background image

Model

Voltage/

Frequency

Region

(Plug)

Capacity

Gallon (Liter)

61400

120/60 Hz

US/Canada, 20 Amp

24 (90)

61420

120/60 Hz

US/Canada, 15 Amp

24 (90)

61402

230/50 Hz

UK

24 (90)

61408

230/50 Hz

CEE7

24 (90)

61412

230/50 Hz

Switzerland

24 (90)

Raptor Vac

Non-Conductive

Dry, Electric Portable Vacuum Systems

“M” CLASS DRY VACUUM

When employed in accordance with their
intended use, the industrial vacuum cleaners
described in these operating instructions are
suitable for picking up non-flammable, dry dusts.
They correspond to dust class “M” in accordance
to: 

EN 60335-2-69. By ILK, Germany

FOR COMMERCIAL USE

Содержание Raptor Vac

Страница 1: ...61412 230 50 Hz Switzerland 24 90 Raptor Vac Non Conductive Dry Electric Portable Vacuum Systems M CLASS DRY VACUUM When employed in accordance with their intended use the industrial vacuum cleaners described in these operating instructions are suitable for picking up non flammable dry dusts They correspond to dust class M in accordance to EN 60335 2 69 By ILK Germany FOR COMMERCIAL USE ...

Страница 2: ...Do not use outdoors or on wet surfaces ...

Страница 3: ...n doubt as to whether the outlet is properly grounded Do not modify the plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician Make sure that the appliance is connected to an outlet having the same configuration as the plug No adaptor should be used with this appliance This appliance is for use on a nominal 120 Volt circuit snd a gr...

Страница 4: ...f them 13 Return Motorhead Vacuum Head Assembly to the unit and lock the twor rim clamps to secure Motorhead Vacuum Head Assembly in position 14 Connect your Dynabrade air tool or accessory and you are now ready for working with the Dynabrade Portable Vacuum System THIS IS A PRECISION PIECE OF EQUIPMENT designed for dust extraction to keep your ENVIRONMENT and your REPUTATION DUST FREE Read operat...

Страница 5: ...ll resume operation REMOVAL INSTALLATION OF MOTORHEAD FROM MAIN ASSEMBLY If the filter element becomes clogged or to clean the inner portions of the drum canister the Motorhead Assembly must then be removed to perform cleaning When removal becomes necessary for cleaning or other service follow the procedures described below Removal 1 Unplug the unit before attempting service or maintenance work 2 ...

Страница 6: ...Cover Bottom 80467 28 Washer 80420 29 Screw 80418 30 Clamp 80173 31 Sleeve 80472 32 Check Valve 80446 33 Electrovalve 120 V Electrovalve 230 V 80458 80490 34 Connector 80449 35 Elbow 80447 36 Tube per Meter 80401 37 Pressure Reducer 80439 38 Washer 80420 39 Elbow 80447 40 Reducer 80434 41 Valve 80436 42 Connector 80435 43 Air Tank 80432 44 Safety Valve 80437 45 Tube 80438 46 Guide 80405 47 Gasket ...

Страница 7: ...Connector 80433 7 Nipple 80400 8 Sensor Body 80476 9 Sensor Plate 80227 10 Sensor 80241 11 O Ring 80226 12 Screw 80228 13 Nipple 80220 14 Washer 80221 15 Y Connector 96571 16 Tube per Meter 80453 17 Coupling 80222 18 Guide 80421 19 Bracket 80231 20 Screw 80225 Pneumatic Tool Supply Line Complete Assembly 1 ITEM DESCRIPTION P N 1 HEPA Filter 80459 Filter ...

Страница 8: ... 24 Conductive Y Inlet 31968 Coaxial Vacuum Hose Assy 94941 COAXIAL VACUUM HOSE ASSEMBLY QTY 2 PART NO 94941 1 1 4 DIA X 20 32 MM X 6M Cuff P N 95800 Cuff P N 95800 P N 96394 P N 96394 Swivel Adapter P N 96573 43 m Length 1 1 4 32 mm Vac Hose P N 54461 5 1 m Length 1 1 4 32 mm Vac Hose P N 96420 43 m Length 1 1 4 32 mm Vac Hose P N 54461 Cuff with Air Line Exit Cuff with Air Line Exit Air Line Ass...

