background image

See3CAM_CU51 

 

        Application User Manual 

    

             06-August-2015 

 

 

 

 

www.e-consystems.com

 | Subject to change without notice 

Page 7 of 21 

6.1  Devices Menu 

Devices menu will show the currently connected video devices to host PC and the user can select 
any video devices attached to the computer. A check mark is placed before the device indicating 
the  video  device  which  is  currently  streaming.  By  default  See3CAM_CU51  device  will  be 
indicated by the name 

See3CAM_CU51

. In case any other video device is connected such as on-

board webcam etc., the e-CAMView shall list down those video capture devices as well and the 
user can switch between the available video capture devices, by selecting the respective device. 
 
There is no audio capture source available with the See3CAM_CU51. The following menu shows 
only our camera being listed in the Devices menu.  
 

 

 

Figure 2: Enumerated Devices list 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание See3CAM CU51

Страница 1: ...m Subject to change without notice Page 1 of 21 e con Systems India Pvt Ltd RISHABH INFO PARK RR Tower IV 7th Floor Super A 16 A 17 Thiru Vi Ka Industrial Estate Guindy Chennai 600 032 www e consystem...

Страница 2: ...rivers 5 6 Using e CAMView 6 6 1 Devices Menu 7 6 2 Options Menu 8 6 2 1 Video Capture Filter 8 6 2 2 Video Capture Pin 10 6 2 3 Still Capture Pin 11 6 2 4 Freeze frame 12 6 3 Capture Menu 13 6 4 Exte...

Страница 3: ...ajor Changes Author Initial Draft 13 August 2014 Initial Draft Raghavan N S 1 1 28 November 2014 Updated Product name updated 120 fps in VGA and changed extension menu image Raghavan N S 1 2 24 Decemb...

Страница 4: ...n will receive the 12bits of greyscale information for every pixel The application developer gets the very high resolution 12bpp data for every pixel for performing accurate image processing functions...

Страница 5: ...steps to initialize the device with the host computer Connect the one end of the USB 3 0 cable to the USB 3 0 connector provided at the back of See3CAM_CU51 and connect the other end to the USB 3 0 h...

Страница 6: ...CAMView This version of e CAMView comes with a set of features that can be used to attain the full functionality of See3CAM_CU51 The Menu bar at the top contains few menu items and the lower status ba...

Страница 7: ...video device which is currently streaming By default See3CAM_CU51 device will be indicated by the name See3CAM_CU51 In case any other video device is connected such as on board webcam etc the e CAMVi...

Страница 8: ...e Still Capture Pin to select various still image resolutions supported by the device Freeze frame freeze the preview The details of each of these options are described below 6 2 1 Video Capture Filte...

Страница 9: ...ased by increasing the gain of the camera and hence at higher gain values higher brightness values the camera image noise will also be very high and can be easily noticed Figure 4 Brightness full in l...

Страница 10: ...x The frame rate supported by the current resolution will appear in the Frame Rate text box Currently See3CAM_CU51 supports one format 1 Y16 format 640 x 480 binned from 5 MP at 54 fps in USB 3 0 and...

Страница 11: ...ion can be taken from any preview resolution The e CAMView application will save the images in RAW format RAW format in the user specified location To change the resolution the user can select any one...

Страница 12: ...be used to freeze the current previewing frame This can be done by clicking on the Freeze Frame option from the Options menu To resume the normal preview the user should uncheck the Freeze Frame opti...

Страница 13: ...the images will be saved By default the e CAMView will set the Desktop as the image storage path for easy access but the user can change to any location by using the still path option To take an image...

Страница 14: ...can be used to see the current firmware version To select the Master mode click on the MASTER MODE button and click OK Similarly to select the Trigger mode click on the TRIGGER MODE button and click...

Страница 15: ...olled through extension unit menu and will be applied when the image is captured The still image pin can be configured for the required still capture resolution The still image capture can be done in...

Страница 16: ...on the GPIO connector and the camera will start exposing on the trigger signal The external trigger pulse on the GPIO connector must have a pulse duration equal to that of the required exposure so the...

Страница 17: ...06 August 2015 www e consystems com Subject to change without notice Page 17 of 21 6 5 Help Menu The Help Menu can be used to obtain the current version information of e CAMView application installed...

Страница 18: ...p 7 2 Selecting image properties Once the application is installed the user can open the image by double clicking it Irfanview will show a property page indicating the properties to be selected In thi...

Страница 19: ...See3CAM_CU51 Application User Manual 06 August 2015 www e consystems com Subject to change without notice Page 19 of 21 Figure 12 Irfan view properties...

Страница 20: ...6 August 2015 www e consystems com Subject to change without notice Page 20 of 21 8 Comparison of binned VGA and FULL FOV 5MP This comparison shows the FOV conservation in binned VGA Figure 13 VGA Ful...

Страница 21: ...e Page 21 of 21 Figure 14 5MP Full FOV Image Resized to fit in document 9 Conclusion This document provides the basic steps involved in using the e CAMView application and See3CAM_CU51 in the appropri...

Отзывы: