Prise the grommet out of the inner bucket
with a thin screwdriver.
service manual
Issued 10/06
31
Fitting notes
The crevice tool clip can be pushed out of
the side of the duct with a screwdriver and a new
one pressed back in place.
Firmly prise the wand release catch and
spring out of the top of the duct if necessary
using a large flat bladed screwdriver.
Firmly press the wand release catch and
spring under the ribs on the rear of the duct.
Push the catch into position until it clips into
place.
The micro switch loom assembly, cleaner
head coiled cable loom assembly or internal
cable assembly can be replaced. Carefully
release the relevant wires from the channel and
detach.
141
142
140
139
138
When fitting any one of the assemblies,
ensure all wires are neatly dressed into the base
of the inner bucket and the grommets are
correctly located under the retaining ribs.
143
Sub-assemblies - internal cable
looms assembly