14
TE
CHNICAL
D
A
TA
Alarm Setpoints
2 High and 2 Low user-setable alarm points.
Configured and transmitted via DeviceNet protocol.
Include user-defined hysteresis band.
3.13
3.13
3.13
3.13
3.13
E
E
E
E
E
NGINEERING
NGINEERING
NGINEERING
NGINEERING
NGINEERING
U
U
U
U
U
NITS
NITS
NITS
NITS
NITS
Counts
Analog to Digital Counts
o to 20000 typical
PSI
pounds-force per square inch
14.503774*bar
BAR
bar
(Full Scale Bar)/(Full Scale Counts)*Counts
kgf/cm
2
kilogram-force per square centimeter
1.0197162*bar
MPa
MegaPascal
0.1*bar
% Full Scale
Percent full scale
0 to 100
3.14
3.14
3.14
3.14
3.14
S
S
S
S
S
ENSOR
ENSOR
ENSOR
ENSOR
ENSOR
D
D
D
D
D
IAGNOSTICS
IAGNOSTICS
IAGNOSTICS
IAGNOSTICS
IAGNOSTICS
Overrange Notification
Yes
CPU Watchdog Error
Yes
EEPROM Failure
Yes
Open Gauge Detection
Yes
Electronics Temperature Detection
Yes
3.15
3.15
3.15
3.15
3.15
P
P
P
P
P
ERFORMANCE
ERFORMANCE
ERFORMANCE
ERFORMANCE
ERFORMANCE
CHARACTERISTICS
CHARACTERISTICS
CHARACTERISTICS
CHARACTERISTICS
CHARACTERISTICS
3.15.1
3.15.1
3.15.1
3.15.1
3.15.1
C
C
C
C
C
OMBINED
OMBINED
OMBINED
OMBINED
OMBINED
E
E
E
E
E
RROR
RROR
RROR
RROR
RROR
(A
(A
(A
(A
(A
C
C
C
C
CC
C
C
C
CURA
URA
URA
URA
URACY
CY
CY
CY
CY
)))))
Combined error is also known as accuracy which includes linearity, hysteresis and repeatability, and is
determined by BFSL (Best Fit Straight Line).
±0.5% of full scale
±0.75% of full scale for transmitters with ranges of 1000 psi and less with lengths greater than 36”.
3.15.2
3.15.2
3.15.2
3.15.2
3.15.2
R
R
R
R
R
EPEA
EPEA
EPEA
EPEA
EPEAT
TT
TTABILIT
ABILIT
ABILIT
ABILIT
ABILITY
Y
Y
Y
Y
±0.20% of full scale
Содержание PT460DN
Страница 38: ...38 CE DECLARATION...