INSTALLATION INSTRUCTIONS

LED Radial Wall Sconce

E-RS Series

www.e-conolight.com      |     888.243.9445     |     FAX: 262.504.5409

CAUTIONS

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety 

precautions should always be followed including the 

following:

READ AND FOLLOW ALL 

SAFETY INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before 

installation.

DANGER – Risque de choc – Couper l’alimentation 

avant l’installation.

2.  This luminaire must be installed in accordance with the 

NEC or your local electrical code. If you are not familiar 

with these codes and requirements, consult a qualified 

electrician. 

Ce produit doit être installé conformément à NEC ou votre 

code électrique local. Si vous n’êtes pas familier avec ces 

codes et ces exigences, veuillez contacter un électricien 

qualifié.

3.  Wall Mount Only.  

Installation Murale Seulement.

SAVE THESE INSTRUCTIONS 

FOR FUTURE REFERENCE 

1.  Remove the rear mounting plate by removing the (2) Phillips head 

screws located on the lower flange of fixture. Do NOT pull cord out 

of grommet in mounting plate. See 

Figure 1.

2. 

While supporting fixture and mounting plate, splice the power 
leads from the cord to the branch circuit leads in the junction box. 

Attach black to black (hot), white to white (neutral) and green to 

green (ground). Push the splices into the junction box. See 

Figure 

2.

3.  Remove only two appropriate plugs from the back plate for 

mounting over the corresponding junction box. Leave all other 

plugs in place.

4. 

Attach the rear mounting plate to the junction box using supplied 

screws and o-rings. For wet locations, caulk between rear gasket 
and mounting surface to prevent water from entering junction 

box area. A high grade caulking material such as silicone rubber 

should be used. See 

Figure 3.

DIRECT MOUNTING TO JUNCTION BOX

FIGURE 1

Notes:

 

1. 

Fixture is intended to operate at 120-277 VAC only.

2. 

Fixture  is  intended  to  be  mounted  over  3  1/2"  or  4"  octagon 

recessed  junction  box  or  4"  square  junction  box,  supplied  by 

customer.

FIGURE 2

FIGURE 3