Installing your UPS

3

Installing your UPS

You can use your UPS immediately. The first time you plug in your UPS, 
turn it on and leave it connected to AC power for at least 16 hours to fully 
charge the battery. 

To install your UPS:

1

Before you plug in and turn on your UPS, plug your computer, 
monitor, and external storage devices into the battery-powered 
outlets on your UPS.
Plug your other devices into the surge-protected outlets.

Caution:

 Do not plug a laser printer, paper shredder, copier, 

space heater, vacuum, or other large electrical devices into your 
UPS. The amount of electricity used by these types of devices 
could overload and possibly damage your UPS.

2

If you have a network connection, plug the network cable into the 
IN communication jack on your UPS, then plug the telephone 
cable into the OUT communication jack on your UPS.

3

Plug your UPS into a 2-pole, 3-wire grounded electrical outlet. 
Make sure that the electrical outlet is protected by a fuse or circuit 
breaker and that the fuse or breaker does not provide electricity to 
equipment with large electrical demands. 

Caution:

Do not plug your UPS into an extension cord, outlet 

strip, or surge protector.

4

Press the power switch on your UPS. The power indicator turns on 
and your UPS beeps one time.

Caution:

If your UPS detects an overload, your UPS sounds an 

audible alarm and makes one long beep. To correct this problem, 
turn off your UPS, then unplug at least one piece of equipment 
from the battery-powered outlets. Wait 10 seconds. Make sure 
the circuit breaker is depressed, then turn on your UPS.

Note:

 To maintain optimal battery charge, leave the UPS plugged 

into an AC outlet at all times.

Note:

 To store your UPS for an extended period, cover it and store 

it with the battery fully charged. If you store it for an extended 
period of time, recharge the battery every three months to make 
sure that the battery retains a charge.

Mounting your UPS on a wall

To mount your UPS on a wall:

1

Locate a stud on the wall you want to mount your UPS on.

2

Insert one screw into the center of the stud.

3

Insert a second screw 5 5/8 inches from the first screw.

4

Align the mounting holes on the back of your UPS with the screws, 
then slide the UPS over the screw heads.

Installing PowerPanel™ Personal Edition 
software

Your UPS comes with PowerPanel Personal Edition software that lets you 
monitor your UPS from your computer.

To install the PowerPanel Personal Edition software:

1

Insert the PowerPanel Personal Edition CD in your disc drive. The 
setup program opens automatically.

2

Follow the on-screen instructions to install the software.

3

See the PowerPanel Personal Edition online help for information 
about using the software.

Status indicators

Your UPS has two LED indicators and one audible alarm to let you know 
the status of your UPS.

10 Vertical stand

Position this end of your UPS on the bottom 
so you can stand your UPS vertically.

11 COAX/Cable/DDS 

jacks

Plug your DSL or cable modem, CATV 
converter, or DSS receiver into these jacks.

Component

Description

Power 
On

P

Wiring 
Fault

Audible 
Alarm

Condition

On

Off

Off

Normal

On

On/Off

Two 
beeps

Power failure has occurred. 
Your UPS is supplying power to 
plugged in devices.

On

On/Off

Rapid 
beeps

The UPS battery charge is low.
Power failure has occurred. 
Your UPS is supplying power to 
plugged in devices.

1/8"

Max. 5/16"

1 1/4"

(3.175 mm)

(6.35 mm)

(7.938 mm)

R

ECOMMENDED

 

SCREW

 

DIMENSIONS

Screw

Wall stud

5 5/8"

(150.0 mm)

W

ALL

 

MOUNT

Dynex-DX-800U UPS.fm  Page 3  Tuesday, July 26, 2005  6:07 PM

Содержание DX-800U

Страница 1: ...UIDE DE L UTILISATEUR GUÍA DEL USUARIO UPS Battery Backup System Onduleur avec système de batterie de sauvegarde UPS Sistema de respaldo por batería DX 800U Dynex DX 800U UPS fm Page 1 Tuesday July 26 2005 6 07 PM ...

Страница 2: ... parts inside except for the battery Even if your UPS is not plugged into an electrical outlet electrical energy may still flow through your UPS from the battery Your UPS must be connected to an AC power outlet that has fuse or circuit breaker protection Do not plug into an ungrounded outlet If you need to de energize your UPS turn it off and unplug it Package contents Inspect the UPS upon receipt...

Страница 3: ...et at all times Note To store your UPS for an extended period cover it and store it with the battery fully charged If you store it for an extended period of time recharge the battery every three months to make sure that the battery retains a charge Mounting your UPS on a wall To mount your UPS on a wall 1 Locate a stud on the wallyou want to mount your UPS on 2 Insert one screw into the center of ...

Страница 4: ...rtment cover completely off of your UPS 6 Remove the battery from the compartment 7 Disconnect the battery wires from the battery Note which wire is connected to the positive and negative terminals of the battery 8 Install the replacement battery by connecting the red wire and black wire to the positive and negative terminal of the battery 9 Put the battery back into the compartment 10 Slide back ...

Страница 5: ...e gray The USB or serial cable is not connected The USB or serial cable is connected to the wrong port Your UPS is not providing battery power The serial cable is not the cable that was included with your UPS Connect the USB or serial cable to your UPSunit and an open USB or serial port on the back of the computer You must use the cable that came with your UPS Check the back of the computer for an...

Страница 6: ...rter à Specifications pour la gamme de température et d humidité acceptable Afin de réduire le risque de choc électrique ne pas enlever le couvercle sauf pour changer la batterie Il n existe aucune pièce réparable par l utilisateur à l intérieur à l exception de la batterie Même si l onduleur n est pas branché à une prise électrique de l énergie électrique peut quand même circuler à travers l ondu...

Страница 7: ... des équipements des prises alimentées par la batterie Attendre 10 secondes S assurer que le disjoncteur est enclenché puis remettre l onduleur sous tension Remarque Afin que la batterie soit chargée de façon optimale laisser l onduleur branché dans une prise CA en permanence Remarque En cas de rangement de l onduleur pour une durée indéterminée le couvrir et le ranger avec la batterie totalement ...

Страница 8: ...dont la poignée est isolée Ne pas poser d outils ou pièces métalliques sur la batterie ou les bornes Porter des gants en caoutchouc et des chaussures Déterminer si la batterie a été mise à la terre par inadvertance Si elle est mise à la terre enlever la source de la terre Le contact avec une batterie mise à la terre peut provoquer un choc électrique Remplacement de la batterie 1 Mettre hors tensio...

Страница 9: ...un appareil Attendre 10 secondes réenclencher le disjoncteur puis remettre l onduleur sous tension La batterie n alimente pas aussi longtemps que prévu La batterie est déchargée La batterie est usée Recharger la batterie Remplacer la batterie L onduleur ne peut pas être mis sous tension L onduleur n est pas branché L interrupteur de marche arrêt est conçu pour éviter des dommages s il est basculé ...

Страница 10: ...ón del paciente No utilice este aparato cerca del agua Condensación delacuario puede causar que su UPS haga cortocircuito y cause un incendio o choque eléctrico Paraevitarchoques eléctricos apague su UPS ydesconéctela de la fuente de alimentación de CA antes de reemplazar la batería o instalar un componente de computadora Para prevenir el riesgo de incendio o choque eléctrico instálela en un área ...

Страница 11: ...ería por ejemplo una computadora unmonitoroundispositivode almacenamiento externo Éstas proveen protección contra sobrevoltaje y a su vez proveenalimentación con respaldo por batería Si una falla de energía ocurre estos tomacorrientes proveenalimentación a los dispositivos 2 Tomacorrientes con protección contra sobrevoltaje Estos tomacorrientes son para conectar dispositivos que no necesitan alime...

Страница 12: ... ayudaen línea del PowerPanelPersonalEditionpara obtener información sobre como usar el software Indicadores de estado Su UPS tiene dos indicadores LED y una alarma audible que le hacen saber del estado de su UPS 1 8 Max 5 16 1 1 4 3 175 mm 6 35 mm 7 938 mm DIMENSIONES DE LOS TORNILLOS RECOMENDADOS tornillo viga de pared 5 5 8 150 0 mm SOPORTE DE PARED Encendid o P Falla de cableado Alarma audible...

Страница 13: ...o cualquier terminal Use guantes y botas de caucho Determinesilabateríaestaconectadaatierrasinqueustedse de cuenta Si esta conectada a tierra remueva la conexión a tierra Ponerse en contacto con una batería conectada a tierra puede resultar en choque eléctrico Para reemplazar la batería 1 Apagar y desconectar los dispositivos conectados 2 Apague el UPS y desconéctelo del tomacorriente de CA 3 Volt...

Страница 14: ...ado El cable USB o serial está conectado al puerto incorrecto Su UPS no está proporcionando alimentación por batería El cable serial no es el cable que fue suministrado con su unidad Conecte el cable USB o serial a la unidad del UPS y a un puerto USB o serial disponible situado en la parte posterior de la computadora Se debe usar el cable suministrado con su UPS Revise la parte posterior de la com...

Страница 15: ...C 7601 Penn Ave South Richfield MN 55423 U S A Distribué par Best Buy Purchasing LLC 7601 Penn Ave South Richfield MN 55423 É U Distribuido por Best Buy Purchasing LLC 7601 Penn Ave South Richfield MN 55423 U S A R1 Dynex DX 800U UPS fm Page 15 Tuesday July 26 2005 6 07 PM ...

Отзывы: