Document:
Date
Created By:
DCR#
LPN00290X0001A1_A
TMT
2015-116
INSTALLATION INSTRUCTIONS
LED Wall Pack & Floodlight
E-WF Series
2014-12-18
www.e-conolight.com | 888.243.9445 | FAX: 262.504.5409
CAUTIONS
DIRECT MOUNTING TO JUNCTION BOX
1. Remove the rear mounting plate by loosening the two
Allen head set screws from bottom of the plate using the
provided wrench.
2. Fasten the mounting plate to a recessed outlet box or other
mounting surface. Use the integrated bubble leveler to
ensure that the plate is level.
3.
Splice the power leads from the back of the fixture to the
branch circuit leads from the junction box. Attach black
to black (hot), white to white (neutral), and green to green
(ground). Push the splices into the junction box.
4.
Align the fixture against the mounting plate and retighten
the set screws to secure the fixture in place.
5. For wet locations, caulk between the rear housing and the
mounting surface to prevent water from entering the fixture
from behind.
1. Remove the rear mounting plate by loosening the two
Allen head set screws from bottom of the plate using the
provided wrench. Discard the mounting plate.
2. Attach the wiring box to the desired location using the bolt
holes provided.
3. Remove the threaded plug(s) and route electrical conduit to
the holes desired. Feed the branch circuit wires through the
conduit into the wiring box.
4.
Splice the fixture power leads to the power leads inside the
wiring compartment box – black to black (hot), white to white
(neutral), and green to green (ground).
5.
Align the fixture against the wiring box and tighten the set
screws to secure the fixture in place. Take care to not pinch
the wires.
1. Remove the rear mounting plate by loosening the two
Allen head set screws from bottom of the plate using the
provided wrench. Discard the mounting plate.
2.
Splice the fixture power leads to the power leads inside the
wiring compartment box – black to black (hot), white to white
(neutral), and green to green (ground).
3.
Align the wiring box against the back of the fixture and
tighten the set screws to secure it in place.
Using 2" Slip Fitter:
4.
Splice the fixture power leads to the branch circuit power
leads and push the splices inside the pole.
5.
Slide the slip fitter onto the end of the pole, rotate to the
desired position, and tighten the two Allen head set screws
with 3/16” Allen wrench to 10 ft. lbs. (13.5 N•m).
6.
Unscrew the Phillips head screws in the side of the slip fitter
and remove the cover and O-ring.
7.
Loosen the hex bolt inside the hinge, adjust the fixture to the
desired angle, and securely retighten the bolt. Replace the
O-ring and cover.
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1. DANGER
- Risk of shock- Disconnect power before
installation.
DANGER
– Risque de choc – Couper l’alimentation
avant l’installation.
2. This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou
votre code électrique local. Si vous n’êtes pas familier
avec ces codes et ces exigences, veuillez contacter un
électricien qualifié.
3.
This floodlight is for outdoor use and should not be
used in areas of limited ventilation or high ambient
temperature.
Pour une utilisation en extérieur et ne doit pas être utilisé
dans les zones de ventilation limitée ou température
ambiante élevée
SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE
E-WF1
Notes:
1. The LED module is preinstalled and prepositioned. DO
NOT OPEN the unit.
2.
DO NOT touch the surface of the LED’s. This fixture can
be mounted with the lens in the up or down position.
3. LED units are multi-volt 120V-277V. No additional tap
wires are necessary.
WALL-MOUNTED WIRING BOX WITH CONDUIT
FEED
POLE MOUNT
E-WF2