 ft. lbs. (13.5 N•m).

6. 

Unscrew the Phillips head screws in the side of the slip fitter 

and remove the cover and O-ring.

7. 

Loosen the hex bolt inside the hinge, adjust the fixture to the 

desired angle, and securely retighten the bolt. Replace the 

O-ring and cover.

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety 

precautions should always be followed including the 

following:

READ AND FOLLOW ALL SAFETY 

INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before 

installation.

DANGER

 – Risque de choc – Couper l’alimentation 

avant l’installation.

2.  This luminaire must be installed in accordance with the 

NEC or your local electrical code. If you are not familiar 

with these codes and requirements, consult a qualified 

electrician. 

Ce produit doit être installé conformément à NEC ou 

votre code électrique local. Si vous n’êtes pas familier 

avec ces codes et ces exigences, veuillez contacter un 

électricien qualifié.

3. 

This floodlight is for outdoor use and should not be 

used in areas of limited ventilation or high ambient 

temperature.

Pour une utilisation en extérieur et ne doit pas être utilisé 

dans les zones de ventilation limitée ou température 

ambiante élevée

SAVE THESE INSTRUCTIONS FOR FUTURE 

REFERENCE 

E-WF1

Notes:

1.  The LED module is preinstalled and prepositioned. DO 

NOT OPEN the unit. 

2. 

DO NOT touch the surface of the LED’s. This fixture can 

be mounted with the lens in the up or down position.

3.  LED units are multi-volt 120V-277V.  No additional tap 

wires are necessary.

WALL-MOUNTED WIRING BOX WITH CONDUIT 

FEED

POLE MOUNT 

E-WF2

Отзывы: