Dynorbital-Spirit 59000 Скачать руководство пользователя страница 2

To Tool Station

Closed Loop Pipe System

(Sloped in the direction of air flow)

Ball

Valve

Ball

Valve

Filter

Coupler

Regulator

Lubricator

Air Flow

Drain
Valve

Drain
Valve

Air Tool

Air Compressor

and Receiver

Drain Valve

Air Hose

90 PSIG MAX

(6.2 Bar)

Air Flow

Refrigerated

Air Dryer

2

Filter

Regulator

Lubricator

90 PSIG

(6.2 Bar)

OPERATING INSTRUCTIONS (continued)

• Keep hand and clothing away from working end of the air tool.

Operation:  Be sure that any loose clothing, hair and all jewelry is properly restrained.

• Secure inlet bushing on air tool with a wrench before attempting to install the air fitting to avoid damaging housing assembly.
• Check tool RPM (speed) with tachometer with air pressure set at 90 PSIG while the tool is running.  If tool is operating at a higher speed than the RPM marked on the tool 

housing, or operating improperly, the tool must be serviced and corrected before use.

Caution: Tool RPM must never exceed abrasive/accessory RPM rating.  Check accessory manufacturer for details on maximum operating speed or special

mounting instructions.

• With power source disconnected from air tool, mount recommended accessory into collet assembly.
• Connect air tool to power source.  Be careful NOT to depress throttle lever in the process.  Do not expose air tool to inlet pressure above 90 PSIG or (6.2 Bars).

Caution: After installing the accessory, before testing or use and/or after assembling tool, the Dynorbital-Spirit™ must be started at a reduced speed to check for good

balance.  Gradually increase tool speed.  DO NOT USE if tool vibration is excessive.  Correct cause, and retest to insure safe operation.

• Make sure that work area is uncluttered, and visitors are at a safe range from the tools and debris.
• Use a vise or clamping device to hold work piece firmly in place.
• Do not apply excessive force on tool or apply “rough” treatment to it.
• Always work with a firm footing, posture and proper lighting.

Report to your supervisor any condition of the tool, accessories, or operation you consider unsafe.

Air System

1

DROP/MIN.

20

SCFM

LUBRICATOR SETTING

Ideally the air supply should be free from moisture.
Incorporating a refrigerated air dryer after the
compressor and drain valves at each tool station
(as shown) further reduces moisture from
condensation in the air supply.

Dynabrade Air Power Tools are designed to
operate at 90 PSIG (6.2 Bar/620 kPa) maximum
air pressure at the tool inlet, when the tool is
running.  Use recommended regulator to control
air pressure.

Содержание 59000

Страница 1: ...3 16 Orbit 3 32 Orbit 59000 59010 59015 59025 59030 59040 59001 59011 59016 59026 59031 59041 59002 59012 59017 59027 59032 59042 59003 59013 59018 59028 59033 59043 59004 59014 59019 59029 59034 59044 59005 59100 59020 59105 59035 59110 59006 59101 59021 59106 59036 59111 59007 59102 59022 59107 59037 59112 59008 59103 59023 59108 59038 59113 59009 59104 59024 59109 59039 59114 FOR COMPLETE MODEL...

Страница 2: ...into collet assembly Connect air tool to power source Be careful NOT to depress throttle lever in the process Do not expose air tool to inlet pressure above 90 PSIG or 6 2 Bars Caution After installing the accessory before testing or use and or after assembling tool the Dynorbital Spirit must be started at a reduced speed to check for good balance Gradually increase tool speed DO NOT USE if tool v...

Страница 3: ...ice Below DO NOT carry tool by air hose Protect abrasive accessories from exposure to water solvents high humidity freezing temperature and extreme temperature changes Store accessories in protective racks or compartments to prevent damage Notice All Dynabrade motors use the highest quality parts and materials available and are machined to exacting tolerances The failure of quality pneumatic motor...

Страница 4: ...17 59018 59019 59020 59059 59022 59023 59024 59025 59026 59027 59028 59029 59030 59031 59032 59033 59034 59035 59036 59037 59038 59039 59040 59041 59042 59043 59044 59100 59101 59102 59103 59104 59105 59106 59107 59108 59109 59110 59111 59112 59113 59114 18 26 29 1 Sanding Pads See Pg 10 2 Vacuum Lip Seal Shroud 57089 5 6 3 Vacuum Shroud 57084 3 1 2 4 Shroud Non Vac 54458 3 1 2 56051 5 6 Lip Seal ...

Страница 5: ...gh the central vacuum adapter 3 Place muffler cap with inserts on muffler body making sure that the protrusions on the body fit in the pockets on the cap 4 Attach weight mated vacuum sanding pad with 50679 26 mm Open End Wrench Attach machine to central vacuum system Self Generated Vac to Central Vac 1 Remove 96197 Dowel Pin with an 1 8 drive pin Remove 57067 Vacuum Tube from 57083 Vacuum Adapter ...

Страница 6: ...o protect the housing slide the drop in air motor into the housing aligning the line up post with the notch on the inside of the housing Note Make certain that the line up post enters the notch in the housing and that the 01024 O Ring remains seated in the side of the cylinder 4 Tighten the lock ring with the 56058 Lock Ring Wrench Torque to 23 N m 200 in lbs 5 Install a Dynabrade weight mated san...

Страница 7: ...ing the slider weight pull the assembly out c Press off 56052 Bearing with a bearing separator and arbor press remove 59084 V Seal 12 If during step 11 the 56052 Bearing remains in the motor shaft balancer it can be removed by the heating the shaft balancer again and using either an inside bearing puller or a blind hole bearing puller To Assemble Important Clean and inspect all parts for defects b...

Страница 8: ...new 95967 Snap Ring Apply a small amount of pneumatic tool oil to valve o rings 5 Place new 01464 Seal in housing Using tweezers or needle nose pliers place the tip valve into housing so that the tip valve goes under the valve stem Place new 01468 Spring into housing so small end is towards tip valve 6 Apply a small amount of 567 Loctite or equivalent around the threads of the first inlet bushing ...

Страница 9: ...pter 1 X 8 56027 Muffler Inserts 2 T X 9 56028 Muffler Cap 1 T L Drop in Motors Allows a quick and easy replacement No motor adjustments needed 59450 3 3 1 2 Dia 3 8 Orbit 59451 3 3 1 2 Dia 3 16 Orbit 59452 3 3 1 2 Dia 3 32 Orbit 59453 5 Dia 3 8 Orbit 59454 5 Dia 3 16 Orbit 59455 5 Dia 3 32 Orbit 59456 6 Dia 3 8 Orbit 59457 6 Dia 3 16 Orbit 59458 6 Dia 3 32 Orbit Complete Repair Solution Includes ...

Страница 10: ...owing for quick removal of used discs Special rubber vinyl face pads for PSA discs Post Pattern design for enhanced vacuum pick up Unique vinyl surface pads provide excellent disc adhesion allowing for quick removal of used discs No need to align vacuum holes saves time on disc changes Hook face short nap pads for reattachable discs 3 1 2 5 and 6 diameter disc pads have 5 16 24 male threaded stud ...

Страница 11: ...ong cloth cover Covers air line and exhaust vacuum hoses not included Eliminates damage from hoses dragging on the workpiece 54290 Bag in Box System 95361 Air Line 5 long 50682 Flex Hose 1 dia x 6 long 95362 Rubber Connectors 5 attach air line to vacuum hose 95575 Durable Box Receptacle to house bag and store tool Sample paper bag included Paper bag reorder 50692 400 case or 50693 24 per package 5...

Страница 12: ...2 5 16 24 female 1 4 0 6 7 178 3 1 2 89 59020 25 186 12 000 3 16 5 75 dB A 2 16 453 90 6 2 5 16 24 female 1 4 0 6 6 1 2 165 3 1 2 89 59021 59022 59023 25 186 12 000 3 16 5 80 dB A 2 16 453 90 6 2 5 16 24 female 1 5 0 7 8 1 2 216 3 1 2 89 59024 25 186 12 000 3 16 5 77 dB A 2 16 453 90 6 2 5 16 24 female 1 5 0 7 7 1 4 184 3 1 2 89 59025 25 186 12 000 3 16 5 75 dB A 2 16 453 90 6 2 5 16 24 female 1 5...

Отзывы: