STEP 6 - Option 2: Install on a solid concrete or concrete block
wall
You’ll need
1
Align the wall plate (
A
) at the height you determined in the previous step, make
sure that it is level, then use a pencil to mark the lag bolt hole locations (4). Remove
the wall plate (
A
).
2
Drill pilot holes to a depth of 2.36 in. (60 mm) using a 3/8 in. (10 mm) diameter
masonry drill bit.
CAUTION:
To prevent property damage or personal injury, never drill into mortar
between blocks. Mount the wall plate directly onto the concrete surface.
P
(4)
Pencil
Drill
1/2" socket wrench
Level
O
(4)
Wall plate (
A
)
Q
(4)
3/8 in. masonry drill bit
Concrete
wall
2.36 in. (60 mm)
3/8 in.
(10 mm)
* Minimum solid concrete thickness: 8 in. (203mm).
* Minimum concrete block size: 8 x 8 x 16 in. (203 x 203 x 406 mm).
The minimum distance between the top two fasteners cannot be less than 16 in. (40 cm)