Страница 9: ...M Symbol of hazardous dust collection WARNING These symbols will be used to remind the operator to pay attention to operations that may cause lesions includ ing death to the operator or to other people or animals nearby Furthermore the operations indicated by these symbols may cause damages even irreparable ones to the suction device ATTENTION Please read carefully the instruction manual before us...

Страница 10: ... danger therefore it must be avoided WARNING Operators must be properly trained for using these machines WARNING Only for indoor application WARNING This appliance must be stored taking its weight into considera tion on a solid steady safe and not sloping plane indoor and in moisture free environments WARNING This appliance can be used for suction dry only and it cannot be stored in the open or un...

Страница 11: ...ke sure that the values indicated on the technical data label correspond to those of the network to which you intend to connect the appliance and that the socket is compatible with the plug Do not pick up materials that can damage the filtering elements such as glass metal etc Do not ever pull or lift the appliance through the electrical cable Don t touch the plug or the appliance with wet hands D...

Страница 12: ...just to prevent risks to maintenance men Before any operation prepare all the appropriate measures for one s personal safety for the safety of others and of the surrounding environment refer to the safety procedures in the work place All the parts of the device must be deemed to be contaminated when they are re moved from the area of use and appropriate action must be taken to prevent dis persal o...

Страница 13: ...container for disposal The user can clean the machine only with a dry cloth NOISE LEVEL Values measured according to EN 60704 1 1997 EN 60704 2 1 2001 rules Measurement A for the sound pressure level of the machine is 73 2 dB A Under unfavorable power conditions the appliance may cause temporary drops in voltage VIBRATION The value of the hand arm vibration on the suction pipe is less than 2 5m s ...

Страница 14: ...leaner motor will switch off IMPORTANT INFORMATION WHEN CONNECTING ELECTRO PNEUMATIC TOOLS TO THE VACUUM CLEANER WARNING The manufacturer is not responsible for damages to people or things due to an incorrect or negligent use of the ELECTRIC REMOTE CON TROL DEVICE WARNING THE ADDITIONAL SOCKET IS ALWAYS UNDER POWER WHEN THE MACHINE PLUG IS CONNECTED TO POWER SUPPLY WARNING BEFORE CONNECTING ELECTR...

Страница 15: ...cleaner B1 WHITE SLIDE SWITCH I II optional POSITION I low speed 1 user 1 flexible hose POSITION II high speed 2 users 2 flexible hoses U ORANGE INDICATOR LIGHT Connected to a pressure switch when it lights means that the cartridge filter essential filter is clogged and it must be replaced U1 RED INDICATOR LIGHT It turns on when the thermal protection that stops the motor is activated The thermal ...

Страница 16: ...08 EMC EN 61000 3 2 2006 A1 2009 A2 2009 EMC EN 61000 3 3 2014 EMC following the provisions of the Directives 2006 42 EC Machinery directive 2004 108 EC Electromagnetic compability EMC 2011 65 EC Directive RoHS II Colin F Brogan Person authorised to compile the technical file DYNABRADE V O H G R 0 in conformity with the following standards or other normative document s declare under our responsibi...

Страница 17: ... Outlets 2 Construction Stainless Steel Drum Canister Remainder Plastic and Metal Components Dust Debris Collection Cloth Bag H E P A 0 3 micron Standard Accessories 2 Pieces of 1 1 4 I D x 20 Long Flexible Vacuum Hose with Built In 3 8 I D Air Supply Tubing Standard Vacuum Hose 2 20 x 1 1 4 Light Weight Coaxial Hose 6M x 32mm Vacuum Control One Tool Two Tool Cord Set 27 8M Discover other power to...

Отзывы: