INFORMATION
The appliance should not be used above 2000m altitude above sea level.
Installation
INFORMATION
Com
m
issioning
Operation and Maintenance
3
- Please be wary of the warnings in the installation and user manual. That way, any danger caused
by false operation could be prevented.
- For the longevity and high performance of your appliance, maintenance once a year is advised.
Maintenance is under the scope of appliance’s warranty and must be done by the authorized
E.C.A. technical services.
- Outer surfaces of the appliance must be cleaned with a damp cloth without using any chemical
substances. Usage of chemicals like detergents etc. could cause rust and scratches.
Do not install the appliance where it will be affected by direct sunlight. Sun
beams can cause discoloration on the outer surfaces of the appliance.
- Installation of this boiler must be done by a authorized technical service according to the
informa-tion (placement, flue connections etc.) presented on related standards and authorized gas
companies. After the installation, installer must make sure that user has been given the user
manual and give all the necessary information about the boiler and related safety equipments.
- Boiler must be installed in a manner that the appliance should not be in direct contact with water
vapor, detergent vapor or similar chemicals.
- Flue connections must not be tampered with without consulting to the authorized technical
service.
- Siphon included in the appliance package must be mounted to the siphon lid underneath the
appliance.
- First startup of the appliance must be done by the authorized service. Natural gas usage must be
approved by the related gas company prior to the first startup.
- The gas type (natural gas), inlet gas pressure (mbar), maximum water pressure (bar) and
electrical nominal voltage (V) values on the information label must be checked with the local
conditions.
- To prevent the risk of flue gas leakage to the environment, condensing siphon must be filled with
water prior to flue connection.
- After the installation of the appliance, please ask your authorized service personnel to give
information about the operation and safety equipments of the appliance.
- Tightness rubbers (EPDM) on the flue connections must be lubricated prior to the installation.
Grease oil and machine oils shall not be used under any circumstance.
CAUTION:
If the appliance will not be in use until winter season,
water inside the boiler should be drained to prevent freezing.
All data regarding the cascade installation can be seen from the control panel of the master
appliance, therefore slave appliances don’t need to have a separate control panel. LEDs on the
appliances indicate error states and burning statuses. If a single appliance falls into an error state,
error code and the appliance address can be seen from the control panel of the master appliance
and the error can be reset from the button on the aforementioned slave appliance.
To install this appliance in a cascading system, there are suitable cascade accessories available. In
cascade applications, required accessories are subject to change by the requirements of the
actual application. Please contact the manufacturer or your seller for more information.
Содержание FELIS FL 100 HM
Страница 1: ...FELIS WALL HUNG CONDENSING BOILER FELIS FL 50 65 100 125 150 HM INSTALLATION AND USER MANUAL ...
Страница 2: ......
Страница 10: ...7 Felis 65 Figure 2b Felis 65 Detailed Drawings ...
Страница 11: ...8 Felis 100 125 150 Figure 2c Felis 100 125 150 Detailed Drawings ...
Страница 13: ...Figure 3 Electronic Board Circuit Diagram 10 Electrical Board Circuit Diagram ...
Страница 18: ... d d l Figure 7 Flue Types 15 I I I I ...
Страница 30: ...27 ...
Страница 31: ...28 ...
Страница 32: ...29 ...
Страница 33: ...30 ...
Страница 40: ......
Страница 46: ......