Table 22 

7 segment display 

1st 2nd 

after pressing 
PB3 twice 

after pressing 

PB2 
progressively  

 
Description 

88

 

1

st

 

press:

 

Flame current 

88

 

2

nd

 

press: Modulation level 

88

 

3

rd

 

press: DHW flow frequency 

88

 

4

th

 

press: Flue temperature  

               (for room sealed type, it's fixed as 25)

 

88

 

5

th

 

press: TTB calculated value 

P1

 

P2

 

6

th

 

press: Pump control mode  

88

 

7

th

 

press: Room temperature  

               (if a open therm thermostat connected) 

88

 

8

th

 

press: Software version number for main board (CVBC) 

L 2

 

88

 

9

th

 

press: Software version number for user interface (DSP) 

- After the 

10

th

 press PB2, the display goes back to “ 

L 2 ”

 

Level 3 (setting mode)

 

 

- Press PB3 service push-button 3 times, and see  “ 

L 3 ”

 on the 7 segment display. 

- Press PB2 user push-button progressively to reach some parameters detailed in Table 23.  
- The parameters are set by means of the CH potentiometer (P1). The parameters can be increased 
by turning the CH potentiometer clockwise or decreased by turning the CH potentiometer counter-
clockwise. The 7 segment display shows the set value during adjustment. 

 

Table 23 

 

35

7 segment display 

1st 2nd 

after pressing 
PB3  
3 times 

after pressing 

PB2 
progressively  

 
Description 

88

 

1

st

 

press:

 

CH minimum power set point 

88

 

2

nd

 

press: CH maximum power set point 

88

 

3

rd

 

press: Ignition power set point 

88

 

4

th

 

press: Anti-cycling time set point 

F1

 

F2

 

5

th

 

press: DHW ON-OFF flow rate set point 

d 1 
d 2 

6

th

 

press: DHW delay time set point 

88

 

7

th

 

press: OTC curve foot point 

O

1

 

O

8

th

 

press: Outside temperature limiting set point 

P1 
P2 

9

th

 

press: Pump control mode selection 

L 3

 

88 

10

th

 

press: Modulation start point 

T (F/R), if return sensor  

                  existing 

Содержание Fortius

Страница 1: ...bithermic type 24 kW Room Sealed Fan Assisted Gas Combination Boiler bithermic type 24 kW Room Sealed Fan Assisted Gas Combination Boiler monothermic type 28 kW Room Sealed Fan Assisted Gas Combinatio...

Страница 2: ...y Systems Technical Data Main Components Operating Functions GAS TYPE CONVERSION Gas Pressure Adjustments Replacement Of The Burner Injectors Jumper Adjustment ADJUSTMENTS Service Setting Mode Chimney...

Страница 3: ...ith by pass circuit and pump over run Frost Protection System The appliance must be on stand by mode to activate frost protection system Pump Anti sieze Function 3 Way Anti sieze Function in monotherm...

Страница 4: ...3 40 80 230V AC 50Hz 105 8 750x454x340 33 7 II 2H 3 C12x C32 Natural gas LPG 8 4 24 19 2 9 2 26 2 21 2 73 0 96 2 08 20 28 37 3 10 t 34 0 3 10 35 60 0 8 3 40 80 230V AC 50Hz 150 8 750x454x340 39 8 II 2...

Страница 5: ...ar Pressure Relief Valve 9 c Discharge Tap c Discharge Tap 10 d Filling Tap d Filling Tap 11 e Water Pres Sensor e Water Pres Sensor 12 f Water Flow Sensor f Water Flow Sensor 13 14 DHW NTC Sensor Sur...

Страница 6: ...ling Tap 11 e Water Pres Sensor e Water Pres Sensor 12 f Water Flow Sensor f Water Flow Sensor 13 g Plate Heat Exchanger 12 plate g Plate Heat Exchanger 14 plate 14 h DHW NTC Sensor Direct Immersion h...

Страница 7: ...The main board provides all the functionality and safety of the boiler The board was cased by a plastic casing which was mounted on the gas valve The functionality of the board is provided with 2 mic...

Страница 8: ...Wiring Diagrams 7 fig 1a...

Страница 9: ...8 fig 1b...

Страница 10: ...9 fig 1c...

Страница 11: ...valve output 230 Vrac 50mA Diferantial air pressure switch input 12 Vdc 100 kOhm Limit thermostat input 5 Vdc 100 kOhm Water pressure switch input 12 Vdc 100 kOhm Water flow sensor input output 12 4 V...

Страница 12: ...8 sec Pump over run time A for DHW Monothermic Winter mode Monothermic Summer mode 3 way electric valve Bithermic Winter mode Bithermic Summer mode B for CH Winter mode Summer mode 3 sec 5 sec 3 sec T...

Страница 13: ...it thermostat CLOSE temperature 75 C TTB sensor limit temperature in the first 90 sec 100 C TTB sensor limit temperature after the 90 sec 70 95 C GAS VALVE 2 Gas valve controls and modulates the gas f...

Страница 14: ...d in 24 kW boilers while 15 blade burners are used in 28 kW boilers Some of the common specifications of these two burners are shown in the table below Table 6 Burner Injector nozzle diameter for natu...

Страница 15: ...inlet and one water outlet and only the central heating circuit is heated In monothermic types domestic hot water circuit is heated by a second exchanger plate heat exchanger In both heat exchangers...

Страница 16: ...pump pressure relief valve 3 bar discharge tap filling tap water pressure switch and water flow sensor on it The monothermic hydroblock has pump pressure relief valve 3 bar discharge tap filling tap w...

Страница 17: ...fig 5a Bithermic Hydroblock 1 Outlet manifold 2 Inlet manifold 3 By pass pipe 4 Water flow sensor 5 Filling tap 6 Gasket G3 4 G1 2 7 Hall effect sensor 16...

Страница 18: ...Monothermic Hydroblock 1 3 way electric valve 2 Inlet manifold 3 By pass pipe 4 Water flow sensor 5 Filling tap 6 Valve motor 7 Valve motor clip 8 Hall effect sensor 9 Bolt 10 Oring 11 By pass pipe c...

Страница 19: ...s located on the hydroblock and has 3 speed stages The pump has expansion vessel and termomanometer connections and also an automatic air vent on it fig 6 Pump Table 8 Pump Maximum Power 85 W Speed St...

Страница 20: ...on the inlet manifold in monothermic types Table 10 Discharge Tap Hydroblock connection G External thread FILLING TAP 9 The filling tap is for filling the central heating circuit using the domestic w...

Страница 21: ...late Heat Exchanger Hydroblock connection Bolts 2 pieces Plate heat exchanger water inlet outlet onnections O rings 4 pieces fig 10 Plate Heat Exchanger WATER FLOW SENSOR 12 The water flow sensor meas...

Страница 22: ...rface mounted sensors for domestic water and direct immersion sensors for central heating Only direct immersion NTC sensors are used in monothermic types In bithermic models the surface mounted temper...

Страница 23: ...95 0 2 7 125 346 4 2 6 The sensitivity is the percentage change in resistance of the sensing element per o C temperature change at the specified temperature 3 WAY ELECTR C VALVE 14 3 Way electric valv...

Страница 24: ...nabling the boiler to operate again after the reset In bithermic types limit thermostat is mounted on the heat exchanger with a metal clip while in monothermic types it is mounted using two screws fig...

Страница 25: ...air pressure switch is connected to terminals 1 and 3 2 not connected Table 16 Differential Air Pressure Switch Interior diameter of silicon hose to fan 5 mm Interior diameter of silicon hose to comb...

Страница 26: ...5714 4 7 20 12493 4 5 25 10000 4 4 30 8056 4 3 35 6530 4 2 40 5327 4 0 45 4370 3 9 50 3603 3 8 55 2986 3 6 60 2488 3 6 65 2083 3 5 70 1752 3 4 75 1480 3 3 80 1255 3 3 85 1070 3 3 90 915 3 2 95 787 3 1...

Страница 27: ...displays the water temperature and water pressure of the central heating circuit IGNITION ELECTRODE 21 The burner is ignited by a spark between two ignition electrodes One of the electrodes is earthe...

Страница 28: ...or Conditions like sensor faults or over temperature The priority of the modes of functions is as follows 1 Fault Error Condition 2 Service Settings Mode 3 DHW Mode 4 CH Mode 5 Frost Protection 6 Stan...

Страница 29: ...hot water tap and open it again b In Bithermic types if the boiler is in summer mode the burner will switch OFF and to reactivate DHW mode again it is necessary to close the hot water tap and open it...

Страница 30: ...nsor detects temperature less then 6 C CH mode is activated burner starts As long as frost protection conditions last till water temperature reaches 30 C the burner operates in minimum capacity When t...

Страница 31: ...od of time 10 min If the boiler is switched to summer mode when CH mode is active pump over run time is 5 sec Pump Anti Seize Function 5 The pump may be blocked if not used for a long period of time T...

Страница 32: ...ed on the lower edge to remove the front panel Undo the 2 screws which are located on the corners of the control panel Pull the control panel outwards to reach the gas valve Maximum operating pressure...

Страница 33: ...o remove the combustion body cover in room sealed fan assisted boiler Undo the 4 screws which fasten the manifold to the burner to remove the burner Fix the suitable burner injectors according to type...

Страница 34: ...type conversion GAS LEAK TEST Apply a rich soap and water solution to the surface of all pipe connections Bubbles indicate a gas leak In case of gas leak tighten the pipe connection Check the pipe con...

Страница 35: ...oiler parameters Level 3 L3 is setting mode to set some boiler parameters Level 4 L4 is fault history and permits to read the last 8 error codes While in service level LED L7 is on fig 20 Service leve...

Страница 36: ...button progressively to reach some parameters detailed in Table 23 The parameters are set by means of the CH potentiometer P1 The parameters can be increased by turning the CH potentiometer clockwise...

Страница 37: ...ow rate ltr min can be adjusted as F1 ON 3 OFF 2 5 or F2 ON 3 5 OFF 3 DHW Delay Time In order to avoid water hammer effect in DHW mode DHW delay time can be adjusted as d2 1 sec or it can be adjusted...

Страница 38: ...Mode 1 11 Pump control mode P2 Mode 2 P2 12 Modulation start point T F R if return sensor existing o C 10 30 20 Level 4 fault history 3 Press PB3 service push button 4 times and see L 4 on the 7 segme...

Страница 39: ...ed by pressing the push button again more than 3 seconds and less than 5 seconds fig 21c If chimney sweep mode is started in stand by mode the system goes back to stand by mode after the deactivation...

Страница 40: ...nk OFF fast blink fig 22b Turn the CH potentiometer the maximum position LED L8 and L9 start blinking to indicate that maximum running is being selected fig 22c The appliance operates in max load with...

Страница 41: ...call qualified service While in lockout conditions LED L2 will turn on b Blocking conditions Circuit break in flue safety device NTC Short circuit in flue safety device NTC Flue safety device NTC shut...

Страница 42: ...r temperature failure E 3 Flow temperature too high t 1 Circuit break in CH flow sensor NTC t 3 Short circuit in CH flow sensor NTC t 3 Circuit break in DHW sensor NTC t 5 Short circuit in DHW sensor...

Отзывы: